Biomechanical evaluation of different fixation methods for tibial eminence fractures

被引:80
|
作者
Eggers, Anne Kathleen [1 ]
Becker, Christoph [1 ]
Weimann, Andre [1 ]
Herbort, Mirco [1 ]
Zantop, Thore [1 ]
Raschke, Michael J. [1 ]
Petersen, Wolf [1 ]
机构
[1] Univ Munster, Dept Trauma Hand & Reconstruct Surg, D-48149 Munster, Germany
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2007年 / 35卷 / 03期
关键词
anterior cruciate ligament; knee; fracture; biomechanics;
D O I
10.1177/0363546506294677
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Tibial eminence fractures have become more common, but the best method of fixing these fractures arthroscopically has not been elucidated. Objective: The objective of this study is to assess the stability of different fixation methods for tibial eminence fractures. Study Design: Controlled laboratory study. Methods: The authors evaluated the initial fixation strength of 4 different fixation techniques for tibial eminence fractures (2 screws, 1 screw, suture fixation with 1 mm Ethibond, and suture fixation with No. 5 FiberWire) using single cycle and cyclic loading tests. The tests were performed by loading the knee with an anterior tibial shear force. Results: Suture cerclage with the FiberWire showed significantly higher maximum load (599.6 N) and stiffness (36.99 N/mm) than all other fixation methods tested. The lowest maximum load in the single cycle loading test was observed in the group with 2 screws (1 screw, 371.2 N; 2 screws, 249.8 N). The lowest stiffness was found in the Ethibond group (14.5 N/mm). After 1000 cycles of loading, the maximum load of the FiberWire fixation was significantly higher than the maximum load of the Ethibond fixation (399.4 N), the fixation with 1 screw (354.2 N), and the fixation with 2 screws (301.5 N). Conclusion: These biomechanical data suggest that under cyclic loading conditions, suture fixation of tibial eminence fractures provides more fixation strength than screw fixation. Clinical Relevance: A second screw has no positive effect on the biomechanical characteristics of screw fixation.
引用
收藏
页码:404 / 410
页数:7
相关论文
共 50 条
  • [41] Arthroscopic treatment of displaced tibial eminence fractures using a suspensory fixation
    Loriaut, Philippe
    Moreau, Pierre-Emmanuel
    Loriaut, Patrick
    Boyer, Patrick
    INDIAN JOURNAL OF ORTHOPAEDICS, 2017, 51 (02) : 187 - 191
  • [42] Pediatric and adolescent tibial eminence fractures: Arthroscopic cannulated screw fixation
    Reynders, P
    Reynders, K
    Broos, P
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 53 (01): : 49 - 54
  • [43] Arthroscopic Reduction and Internal Fixation of Tibial Eminence Fractures With Transosseous Suture Bridge Fixation
    Wolfson, Theodore
    Vadhera, Amar S.
    Parvaresh, Kevin
    Verma, Nikhil
    LaPrade, Robert F.
    Chahla, Jorge
    ARTHROSCOPY TECHNIQUES, 2021, 10 (04): : E1039 - E1046
  • [44] A simple modified arthroscopic procedure for fixation of displaced tibial eminence fractures
    Osti, L
    Merlo, F
    Liu, SH
    Bocchi, L
    ARTHROSCOPY, 2000, 16 (04): : 379 - 382
  • [45] Technique for arthroscopic suture fixation of displaced tibial intercondylar eminence fractures
    Kogan, MG
    Marks, P
    Amendola, A
    ARTHROSCOPY, 1997, 13 (03): : 301 - 306
  • [46] A biomechanical comparison of four different fixation methods for midshaft clavicle fractures
    Chen, Yang
    Yang, Yang
    Ma, Xinlong
    Xu, Weiguo
    Ma, Jianxiong
    Zhu, Shaowen
    Ma, Baoyi
    Xing, Dan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (01) : 13 - 19
  • [47] COMMINUTED FRACTURES OF THE POSTERIOR WALL OF THE ACETABULUM - A BIOMECHANICAL EVALUATION OF FIXATION METHODS
    GOULET, JA
    ROULEAU, JP
    MASON, DJ
    GOLDSTEIN, SA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (10): : 1457 - 1463
  • [48] Biomechanical Evaluation of Four Methods for Internal Fixation of Comminuted Subtrochanteric Fractures
    Wang, Jie
    Ma, Jian-xiong
    Jia, Hao-bo
    Chen, Yang
    Yang, Yang
    Ma, Xin-long
    MEDICINE, 2016, 95 (19)
  • [49] Biomechanical comparison of different fixation methods on the tibial side in anterior cruciate ligament reconstruction: a biomechanical study in porcine tibial bone
    Tetsumura, S
    Fujita, A
    Nakajima, M
    Abe, M
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2006, 11 (03) : 278 - 282
  • [50] Tibial eminence fractures in children
    Wall, EJ