Fast neutron spectra measurement in a copper using a 252Cf standard neutron source

被引:8
|
作者
Schulc, Martin [1 ]
Kostal, Michal [1 ]
Matej, Zdenek [2 ]
Czakoj, Tomas [1 ]
Novak, Evzen [1 ]
机构
[1] Res Ctr Rez Ltd, Husinec Rez 25068 130, Czech Republic
[2] Masaryk Univ, Fac Informat, Bot 68a, Brno 60200, Czech Republic
关键词
Copper cross sections; (252) Cf; Fast neutron leakage spectrum; D-T NEUTRONS; BENCHMARK EXPERIMENT; NUCLEAR-DATA; VERIFICATION;
D O I
10.1016/j.radphyschem.2021.109871
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The presented paper focuses on the measurement of fast neutron leakage spectra in the copper assembly using an intense standard Cf-252(sf) source. The neutron spectra were measured by a stilbene organic scintillation detector and compared with MCNP6.2 calculations using copper nuclear data from the ENDF/B-VIII.0, ENDF/B-VII.1, JEFF-3.3, JEFF-3.2, JENDL-4.0 and CENDL-3.1 libraries in the energy range of 1-10 MeV. Discrepancies appear in the intermediate neutron energy range between experiment and calculation. The best agreement with an experiment was achieved using ENDF/B-VIII.0 library in the region of 1-4.5 MeV. In the region of 4.5-10 MeV, the best agreement was achieved using JENDL-4.0 or CENDL-3.1 library. The largest discrepancies in the whole energy range were found for calculations involving JEFF-3.3 copper evaluations.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Analytic representation of the fission neutron spectra of 235U and 252Cf
    Koshelev, AS
    Sevast'yanov, VD
    ATOMIC ENERGY, 2000, 88 (04) : 310 - 313
  • [42] Shielding design studies for a neutron irradiator system based on a 252Cf source
    da Silva, AX
    Crispim, VR
    RADIATION PROTECTION DOSIMETRY, 2001, 95 (04) : 333 - 338
  • [43] Instrumental neutron activation analysis of Al, V and Ti employing 252Cf as a thermal neutron source
    Narkhede, S. S.
    Turel, Z. R.
    Journal of Radioanalytical and Nuclear Chemistry, 200 (05):
  • [44] Characteristics of the simulated workplace neutron fields using a 252Cf source surrounded with cylindrical moderators
    Tsujimura, N
    Yoshida, T
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 117 - 121
  • [45] New evidence of an intense scission neutron source in the 252Cf spontaneous fission
    Kornilov, NV
    Kagalenko, AB
    Poupko, SV
    Androsenko, PA
    Hambsch, FJ
    NUCLEAR PHYSICS A, 2001, 686 : 187 - 203
  • [46] Determining 252Cf source strength by absolute passive neutron correlation counting
    Croft, S.
    Henzlova, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 714 : 5 - 12
  • [47] Measurement of prompt fission neutron spectrum for spontaneous fission of 252Cf using γ multiplicity tagging
    Blain, E.
    Daskalakis, A.
    Block, R. C.
    Danon, Y.
    PHYSICAL REVIEW C, 2017, 95 (06)
  • [48] Proton beam dosimetry using a TEPC with a 252Cf neutron calibration
    Nam, Uk-Won
    Park, Won-Kee
    Lee, Jaejin
    Pyo, Jeonghyun
    Moon, Bongkon
    Kim, Sunghwan
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (08) : 1459 - 1462
  • [49] Design, Construction, and Modeling of a 252Cf Neutron Irradiator
    Anderson, Blake C.
    Holbert, Keith E.
    Bowler, Herbert
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2016, 2016
  • [50] Measurement of dose enhancement by neutron capture of boron in 252Cf interstitial brachytherapy
    Abd El-Hafez, AI
    Eissa, HM
    Eman, SA
    Fadel, MA
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 441 - 444