The development of an occupancy-controlled exhaust air ventilation system

被引:0
|
作者
Levin, P
机构
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Many dwellings with natural or gravity ventilation systems suffer from poor airchange rates. In Sweden, especially houses built in the 1960-ies and 1970-ies heated with electric resistance heating and thus without chimneys, are at risk. Improving the airchange rate in these houses is to some extent performed to decrease Radon gas concentrations where appropriate. For comfort, most homeowners learn to live with low airchange rates, accepting e.g. odours or window condensation and trying to compensate this with increased airing. They are often reluctant to install mechanical ventilation systems. This paper describes a new concept for an occupancy-controlled exhaust air ventilation system. The system features bedroom night-time ventilation, wet-room day-time ventilation and variable total air flow at a low installation cost. The system has since autumn 1994 been successfully installed in four houses and evaluated by air flow measurements, tracer gas tests, multizone airchange calculations etc. The homeowners are very pleased with the performance of the systems and the improved airchange rates.
引用
收藏
页码:539 / 547
页数:9
相关论文
共 50 条
  • [31] Status of catalyst development - Stationary scrubbing of exhaust air and exhaust gas
    Ohlrogge, U
    Schelchshorn, J
    ADVANCES IN CLEAR AIR TECHNOLOGY: OPTIMIZATION OF PRODUCTION-INTEGRATED ENVIRONMENTAL PROTECTION AND EXHAUST GAS PURIFICATION, 1999, 1478 : 163 - 178
  • [32] VENTILATION AND AIR-POLLUTION CONTROL .4. EXHAUST FANS
    NILL, RJ
    PETERSEN, T
    MABBETT, AN
    METAL FINISHING, 1985, 83 (03) : 63 - 65
  • [33] Local ventilation for powder handling - Combination of local supply and exhaust air
    Heinonen, K
    Kulmala, I
    Saamanen, A
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1996, 57 (04): : 356 - 364
  • [34] Mobility at the Development of Exhaust System
    Galindo, Mauricio Monteagudo
    SAE INTERNATIONAL JOURNAL OF PASSENGER CARS-MECHANICAL SYSTEMS, 2011, 4 (02): : 983 - 988
  • [35] Indoor airborne bacterial communities are influenced by ventilation, occupancy, and outdoor air source
    Meadow, J. F.
    Altrichter, A. E.
    Kembel, S. W.
    Kline, J.
    Mhuireach, G.
    Moriyama, M.
    Northcutt, D.
    O'Connor, T. K.
    Womack, A. M.
    Brown, G. Z.
    Green, J. L.
    Bohannan, B. J. M.
    INDOOR AIR, 2014, 24 (01) : 41 - 48
  • [36] EXPERIMENTAL ANALYSIS OF FUZZY CONTROLLED ENERGY EFFICIENT DEMAND CONTROLLED VENTILATION ECONOMIZER CYCLE VARIABLE AIR VOLUME AIR CONDITIONING SYSTEM
    Rajagopalan, Parameshwaran
    Rajasekaran, Karunakaran
    Alagarsamy, Senthilkumar
    Iniyan, S.
    Mohal, Lal D.
    THERMAL SCIENCE, 2008, 12 (03): : 15 - 32
  • [37] Microbial colonies in air of operating room under a well-controlled ventilation system
    Chen, Yin Yin
    Chen, Chii Shya
    Chen, Ian Horng
    HsinWu, Hui
    Wang, Fu Der
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2017, 50 : S251 - S252
  • [38] Occupancy Controlled Lighting System for Smart Buildings
    Atayero, Aderemi A.
    Ademu-Eteh, Victor
    Popoola, Segun I.
    Takpor, Temitope O.
    Badejo, Joke A.
    WORLD CONGRESS ON ENGINEERING AND COMPUTER SCIENCE, WCECS 2017, VOL II, 2017, : 707 - 710
  • [39] SYSTEM FOR REMOVAL OF TRITIUM FROM EXHAUST AIR
    HEERTJE, I
    GEHENIAU, MR
    KOCH, GK
    JOURNAL OF LABELLED COMPOUNDS, 1972, 8 (01): : 95 - &
  • [40] Long-duct forced and short-duct exhaust ventilation system in tunnels: Formation and dust control analysis of pressure ventilation air curtain
    Liu, Qiang
    Nie, Wen
    Hua, Yun
    Peng, Huitian
    Ma, He
    Yin, Shuai
    Guo, Lidian
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2019, 132 : 367 - 377