Microanalytical study of sub-nanoliter samples by capillary electrophoresis - mass spectrometry with 100 % injection efficiency

被引:6
|
作者
Mark, Jonas Josef Peter [1 ]
Beutner, Andrea [1 ]
Cindric, Marija [1 ]
Matysik, Frank-Michael [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
关键词
Capillary electrophoresis; Mass spectrometry; Injection efficiency; Small samples; Cyclic nucleotides; Sample preconcentration; SINGLE-DROP MICROEXTRACTION; BATCH INJECTION; HUMAN URINE; SEPARATION; DRUGS; PHASE;
D O I
10.1007/s00604-014-1339-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is presented for conducting fast capillary electrophoresis (CE) with ultrasmall sample volumes (< 10 nL) and subsequent determination of target analytes by time-of-flight mass spectrometry (TOF-MS). Furthermore, an approach towards preconcentration by solvent evaporation of samples as small as 500 nL is shown. Ultrasmall samples of biologically important cyclic nucleotides (cyclic guanosine monophosphate, cyclic adenosine monophosphate, cyclic cytidine monophosphate) served as model compounds. Sample volumes as small as 500 pL were used to perform sample uptake and CE injections by capillary batch injection (CBI). This resulted in detection limits between 2 and 5 fmol. The fast rate of sample evaporation prevents the operation of nano-/subnano-liter samples under room temperature conditions. A CBI-CE-TOF-MS setup incorporating a Peltier element and a thermostat was used for the handling of very small samples. In combination with tapered fused silica injection capillaries and the high-precision guiding system of the CBI setup, nearly 100 % efficient injections of ultrasmall samples into funnelled separation capillaries could be managed. The overall system allowed for high-throughput CE separations from densely arranged sample droplets or vials with RSD of peak heights ranging from 6 to 8 % (n = 5). CE-TOF-MS separations of mixtures of cyclic nucleotides were carried out in capillaries as short as 20 cm (25 mu m ID) in less than 55 s with high separation efficiency. We report details of the setup and optimizations with respect to etching of capillaries (tapering and funnelling), sample uptake and injection as well as separation of the model compounds. Moreover, the capabilities of the experimental setup for preconcentration of target analytes by solvent evaporation are described. Preconcentration factors of up to 100 could be achieved. This approach was successfully used for the determination of the cyclic nucleotide cGMP in (spiked) human urine samples.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [21] Analysis of naphthenic acids in produced water samples by capillary electrophoresis-mass spectrometry
    Pinheiro, Kemilly M. P.
    Sako, Alysson V. F.
    Rodrigues, Marcella F.
    Vaz, Boniek G.
    Medeiros Junior, Iris
    Carvalho, Rogerio M.
    Coltro, Wendell K. T.
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (19)
  • [22] Enhancing Proteomic Throughput in Capillary Electrophoresis-Mass Spectrometry by Sequential Sample Injection
    Faserl, Klaus
    Sarg, Bettina
    Sola, Laura
    Lindner, Herbert H.
    PROTEOMICS, 2017, 17 (22)
  • [23] Study of the kynurenine pathway of tryptophan metabolism by capillary electrophoresis and mass spectrometry
    A. A. Sidorova
    L. A. Kartsova
    Journal of Analytical Chemistry, 2011, 66 : 322 - 326
  • [24] Study of the kynurenine pathway of tryptophan metabolism by capillary electrophoresis and mass spectrometry
    Sidorova, A. A.
    Kartsova, L. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (03) : 322 - 326
  • [25] Evaluation of on-line solid-phase extraction capillary electrophoresis - mass spectrometry with a nanoliter valve for the analysis of peptide biomarkers
    Pero-Gascon, Roger
    Benavente, Fernando
    Neusuess, Christian
    Sanz-Nebot, Victoria
    ANALYTICA CHIMICA ACTA, 2020, 1140 (1140) : 1 - 9
  • [26] Analysis of lysozyme in cheese samples by on-line combination of capillary zone electrophoresis and mass spectrometry
    Kondekova, Monika
    Maier, Vitezslav
    Ginterova, Pavlina
    Marak, Jozef
    Sevcik, Juraj
    FOOD CHEMISTRY, 2014, 153 : 398 - 404
  • [27] Using capillary electrophoresis-selective tandem mass spectrometry to identify pathogens in clinical samples
    Hu, Anren
    Chen, Cheng-Tung
    Tsai, Pei-Jen
    Ho, Yen-Peng
    ANALYTICAL CHEMISTRY, 2006, 78 (14) : 5124 - 5133
  • [28] Capillary electrophoresis tandem mass spectrometry to determine multiclass cyanotoxins in reservoir water and spinach samples
    Carmona-Molero, Rocio
    Aparicio-Muriana, M. Mar
    Lara, Francisco J.
    Garcia-Campan, Ana M.
    del Olmo-Iruela, Monsalud
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1717
  • [29] Alternatives for coupling sequential injection systems to commercial capillary electrophoresis-mass spectrometry equipment
    Santos, B.
    Simonet, B. M.
    Lendl, B.
    Rios, A.
    Valcarcel, M.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) : 278 - 285
  • [30] Development of a miniaturized injection cell for online electrochemistry-capillary electrophoresis-mass spectrometry
    Herl, Thomas
    Heigl, Nicole
    Matysik, Frank-Michael
    MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1685 - 1691