Flame AAS determination of total chromium in mussel samples using a continuous ultrasound-assisted extraction system connected to an on-line flow injection manifold
被引:0
|
作者:
Yebra, MC
论文数: 0引用数: 0
h-index: 0
机构:
Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, SpainUniv Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, Spain
Yebra, MC
[1
]
Moreno-Cid, A
论文数: 0引用数: 0
h-index: 0
机构:
Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, SpainUniv Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, Spain
Moreno-Cid, A
[1
]
Cespón, RM
论文数: 0引用数: 0
h-index: 0
机构:
Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, SpainUniv Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, Spain
Cespón, RM
[1
]
Cancela, S
论文数: 0引用数: 0
h-index: 0
机构:
Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, SpainUniv Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, Spain
Cancela, S
[1
]
机构:
[1] Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, Spain
Total chromium was extracted on-line from solid mussel samples using a simple, rapid, and continuous ultrasound-assisted extraction system (CUES). CUES is connected to a flow injection manifold, which permits the on-line flame atomic absorption spectrometric determination of chromium. The manifold for total chromium determination is the simplest possible because a volume of 83 muL of acid leachate was injected into a water carrier stream. An experimental design was used for optimization of the continuous leaching procedure: Compared to off-line ultrasonic-assisted extraction methods, the sonication time was reduced by a factor of 4-28. The method allowed a total sampling frequency of 11 samples per hour, with a relative standard deviation for the complete procedure of 1.7% [for a sample containing 2.9 mug/g chromium (wet mass)]. Accuracy was verified using TORT-1 certified reference material and the procedure applied to the analysis of mussel samples.
机构:
Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, SpainUniv Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, Spain
Yebra-Biurrun, Maria C.
Cancela-Perez, Sheila
论文数: 0引用数: 0
h-index: 0
机构:
Univ Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, SpainUniv Santiago de Compostela, Fac Chem, Dept Analyt Chem Nutr & Bromatol, Santiago De Compostela 15782, Spain