High frame rate ultrasonic imaging system based on the angular spectrum principle

被引:9
|
作者
Peng, Hu [1 ]
Lu, Jianyu
Han, XueMei
机构
[1] Univ Sci & Technol China, Dept Elect Sci & Technol, Hefei 230026, Peoples R China
[2] Univ Toledo, Dept Bioengn, Ultrasound Lab, Toledo, OH 43606 USA
基金
中国国家自然科学基金;
关键词
high frame rate; array beam; Fourier transform; angular spectrum;
D O I
10.1016/j.ultras.2006.06.024
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A kind of high frame rate ( HFR) 2D and 3D imaging method was developed by Jianyu Lu in 1997. Because only one transmission is required to construct a frame of image, this method can reach an ultra high frame rate ( about 3750 volumes or frames per second for biological soft tissues at a depth of 200 mm). In this paper, a new HFR method is presented in the view of angular spectrum. Compared with conventional dynamic focusing method which uses delay- and- sum processing, and Lu's HFR method which uses a kind of special weighting on the received signal, the new method only uses the Fourier transform algorithm to construct image. So the system implementation of the method could be greatly simplified. During constructing image, several array beams with different parameter are used as transmitted signal, and the spectrum of a frame of image is obtained by synthesizing the image spectrums related to different transmit event. The simulation result shows that the solution not only suppresses the sidelobe of system greatly and obtains the high quality image, but also still keeps high frame rate to some extent. (c) 2006 Elsevier B. V. All rights reserved.
引用
收藏
页码:E97 / E99
页数:3
相关论文
共 50 条
  • [1] A new model of ultrasonic imaging system based on plane wave transmission and angular spectrum propagation principle
    Peng, Hu
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON INTEGRATION TECHNOLOGY, PROCEEDINGS, 2007, : 307 - 310
  • [2] Development of a high frame rate ultrasonic system for cardiac imaging in small animals
    Sun, Lei
    Cannata, Jonathan M.
    Johnson, Jeffrey A.
    Yen, Jesse T.
    Feng, Ching
    Shung, K. Kirk
    [J]. MEDICAL IMAGING 2006: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2006, 6147
  • [3] Study on the transmission system of high frame rate ultrasonic imaging based on the non-diffraction wave
    Wei Yong-Mei
    Peng Hu
    [J]. ACTA PHYSICA SINICA, 2014, 63 (19)
  • [4] High frame rate ultrasonic Imaging system based-on linear frequency-modulated signal
    Han Xuemei
    Peng Hu
    Du Hongwei
    Feng Huanqing
    [J]. 2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1712 - 1715
  • [5] A high-frame rate high-frequency ultrasonic system for cardiac imaging in mice
    Sun, Lei
    Richard, William D.
    Cannata, Jonathan M.
    Feng, Ching C.
    Johnson, Jeffrey A.
    Yen, Jesse T.
    Shung, K. Kirk
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (08) : 1648 - 1655
  • [6] Study on application of complementary Golay code into high frame rate ultrasonic imaging system
    Peng, Hu
    Han, XueMei
    Lu, Jianyu
    [J]. ULTRASONICS, 2006, 44 (SUPPL.) : E93 - E96
  • [7] An Efficient Algorithm Based on Spectrum Migration for High Frame Rate Ultrasound Imaging
    Feng, Shuai
    Jin, Liu
    Wang, Yadan
    Zhao, Wei
    Peng, Hu
    Qiao, Heyuan
    [J]. CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2021, 126 (02): : 739 - 754
  • [9] A STUDY OF HIGH FRAME RATE ULTRASONIC IMAGING WITH LIMITED DIFFRACTION BEAMS
    刘立庄
    卞正中
    姚斌
    [J]. Journal of Pharmaceutical Analysis, 2003, (01) : 107 - 110
  • [10] A real-time high frame rate high frequency ultrasonic system for cardiac imaging in small animals
    Sun, Lei
    Feng, Ching
    Cannata, Jonathan M.
    Johnson, Jeffrey A.
    Yen, Jesse T.
    Shung, K. Kirk
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2206 - +