Physiology of Intraluminal Administration of Carbon Dioxide as a Contrast Medium

被引:0
|
作者
Patelis, Nikolaos [1 ]
Doulaptsis, Mikes [2 ]
Kykalos, Stylianos [3 ]
Spartalis, Eleftherios [4 ]
Maskanakis, Anastasios [5 ]
Georgopoulos, Sotirios [6 ]
机构
[1] Athens Med Ctr, Maroussi, Greece
[2] Gen Hosp Georgios Gennimatas, Dept Vasc Surg, Athens, Greece
[3] Univ Athens, Laiko Gen Hosp, Dept Propaedeut Surg 2, Athens Greece, Athens, Greece
[4] Univ Athens, Lab Expt Surg & Surg Res, Athens, Greece
[5] Univ Thessaly, Univ Hosp Larissa, Vasc Surg Dept, Larisa, Greece
[6] Univ Athens, Laiko Gen Hosp, Dept Surg 1, Vasc Unit, Athens, Greece
关键词
CO2; carbon dioxide; angiography; medical imaging; venography; digital subtraction angiography; English literature; DIGITAL-SUBTRACTION-ANGIOGRAPHY; CO2; ANGIOGRAPHY; AIR CONTAMINATION; SYSTEM; GAS; VISUALIZATION; NEPHROPATHY; SAFE;
D O I
10.2174/1381612825666191209124911
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Carbon dioxide (CO2) exists in nature around us. In the middle of the 20th century, the intraluminal injection of CO2 demonstrated similar results to those of Digital Subtraction Angiography (DSA) with an iodinated contrast agent (ICA). Since then, the technology behind CO2 DSA has developed significantly. Objective: The aim of this study is to inform physicians about the unique properties of CO2 and its physiology after intraluminal injection. Methods: An extensive search for English literature on the properties of CO2 and the physiology of intraluminal administration was conducted using Pubmed. Results: There is sufficient literature on the properties of CO2 and the physiology of CO2 DSA. A review of this literature explains what happens to the human organism after the injection of CO2. Conclusion: There is enough evidence that CO2 DSA is both effective, diagnostic and safe, but the properties of CO2 should be taken under consideration as complications occur, although rarely.
引用
收藏
页码:4656 / 4661
页数:6
相关论文
共 50 条
  • [41] Administration of contrast medium in spiral CT: Results of a consensus conference
    Feuerbach, S
    Lorenz, W
    Klose, KJ
    Gmeinwieser, J
    Lackner, KJ
    Landwehr, P
    Grabbe, E
    Kloppel, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1996, 164 (02): : 158 - 165
  • [42] Shock following administration of contrast medium in a patient with Kawasaki disease
    Toru Watanabe
    Pediatric Radiology, 2010, 40 : 1304 - 1305
  • [43] Shock following administration of contrast medium in a patient with Kawasaki disease
    Watanabe, Toru
    PEDIATRIC RADIOLOGY, 2010, 40 (07) : 1304 - 1305
  • [44] Nonconvulsive status epilepticus after intravenous contrast medium administration
    Lukovits, TG
    Fadul, CE
    Pipas, JM
    Williamson, PD
    EPILEPSIA, 1996, 37 (11) : 1117 - 1120
  • [45] RECTAL TRAUMA BY CONTRAST MEDIUM ADMINISTRATION WITH SEVERE PERMANENT RESULTS
    BAHLS, G
    CHIRURG, 1970, 41 (11): : 522 - &
  • [46] Iodide mumps after intravenous and oral administration of contrast medium
    Linn, JF
    Fichtner, J
    Duber, C
    Hohenfellner, R
    JOURNAL OF UROLOGY, 1996, 156 (05): : 1774 - 1774
  • [47] INTRAVENOUS CARBON-DIOXIDE AS AN ECHOCARDIOGRAPHIC CONTRAST AGENT
    MELTZER, RS
    SERRUYS, PW
    HUGENHOLTZ, PG
    ROELANDT, J
    CIRCULATION, 1980, 62 (04) : 20 - 20
  • [48] INTRAVENOUS CARBON-DIOXIDE AS AN ECHOCARDIOGRAPHIC CONTRAST AGENT
    MELTZER, RS
    SERRUYS, PW
    HUGENHOLTZ, PG
    ROELANDT, J
    JOURNAL OF CLINICAL ULTRASOUND, 1981, 9 (03) : 127 - 131
  • [49] DOUBLE CONTRAST BARIUM CYSTOGRAPHY UTILIZING CARBON DIOXIDE
    POCHACZEVSKY, R
    GRABSTALD, H
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1964, 92 (02): : 365 - &
  • [50] CARBON-DIOXIDE GAS AS AN ARTERIAL CONTRAST AGENT
    SEEGER, JM
    SELF, S
    HARWARD, TRS
    FLYNN, TC
    HAWKINS, IF
    ANNALS OF SURGERY, 1993, 217 (06) : 688 - 698