An Efficient Algorithm Based on Spectrum Migration for High Frame Rate Ultrasound Imaging

被引:2
|
作者
Feng, Shuai [1 ]
Jin, Liu [1 ]
Wang, Yadan [1 ]
Zhao, Wei [1 ,2 ]
Peng, Hu [1 ]
Qiao, Heyuan [1 ]
机构
[1] Hefei Univ Technol, Dept Biomed Engn, Hefei 230009, Peoples R China
[2] Yijishan Hosp, Wannan Med Coll, Wuhu 241001, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
High frame rate imaging; spectrum migration; Fourier migration; DIFFRACTION; SYSTEM; FIELDS;
D O I
10.32604/cmes.2021.014027
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The high frame rate (HFR) imaging technique requires only one emission event for imaging. Therefore, it can achieve ultrafast imaging with frame rates up to the kHz regime, which satisfies the frame rate requirements for imaging moving tissues in scientific research and clinics. Lu's Fourier migration method is based on a non diffraction beam to obtain HFR images and can improve computational speed and efficiency. However, in order to obtain high-quality images, Fourier migration needs to make full use of the spectrum of echo signals for imaging, which requires a large number of Fast Fourier Transform (FFT) points and increases the complexity of the hardware when the echo frequency is high. Here, an efficient algorithm using the spectrum migration technique based on the spectrum's distribution characteristics is proposed to improve the imaging efficiency in HFR imaging. Since the actual echo signal spectrum is of limited bandwidth, low-frequency and high-frequency parts with low-energy have little contribution to the imaging spectrum. We transform the effective part that provides the main energy in the signal spectrum to the imaging spectrum while the ineffective spectrum components are not utilized for imaging. This can significantly reduce the number of Fourier transform points, improve Fourier imaging efficiency, and ensure the imaging quality. The proposed method is evaluated on simulated and experimental datasets. Results demonstrated that the proposed method could achieve equivalent image quality with a reduced point number for FFT compared to the complete spectrum migration. In this paper, it only requires a quarter of the FFT points used in the complete spectrum migration, which can improve the computational efficiency; thus, it is more suitable for real-time data processing. The proposed spectrum migration method has a specific significance for the study and clinical application of HFR imaging.
引用
收藏
页码:739 / 754
页数:16
相关论文
共 50 条
  • [1] Elasticity Imaging using High Frame Rate Ultrasound Imaging
    Park, Suhyun
    Aglyamov, Salavat R.
    Scott, W. Guy
    Emelianov, Stanislav Y.
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 602 - +
  • [2] High Frame Rate Ultrasound Displacement Vector Imaging
    Kruizinga, Pieter
    Mastik, Frits
    Bosch, Johannes G.
    de Jong, Nico
    van Soest, Gijs
    van der Steen, Antonius F. W.
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 707 - 709
  • [3] High frame rate ultrasonic imaging system based on the angular spectrum principle
    Peng, Hu
    Lu, Jianyu
    Han, XueMei
    [J]. ULTRASONICS, 2006, 44 : E97 - E99
  • [4] An improved spread-spectrum method for high-frame-rate color Doppler ultrasound imaging
    Mansour, Omar
    Poepping, Tamie L.
    Lacefield, James C.
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [5] Very High Frame Rate Ultrasound for Medical Diagnostic Imaging
    Hasegawa, Hideyuki
    [J]. ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING: FROM THEORY TO APPLICATIONS, SERIES 2, 2019, 2173
  • [6] A Prototype System for High Frame Rate Ultrasound Imaging based Prosthetic Arm Control
    Singh, Ayush
    Gopalkrishnan, Pisharody Harikrishnan
    Panicker, Mahesh Raveendranatha
    [J]. 2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [7] High Frame Rate Super Resolution Imaging Based on Ultrasound Synthetic Aperture Scheme
    Wada, Takayuki
    Ho, Yihsin
    Okubo, Kan
    Tagawa, Norio
    Hirose, Yoshiyasu
    [J]. PROCEEDINGS OF THE 2015 ICU INTERNATIONAL CONGRESS ON ULTRASONICS, 2015, 70 : 1216 - 1220
  • [8] Resolution, Sidelobe, and Contrast Analysis of Ultrasound Fourier Based High Frame Rate Imaging
    Wang, Zhaohui
    [J]. 2020 IEEE INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND INFORMATION TECHNOLOGY (ISSPIT 2020), 2020,
  • [9] Apodizing Delay and Auto-Correlation Reconstruction Algorithm for High-Frame-Rate Ultrasound Imaging
    Li, Chunqi
    Clegg, Harry R.
    Carpenter, Thomas M.
    Nie, Luzhen
    Freear, Steven
    Cowell, David M. J.
    McLaughlan, James R.
    [J]. PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [10] Compressed Sensing for High Frame Rate, High Resolution and High Contrast Ultrasound Imaging
    Liu, Jing
    He, Qiong
    Luo, Jianwen
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 1552 - 1555