Enhanced Sensitivity for the Determination of Lithium by Miniaturized Liquid Cathode Glow Discharge (LCGD) Atomic Emission Spectrometry (AES) with the Addition of Surfactants

被引:2
|
作者
Lu, Quanfang [1 ,2 ]
Feng, Yan [1 ]
Luo, Hui [1 ]
Yu, Jie [1 ]
Kang, Yuejing [1 ]
机构
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Lanzhou 730070, Peoples R China
[2] Northwest Normal Univ, Editorial Dept Univ Journal, Lanzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Atomic emission spectrometry; cetyltrimethylammonium bromide; liquid cathode glow discharge; lithium determination; surfactant; DIELECTRIC-BARRIER DISCHARGE; TRACE HEAVY-METALS; ATMOSPHERIC-PRESSURE; ANALYTICAL PERFORMANCE; ELEMENTAL ANALYSIS; NONIONIC SURFACTANTS; EXCITATION SOURCE; FORMIC-ACID; CONTACT; WATER;
D O I
10.1080/00032719.2022.2072856
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniature atomic emission spectrometry (AES) was developed using a liquid cathode glow discharge (LCGD) as an excitation source and optical fiber spectrometer as the detection system. The instrument was employed for the sensitive determination of lithium (Li). The addition of 0.15% cetyltrimethylammonium chloride (CTAC), 0.15% cetyltrimethylammonium bromide (CTAB) and 3 critical micelle concentration (CMC) Triton X-405 enhanced the Li emission by 3.7-, 3.2-, and 1.8-fold, respectively. The presence of 50 mg L-1 Al3+ and SO42- inhibited the recovery of 0.5 mg L-1 Li about 73% and 75%, respectively. After adding CTAB, CTAC, and Triton X-405, the recovery of Li was from 98% to 108%, suggesting that the addition of surfactant eliminated the Al3+ and SO42- interferences. The sensitivity of Li was improved by adding the surfactants by factors of 2.3 for 0.15% CTAB, 2.0 for 0.15% CTAC, and 1.9 for 3 CMC Triton X-405. The limit of detection (LOD) with 0.15% CTAB for Li was 0.55 mu g L-1 which was improved by 5.6-fold. In addition, the energy consumption was below 60 W and good precision was obtained. The accuracy, reliability, and repeatability of the proposed method were verified by analysis of water samples and satisfactory recoveries between 91% and 115% were obtained. The results demonstrate that LCGD-AES with surfactants can be used for highly sensitive determination of Li in complex samples because of its low cost, small size, and low power consumption.
引用
收藏
页码:2789 / 2802
页数:14
相关论文
共 50 条
  • [21] Determination of silicate by hollow cathode glow discharge-atomic emission spectrometry with hydride generation technique
    Fujiwara, K
    Wagner, EP
    Smith, BW
    Winefordner, JD
    ANALYTICAL LETTERS, 1996, 29 (11) : 1985 - 1992
  • [22] Application of Solution Cathode Glow Discharge-Atomic Emission Spectrometry for the Rapid Determination of Calcium in Milk
    Hao Jun
    Wang Yu
    Liu Cong
    Wu Zan
    Shao Peng
    Zu Wen-chuan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (12) : 3797 - 3801
  • [23] Sensitivity improvement of solution cathode glow discharge-atomic emission spectrometry by using refrigerating anodes for optical determination of metal elements
    Zheng, Peichao
    Luo, Yuanjiang
    Wang, Jinmei
    Hu, Qiang
    Yang, Yang
    Mao, Xuefeng
    Lai, Chunhong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (06) : 1228 - 1234
  • [24] Flow Injection Photochemical Vapor Generation Coupled with Miniaturized Solution-Cathode Glow Discharge Atomic Emission Spectrometry for Determination and Speciation Analysis of Mercury
    Mo, Jiamei
    Li, Qing
    Guo, Xiaohong
    Zhang, Guoxia
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2017, 89 (19) : 10353 - 10360
  • [25] Determination of gold in precious alloys by glow discharge atomic emission spectrometry
    Senofonte, O
    Caroli, S
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (07) : 869 - 872
  • [26] Determination of gold in precious alloys by glow discharge atomic emission spectrometry
    Senofonte, Oreste, 1600, Royal Soc of Chemistry, Cambridge, United Kingdom (15):
  • [27] Determination of thallium at trace levels by electrolyte cathode discharge atomic emission spectrometry with improved sensitivity
    Shekhar, R.
    Madhavi, K.
    Meeravali, N. N.
    Kumar, Sunil Jai
    ANALYTICAL METHODS, 2014, 6 (03) : 732 - 740
  • [28] Determination of trace elements in steels by gas-jet enhanced glow discharge atomic emission spectrometry
    Kim, HJ
    Park, YS
    Kim, JS
    Lee, JJ
    Kim, YH
    CANADIAN JOURNAL OF APPLIED SPECTROSCOPY, 1996, 41 (06): : 139 - 144
  • [29] DETERMINATION OF LITHIUM ION BY LIQUID-PHASE DIAPHRAGM GLOW DISCHARGE-ATOMIC EMISSION SPECTROSCOPY
    Liu, Yongjun
    Sun, Bing
    Wang, Lei
    ANALYTICAL LETTERS, 2014, 47 (08) : 1409 - 1420
  • [30] Optimization of hollow cathode diameter for particle beam/hollow cathode glow discharge atomic emission spectrometry
    Dempster, MA
    Marcus, RK
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (06) : 599 - 610