Microscope-Based Augmented Reality with Intraoperative Computed Tomography-Based Navigation for Resection of Skull Base Meningiomas in Consecutive Series of 39 Patients

被引:18
|
作者
Pojskic, Mirza [1 ]
Bopp, Miriam H. A. [1 ,2 ]
Sass, Benjamin [1 ]
Carl, Barbara [1 ,3 ]
Nimsky, Christopher [1 ]
机构
[1] Univ Marburg, Dept Neurosurg, D-35037 Marburg, Germany
[2] Marburg Ctr Mind Brain & Behav CMBB, D-35032 Marburg, Germany
[3] Helios Dr Horst Schmidt Kliniken, Dept Neurosurg, D-65199 Wiesbaden, Germany
关键词
augmented reality; skull base surgery; skull base meningioma; intraoperative computed tomography; neuronavigation; REGISTRATION; SURGERY; NEURONAVIGATION;
D O I
10.3390/cancers14092302
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary The aim of surgery for skull base meningiomas is maximal resection with minimal damage to the involved cranial nerves and cerebral vessels. Compared to non-skull base meningiomas, these lesions show a reduced rate of gross total resection (GTR). Therefore, the use of technologies for improved orientation in the surgical field, such as neuronavigation and augmented reality (AR), is of interest. We confirmed in a consecutive series of 39 patients who underwent surgery for skull base meningiomas that automatic registration with intraoperative computed tomography (iCT) showed high registration accuracy and that microscope-based AR largely facilitated the resection by increasing surgical precision and providing improved intraoperative orientation by visualizing the tumor and the critical neurovascular structures in the operative microscope. No injuries to critical neurovascular structures occurred. There were 26 patients (66.6%) who underwent GTR. Additionally, 33 out of 35 patients who lived to follow-up could ambulate. Background: The aim of surgery for skull base meningiomas is maximal resection with minimal damage to the involved cranial nerves and cerebral vessels; thus, implementation of technologies for improved orientation in the surgical field, such as neuronavigation and augmented reality (AR), is of interest. Methods: Included in the study were 39 consecutive patients (13 male, 26 female, mean age 64.08 +/- 13.5 years) who underwent surgery for skull base meningiomas using microscope-based AR and automatic patient registration using intraoperative computed tomography (iCT). Results: Most common were olfactory meningiomas (6), cavernous sinus (6) and clinoidal (6) meningiomas, meningiomas of the medial (5) and lateral (5) sphenoid wing and meningiomas of the sphenoidal plane (5), followed by suprasellar (4), falcine (1) and middle fossa (1) meningiomas. There were 26 patients (66.6%) who underwent gross total resection (GTR) of the meningioma. Automatic registration applying iCT resulted in high accuracy (target registration error, 0.82 +/- 0.37 mm). The effective radiation dose of the registration iCT scans was 0.58 +/- 1.05 mSv. AR facilitated orientation in the resection of skull base meningiomas with encasement of cerebral vessels and compression of the optic chiasm, as well as in reoperations, increasing surgeon comfort. No injuries to critical neurovascular structures occurred. Out of 35 patients who lived to follow-up, 33 could ambulate at their last presentation. Conclusion: A microscope-based AR facilitates surgical orientation for resection of skull base meningiomas. Registration accuracy is very high using automatic registration with intraoperative imaging.
引用
收藏
页数:17
相关论文
共 37 条
  • [21] Accuracy of cup placement and pelvic motion in total hip arthroplasty in the lateral decubitus position using a new computed tomography-based navigation system with augmented reality technology
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (05) : 2381 - 2389
  • [22] Comparison of Using Intraoperative Computed Tomography-Based 3-Dimensional Navigation and Fluoroscopy in Anterior Cervical Diskectomy and Fusion for Cervical Spondylosis
    Nie, Jeffrey Z.
    Weber, Matthew W.
    Revelt, Nicolas J.
    Nordmann, Nathan J.
    Watson, Victoria L.
    Nie, James W.
    Menezes, Stephanie A.
    Delfino, Kristin
    Cozzens, Jeffrey W.
    Espinosa, Jose A.
    Amin, Devin
    Acakpo-Satchivi, Leslie
    WORLD NEUROSURGERY, 2022, 161 : E740 - E747
  • [23] Computed tomography-based virtual reality-guided preoperative simulation for endoscopic full-thickness resection of a gastric submucosal tumor
    Uozumi, Takeshi
    Abe, Seiichiro
    Sugimoto, Maki
    Kusuhara, Mitsunori
    Mizuguchi, Yasuhiko
    Nonaka, Satoru
    Saito, Yutaka
    ENDOSCOPY, 2024, 56 : E1010 - E1011
  • [24] Keyhole resection of intra-articular osteoid osteoma in the ulnar trochlear notch using 3-dimensional computed tomography-based navigation
    Ohta, Souichi
    Ikeguchi, Ryosuke
    Yurie, Hirofumi
    Takeuchi, Hisataka
    Mitsuzawa, Sadaki
    Matsuda, Shuichi
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (02) : E57 - E61
  • [25] Augmented reality navigation system for endoscopic surgery based on three-dimensional ultrasound and computed tomography: Application to 20 clinical cases
    Konishi, K
    Hashizume, M
    Nakamoto, M
    Kakeji, Y
    Yoshino, I
    Taketomi, A
    Sato, Y
    Tamura, S
    Maehara, Y
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 537 - 542
  • [26] Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography-Based Navigation With Automated Referencing, Part I: Cervicothoracic Spine
    Scheufler, Kai-Michael
    Franke, Joerg
    Eckardt, Anke
    Dohmen, Hildegard
    NEUROSURGERY, 2011, 69 (04) : 782 - 795
  • [27] Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography-Based Navigation With Automated Referencing. Part II: Thoracolumbar Spine
    Scheufler, Kai-Michael
    Franke, Joerg
    Eckardt, Anke
    Dohmen, Hildegard
    NEUROSURGERY, 2011, 69 (06) : 1307 - 1316
  • [28] Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography-Based Navigation With Automated Referencing, Part I: Cervicothoracic Spine COMMENTS
    Welch, William C.
    Heary, Robert F.
    NEUROSURGERY, 2011, 69 (04) : 795 - 795
  • [29] Ten-Step Biportal Endoscopic Transforaminal Lumbar Interbody Fusion Under Computed Tomography-Based Intraoperative Navigation: Technical Report and Preliminary Outcomes in Mexico
    Quillo-Olvera, Javier
    Quillo-Resendiz, Javier
    Quillo-Olvera, Diego
    Barrera-Arreola, Michelle
    Kim, Jin-Sung
    OPERATIVE NEUROSURGERY, 2020, 19 (05) : 608 - 618
  • [30] Comparison of Cup Setting Angle Accuracy between Computed Tomography-Based and Computed Tomography-Free Navigation in the Same Patients with Crowe's Classification I or II Hip Dysplasia
    Kaku, Nobuhiro
    Tagomori, Hiroaki
    Tsumura, Hiroshi
    CLINICS IN ORTHOPEDIC SURGERY, 2021, 13 (02) : 144 - 151