On measuring glucose concentration in solutions using radio frequency microwave

被引:0
|
作者
Kim, TW
Cho, TK
Park, BS
机构
[1] Hanyang Cyber Univ, Dept Informat & Commun, Seoul 133791, South Korea
[2] Sangmyung Univ, Dept Informat & Telecommun, Chungnamdo 330702, South Korea
[3] Sangmyung Univ, Dept Comp Syst Engn, Chungnamdo 330702, South Korea
关键词
measuring glucose concentration; radio frequency microwave; relative permittivity;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Radio frequency (RF) microwave can be used to predict glucose concentration in a sample. This paper presents preliminary results in determining the concentration by measuring relative permittivity in the solutions of distilled water, saline, human serum, and human blood containing glucose. In the experiments, sensitivity for detecting glucose concentration in blood solutions was almost 57 mg/dl at the frequency of approximately 5.8 GHz.
引用
收藏
页码:2905 / 2908
页数:4
相关论文
共 50 条
  • [31] Electrospun Nanofiber Biosensor for Measuring Glucose Concentration
    Shin, Young Jae
    Wang, Miao
    Kameoka, Jun
    JOURNAL OF PHOTOPOLYMER SCIENCE AND TECHNOLOGY, 2009, 22 (02) : 235 - 237
  • [32] Microwave Glucose Concentration Classification by Machine Learning
    Hossain, Md Shakhawat
    Iqbal, Samir M.
    Zhou, Yong
    PROCEEDINGS OF THE 2020 IEEE TEXAS SYMPOSIUM ON WIRELESS AND MICROWAVE CIRCUITS AND SYSTEMS (WMCS), 2020,
  • [33] MEASURING METHOD FOR COLLISION FREQUENCY BY A RADIO-FREQUENCY PROBE
    URAMOTO, J
    PHYSICS OF FLUIDS, 1970, 13 (03) : 657 - &
  • [35] MICROWAVE AND RADIO-FREQUENCY EXPOSURE LIMITS
    HARLEN, F
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1981, 128 (09): : 589 - 592
  • [36] MICROWAVE AND RADIO-FREQUENCY SPECTRUM OF XEHCL
    CHANCE, KV
    BOWEN, KH
    WINN, JS
    KLEMPERER, W
    JOURNAL OF CHEMICAL PHYSICS, 1979, 70 (11): : 5157 - 5160
  • [37] Radio frequency and microwave heating: a perspective for the millennium
    Metaxas, R
    POWER ENGINEERING JOURNAL, 2000, 14 (02): : 51 - 60
  • [38] A New Method for Online Measurement of Glucose Concentration Based on Laser Ranging and Radio Frequency Identification (RFID)
    Yu, Y. S.
    Ji, R. D.
    Wang, X. Y.
    Zhang, H. Y.
    Jiang, Q. S.
    Chen, R. C.
    Jiang, M. X.
    LASERS IN ENGINEERING, 2019, 44 (1-3) : 67 - 80
  • [39] Dielectric Properties of Aqueous Glucose Solutions Using Microwave Cavity and Coaxial Probe
    Choi, Heungjae
    Luzio, Steve
    Porch, Adrian
    2016 IEEE 2ND AUSTRALIAN MICROWAVE SYMPOSIUM (AMS), 2016, : 7 - 8
  • [40] Glucose solution concentration detection using TE011 microwave resonant cavity
    Li, Qiao
    Xiao, Xia
    Fu, Hao
    Wang, Liang
    JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 2018, 32 (14) : 1824 - 1833