Efficacy of mitomycin C irrigation after removal of an occluded nasolacrimal stent

被引:2
|
作者
Kim, Kyung Rae
Song, Ho-Young
Shin, Ji Hoon
Kim, Jin Hyoung
Choi, Eugene K.
Lee, Yong Jae
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol, Seoul 138736, South Korea
[3] Cornell Univ, Weill Med Coll, New York, NY USA
[4] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Ophthalmol, Seoul, South Korea
关键词
D O I
10.1016/j.jvir.2007.01.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Mitomycin C (MMC) acts as a potent fibroblastic inhibitor, and topical application of MMC is effective in preventing scar formation. The purpose of this study was to evaluate the safety and efficacy of MMC irrigation after removal of an occluded nasolacrimal stent from the lacrimal system. MATERIALS AND METHODS: A total of 57 lacrimal systems after removal of an occluded stent were assigned to one of two groups: 23 lacrimal systems were irrigated with MMC after stent removal (MMC group), and 34 lacrimal systems were not irrigated with MMC after stent removal (non-MMC group). In the MMC group, the lacrimal systems were irrigated with 0.2 mg/mL MMC through the inferior lacrimal punctum for 3 minutes in three different sessions: immediately, 1 week, and 1 month after stent removal. The mean and cumulative patency rates after stent removal were calculated using the Kaplan-Meier method and were compared between the two groups using the log-rank test. RESULTS: Stent removal and MMC irrigation were technically successful in all lacrimal systems. There were no side effects or complications associated with MMC use. The mean patency rate after stent removal was higher in the MMC group than that of the non-MMC group: 10.5 months (95% CI: 7.04, 13.91) versus 4.5 months (95% CI: 2.40, 6.63), respectively. There was a statistically significant difference in the cumulative patency rates after stent removal between the two groups (P = .005, log-rank test). CONCLUSIONS: Mitomycin C irrigation is safe and effective in increasing patency rate of lacrimal systems after removal of an occluded nasolacrimal stent.
引用
收藏
页码:519 / 525
页数:7
相关论文
共 50 条
  • [31] PALATAL STENT AFTER TORUS REMOVAL
    DAVIS, WM
    BUCHS, AU
    JOURNAL OF ORAL SURGERY, 1979, 37 (09): : 680 - 681
  • [32] Feasibility and safety of airway bypass stent placement and influence of topical mitomycin C on stent patency
    Choong, CK
    Haddad, FJ
    Gee, EY
    Cooper, JD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (03): : 632 - 638
  • [33] Emergent Carotid Stent Removal after Carotid Stent Thrombosis
    Moulakakis, Konstantinos G.
    Lazaris, Andreas M.
    ANNALS OF VASCULAR SURGERY, 2018, 46 : 401 - 406
  • [34] A case of mitomycin C toxicity after XEN gel stent implantation with the XEN air technique in a glaucoma patient
    Baeg, Joon Young
    Choi, Han Sol
    Lee, Si Hyung
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [35] A case of mitomycin C toxicity after XEN gel stent implantation with the XEN air technique in a glaucoma patient
    Joon Young Baeg
    Han Sol Choi
    Si Hyung Lee
    BMC Ophthalmology, 23
  • [36] Efficacy of mitomycin C in reducing recurrence of anterior urethral stricture after internal optical urethrotomy
    Ali, Liaqat
    Shahzad, Muhammad
    Orakzai, Nasir
    Khan, Ihsanullah
    Ahmad, Mubashira
    KOREAN JOURNAL OF UROLOGY, 2015, 56 (09) : 650 - 655
  • [37] Mitomycin C as an alternative to stent for conservative management of esophageal strictures in children
    Uhlen, S
    Fayoux, P
    Michaud, L
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2005, 40 (02): : 235 - 236
  • [38] Efficacy of angioscopy in determining the effectiveness of intracoronary urokinase and TEC atherectomy thrombus removal from an occluded saphenous vein graft prior to stent implantation
    Kaplan, BM
    Safian, RD
    Goldstein, JA
    Grines, CL
    ONeill, WW
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1995, 36 (04): : 335 - 337
  • [39] Spontaneous displacement of polyurethane nasolacrimal duct stent into the throat 4 years after insertion
    Ghazi-Nouri, S
    Thompson, G
    EYE, 2001, 15 (5) : 684 - 684
  • [40] PROPHYLAXIS OF NASOLACRIMAL DUCT OBSTRUCTION AFTER MAJOR SINUS SURGERY USING A SILICONE STENT
    FISHER, EW
    CLARKE, PM
    CHEESMAN, AD