A comparison of ultrasound-guided and palpation-guided identification of lumbar puncture needle entry site in patients as body mass index increases

被引:0
|
作者
Joseph, Linda [1 ]
Mehrotra, Mayank [2 ]
Jeanmonod, Rebecca [3 ]
Jeanmonod, Donald [3 ]
机构
[1] Methodist Charlton Med Ctr, Dept Emergency Med, Dallas, TX USA
[2] Augusta Univ, Dept Anesthesia, Med Coll Georgia, Augusta, GA USA
[3] St Lukes Univ Hosp, Dept Emergency Med, Bethlehem, PA USA
关键词
Body mass index; lumbar puncture; obesity; ultrasound;
D O I
10.4103/IJAM.IJAM_45_18
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This was a prospective, crossover study examining the ability of emergency medicine (EM) residents to identify lumbar puncture (LP) needle entry site by palpation and ultrasound in individuals with varying body mass indexes (BMIs). Materials and Methods: Following a didactic session on the use of ultrasound to identify landmarks for LP needle entry, EM resident physicians were asked to identify LP needle entry sites using ultrasound on several volunteers of varying BMIs (normal [BMI, 18.5-24.9], overweight [BMI, 25.0-29.9], and obese [BMI, 30-39.9]). Measurements of their deviation from an entry point determined by a faculty member with expertise in ultrasound were recorded. Residents were then asked to determine LP needle entry sites using palpation and again the deviation was recorded. Results: Using ultrasound, the transverse and longitudinal deviations from a gold standard were 7.8 mm (standard deviation [SD]: 6.5 and confidence interval [CI]: 1.9) and 7.1 mm (SD: 5.2 and CI: 1.5), respectively, whereas using palpation, the transverse and longitudinal deviations from our gold standard were 4.4 mm (SD: 3.4 and CI: 0.99) and 8.2 mm (SD: 6.6 and CI: 1.9), respectively. Conclusion: There was no difference in the residents' ability to identify LP needle entry sites on volunteers of various BMIs when comparing the use of ultrasound to standard palpation. The following core competencies are addressed in this article: Patient care and procedural skills, Medical knowledge.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 50 条
  • [31] Cost-effectiveness comparison between palpation- and ultrasound-guided thyroid fine-needle aspiration biopsies
    Ahmet Selçuk Can
    BMC Endocrine Disorders, 9
  • [32] Ultrasound-guided explantation technique for implantable loop recorder in patients with high body mass index: a practical approach
    Thaitirarot, Chokanan
    Sze, Shirley
    Armstrong, Suzanne
    Somani, Riyaz
    HEART RHYTHM O2, 2024, 5 (03): : 198 - 199
  • [33] Ultrasound-guided percutaneous nephrolithotomy (PCNL) success rates in patients with elevated body mass index: a comparative study
    Dolev Perez
    Binyamin B. Neeman
    David Dotan
    Galiya Raisin
    Boris Chertin
    Ilan Kafka
    Urolithiasis, 51
  • [34] Ultrasound-guided percutaneous nephrolithotomy (PCNL) success rates in patients with elevated body mass index: a comparative study
    Perez, Dolev
    Neeman, Binyamin B.
    Dotan, David
    Raisin, Galiya
    Chertin, Boris
    Kafka, Ilan
    UROLITHIASIS, 2023, 51 (01)
  • [35] ULTRASOUND-GUIDED PERCUTANEOUS NEPHROLITHOTOMY (PCNL) SUCCESS RATES IN PATIENTS WITH ELEVATED BODY MASS INDEX, A COMPARATIVE STUDY
    Perez, Dolev
    Dotan, David
    Neeman, Binyamin
    Chertin, Boris
    Kafka, Ilan
    JOURNAL OF UROLOGY, 2023, 209 : E306 - E307
  • [36] Fluoroscopic-Guided Lumbar Puncture: Fluoroscopic Time and Implications of Body Mass Index-A Baseline Study
    Boddu, S. R.
    Corey, A.
    Peterson, R.
    Saindane, A. M.
    Hudgins, P. A.
    Chen, Z.
    Wang, X.
    Applegate, K. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (08) : 1475 - 1480
  • [37] Body mass index is related to unsuccessful puncture attempts and failure to axillary vein cannulation during ultrasound-guided cardiac electronic device implantation
    De Sensi, Francesco
    Addonisio, Luigi
    Baratta, Pasquale
    Breschi, Marco
    Cresti, Alberto
    Miracapillo, Gennaro
    Limbruno, Ugo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 61 (02) : 253 - 259
  • [38] Body mass index is related to unsuccessful puncture attempts and failure to axillary vein cannulation during ultrasound-guided cardiac electronic device implantation
    Francesco De Sensi
    Luigi Addonisio
    Pasquale Baratta
    Marco Breschi
    Alberto Cresti
    Gennaro Miracapillo
    Ugo Limbruno
    Journal of Interventional Cardiac Electrophysiology, 2021, 61 : 253 - 259
  • [39] Ultrasound-guided lumbar puncture with a needle-guidance system: A prospective and controlled study to evaluate the learnability and feasibility of a newly developed approach
    Backhaus, Tilo
    von Cranach, Moritz
    Brich, Jochen
    PLOS ONE, 2018, 13 (04):
  • [40] Palpation, ultrasound, and ultrasound-guided fine-needle aspiration cytology in the assessment of cervical lymph node status in head and neck cancer patients
    Atula, TS
    Grenman, R
    Varpula, MJ
    Kurki, TJI
    Klemi, PJ
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 1996, 18 (06): : 545 - 551