Retinal image analysis to detect and quantify lesions associated with diabetic retinopathy

被引:0
|
作者
Sánchez, CI [1 ]
Hornero, R [1 ]
López, MI [1 ]
Poza, J [1 ]
机构
[1] Univ Valladolid, Dept Teor Senal & Comun, ETSI Telecomun, Valladolid, Spain
关键词
diabetic retinopathy; hard exudates; image processing; retinal images;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
An automatic method to detect hard exudates, a lesion associated with diabetic retinopathy, is proposed. The algorithm found on their color, using a statistical classification, and their sharp edges, applying an edge detector, to localize them. A sensitivity of 79.62% with a mean number of 3 false positives per image is obtained in a database of 20 retinal image with variable color, brightness and quality. In that way, we evaluate the robustness of the method in order to make adequate to a clinical environment. Further efforts will be done to improve its performance.
引用
收藏
页码:1624 / 1627
页数:4
相关论文
共 50 条
  • [21] MultiColor imaging to detect different subtypes of retinal microaneurysms in diabetic retinopathy
    Arrigo, Alessandro
    Teussink, Michel
    Aragona, Emanuela
    Bandello, Francesco
    Battaglia Parodi, Maurizio
    [J]. EYE, 2021, 35 (01) : 277 - 281
  • [22] MultiColor imaging to detect different subtypes of retinal microaneurysms in diabetic retinopathy
    Alessandro Arrigo
    Michel Teussink
    Emanuela Aragona
    Francesco Bandello
    Maurizio Battaglia Parodi
    [J]. Eye, 2021, 35 : 277 - 281
  • [23] Retinal thickness analysis (RTA) - An objective method to assess and quantify the retinal thickness in healthy controls and in diabetics without diabetic retinopathy
    Fritsche, P
    van der Heijde, R
    Suttorp-Schulten, MAS
    Polak, BC
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2002, 22 (06): : 768 - 771
  • [24] Improved automated digital retinal image analysis for detection of diabetic retinopathy through image quality restoration
    Soliz, P
    Raman, B
    Nemeth, S
    Barriga, S
    Zamora, G
    Bursell, E
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [25] Facilitating diabetic retinopathy screening using automated retinal image analysis in underresourced settings
    Quinn, Nicola
    Brazionis, Laima
    Zhu, Benjamin
    Ryan, Chris
    D'Aloisio, Rossella
    Lilian Tang, Hongying
    Peto, Tunde
    Jenkins, Alicia
    [J]. DIABETIC MEDICINE, 2021, 38 (09)
  • [26] Retinal sensitivity changes associated with diabetic neuropathy in the absence of diabetic retinopathy
    Neriyanuri, Srividya
    Pardhan, Shahina
    Gella, Laxmi
    Pal, Sakshyar Saumya
    Ganesan, Suganeswari
    Sharma, Tarun
    Raman, Rajiv
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (09) : 1174 - 1178
  • [27] A Universal Retinal Image Template for Automated Screening of Diabetic Retinopathy
    V. V. Starovoitov
    Yu. I. Golub
    M. M. Lukashevich
    [J]. Pattern Recognition and Image Analysis, 2022, 32 : 322 - 331
  • [28] A Universal Retinal Image Template for Automated Screening of Diabetic Retinopathy
    Starovoitov, V. V.
    Golub, Yu. I.
    Lukashevich, M. M.
    [J]. PATTERN RECOGNITION AND IMAGE ANALYSIS, 2022, 32 (02) : 322 - 331
  • [29] Retinal image quality assessment for diabetic retinopathy screening: A survey
    Lin, Jiawen
    Yu, Lun
    Weng, Qian
    Zheng, Xianghan
    [J]. MULTIMEDIA TOOLS AND APPLICATIONS, 2020, 79 (23-24) : 16173 - 16199
  • [30] Diabetic Retinopathy Retinal Image Enhancement Based on Gamma Correction
    Xiao, Zhitao
    Zhang, Xinpeng
    Zhang, Fang
    Geng, Lei
    Wu, Jun
    Su, Long
    Chen, Liming
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (01) : 149 - 154