Changes in Cortical Oxyhaemoglobin Signal During Low-Intensity Cycle Ergometer Activity: A Near-Infrared Spectroscopy Study

被引:9
|
作者
Tsubaki, Atsuhiro [1 ]
Takai, Haruna [1 ]
Kojima, Sho [1 ]
Miyaguchi, Shota [1 ]
Sugawara, Kazuhiro [1 ]
Sato, Daisuke [1 ]
Tamaki, Hiroyuki [1 ]
Onishi, Hideaki [1 ]
机构
[1] Niigata Univ Hlth & Welf, Inst Human Movement & Med Sci, Kita Ku, 1398 Shimami Cho, Niigata 9503198, Japan
来源
基金
日本学术振兴会;
关键词
Cortical oxyhaemoglobin; Skin blood flow; Mean arterial pressure; Low-intensity exercise; Near-infrared spectroscopy; SKIN BLOOD-FLOW; CEREBRAL OXYGENATION; CORTEX; ACTIVATION; EXERCISE; HUMANS; MOTOR; TASK; STIMULATION; TOPOGRAPHY;
D O I
10.1007/978-1-4939-3023-4_10
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Near-infrared spectroscopy (NIRS) is a widely used non-invasive method for measuring human brain activation based on the cerebral hemodynamic response during gross motor tasks. However, systemic changes can influence measured NIRS signals. We aimed to determine and compare time-dependent changes in NIRS signal, skin blood flow (SBF), and mean arterial pressure (MAP) during low-intensity, constant, dynamic exercise. Nine healthy volunteers (22.1 +/- 1.7 years, 3 women) participated in this study. After a 4-min pre-exercise rest and a 4-min warm-up, they exercised on a bicycle ergometer at workloads corresponding to 30 % VO2 peak for 20 min. An 8-min rest period followed the exercise. Cortical oxyhaemoglobin signals (O(2)Hb) were recorded while subjects performed the exercise, using an NIRS system. Changes in SBF and MAP were also measured during exercise. O(2)Hb increased to 0.019 mM cm over 6 min of exercise, decreased slightly from 13 min towards the end of the exercise. SBF continued to increase over 16 min of the exercise period and thereafter decreased till the end of measurement. MAP fluctuated from -1.0 to 7.1 mmHg during the exercise. Pearson's correlation coefficients between SBF and O(2)Hb, and MAP and O(2)Hb differed in each time phase, from -0.365 to 0.713. During low-intensity, constant, dynamic exercise, the profile of changes in measurements of O(2)Hb, SBF, and MAP differed. These results suggested that it is necessary to confirm the relationship between O(2)Hb and systemic factors during motor tasks in order to detect cortical activation during gross motor tasks.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 50 条
  • [31] A Functional Near-Infrared Spectroscopy Study on the Cortical Haemodynamic Responses During the Maastricht Acute Stress Test
    N. K. Schaal
    P. Hepp
    A. Schweda
    O. T. Wolf
    C. Krampe
    Scientific Reports, 9
  • [32] Functional Near-Infrared Spectroscopy to Probe tDCS -Induced Cortical Functioning Changes in Tinnitus
    Verma, Rohit
    Jha, Amit
    Singh, Shuchita
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2019, 15 (02): : 321 - 325
  • [33] A Functional Near-Infrared Spectroscopy Study on the Cortical Haemodynamic Responses During the Maastricht Acute Stress Test
    Schaal, N. K.
    Heppe, P.
    Schweda, A.
    Wolf, O. T.
    Krampe, C.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [34] Changes in tissue oxyhaemoglobin concentration measured using multichannel near infrared spectroscopy during internal carotid angiography
    Germon, TJ
    Evans, PE
    Barnett, NJ
    Lewis, TT
    Wall, P
    Nelson, RJ
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1997, 63 (05): : 660 - 664
  • [35] AN OBSERVATIONAL STUDY OF NEAR-INFRARED SPECTROSCOPY DURING CAROTID ENDARTERECTOMY
    KIRKPATRICK, PJ
    SMIELEWSKI, P
    WHITFIELD, PC
    CZOSNYKA, M
    MENON, D
    PICKARD, JD
    JOURNAL OF NEUROSURGERY, 1995, 82 (05) : 756 - 763
  • [36] Cortical Hemodynamic Response Associated with Spatial Coding: A Near-Infrared Spectroscopy Study
    Abiot Y. Derbie
    Bolton Chau
    Bess Lam
    Yun-hua Fang
    Kin-Hung Ting
    Clive Y. H. Wong
    Jing Tao
    Li-dian Chen
    Chetwyn C. H. Chan
    Brain Topography, 2021, 34 : 207 - 220
  • [37] Cortical Hemodynamic Response Associated with Spatial Coding: A Near-Infrared Spectroscopy Study
    Derbie, Abiot Y.
    Chau, Bolton
    Lam, Bess
    Fang, Yun-hua
    Ting, Kin-Hung
    Wong, Clive Y. H.
    Tao, Jing
    Chen, Li-dian
    Chan, Chetwyn C. H.
    BRAIN TOPOGRAPHY, 2021, 34 (02) : 207 - 220
  • [38] Simultaneous measurement of neuronal activity and cortical hemodynamics by unshielded magnetoencephalography and near-infrared spectroscopy
    Seki, Yusuke
    Miyashita, Tsuyoshi
    Kandori, Akihiko
    Maki, Atsushi
    Koizumi, Hideaki
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (10)
  • [39] Prediction for finger force from cortical activity measured by near-infrared spectroscopy (NIRS)
    Nambu, Isao
    Osu, Rieko
    Ando, Soichi
    Naito, Eiichi
    Kawato, Mitsuo
    NEUROSCIENCE RESEARCH, 2007, 58 : S128 - S128
  • [40] Cerebral hemodynamic changes during limb-shaking TIA: A near-infrared spectroscopy study
    Kassab, Ali
    Tremblay, Julie
    Poppe, Alexandre Y.
    Letourneau-Guillon, Laurent
    Gallagher, Anne
    Dang Khoa Nguyen
    NEUROLOGY, 2016, 86 (12) : 1166 - 1168