Assessment of tricuspid valve by two- and three-dimensional echocardiography with special reference to percutaneous repair and prosthetic valve implantation procedures

被引:4
|
作者
Murray, Christopher S. G. [1 ]
Salama, Ahmed Y. [2 ]
Akdogan, Raziye E. [2 ]
Harb, Serge [3 ]
Nahar, Tamanna [4 ]
Nanda, Navin C. [2 ]
机构
[1] Columbia Univ, Dept Internal Med, Harlem Hosp Ctr, New York, NY USA
[2] Univ Alabama Birmingham, Dept Med, Div Cardiovasc Dis, Birmingham, AL 35294 USA
[3] Cleveland Clin, Inst Heart & Vasc, Dept Cardiovasc Med, Sect Cardiovasc Imaging, Cleveland, OH 44106 USA
[4] Columbia Univ, Dept Internal Med, Harlem Hosp Ctr, Sect Cardiol, New York, NY USA
关键词
echocardiography; three-dimensional echocardiography; transcatheter tricuspid valve repair; transcatheter tricuspid valve-in-valve; tricuspid regurgitation; tricuspid valve; two-dimensional echocardiography; EUROPEAN ASSOCIATION; REGURGITATION LATE; INCREMENTAL VALUE; AMERICAN SOCIETY; MITRACLIP SYSTEM; REAL-TIME; FOLLOW-UP; SURGERY; MANAGEMENT; ADULTS;
D O I
10.1111/echo.14130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Moderate-to-severe tricuspid regurgitation affects approximately 1.6 million people in the United States. An estimated 8000 patients will undergo tricuspid surgery annually, leaving a large number of patients with this condition untreated. Many of these individuals who are not referred for surgery engender a large unmet clinical need; this may be primarily due to the surgical risk involved. In persons who are categorized as high-risk surgical candidates, percutaneous procedures present a viable alternative. The majority of developmental attention as regards percutaneous approaches has been focused on the aortic and mitral valves recently, but few data are available about the feasibility and efficacy of minimally invasive tricuspid valve treatment. We review the usefulness of two- and three-dimensional echocardiography in the assessment of the tricuspid valve with special reference to recent interest in percutaneous repair and prosthetic valve implantation procedures for severe functional tricuspid regurgitation.
引用
下载
收藏
页码:1419 / 1438
页数:20
相关论文
共 50 条
  • [21] Incremental Value of the En Face View of the Tricuspid Valve by Two-Dimensional and Three-Dimensional Echocardiography for Accurate Identification of Tricuspid Valve Leaflets
    Stankovic, Ivan
    Daraban, Ana Maria
    Jasaityte, Ruta
    Neskovic, Aleksandar N.
    Claus, Piet
    Voigt, Jens-Uwe
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (04) : 376 - 384
  • [22] Nonplanarity of the tricuspid valve annulus: Assessment by real-time three-dimensional echocardiography
    Ton-Nu, TT
    Levine, RA
    Handschumaker, MD
    Fan, DL
    Jiang, L
    Hung, J
    CIRCULATION, 2004, 110 (17) : 655 - 656
  • [23] Acute changes in mitral valve geometry after percutaneous valve repair with MitraClip XTR by three-dimensional echocardiography
    Tusa, Maurizio B.
    Barletta, Marta
    Rubbio, Antonio Popolo
    Travaglio, Nicole
    Saffioti, Silvia
    Granata, Giuseppina
    Mantovani, Valentina
    Stefanini, Elisa
    Corciu, Anca, I
    Testa, Luca
    Bedogni, Francesco
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2021, 38 (11): : 1913 - 1923
  • [24] Three-dimensional versus two-dimensional transesophageal echocardiography in mitral valve repair
    Garcia-Orta, Rocio
    Moreno, Eduardo
    Vidal, Matilde
    Ruiz-Lopez, Fuensanta
    Oyonarte, Jose M.
    Lara, Juan
    Moreno, Teodoro
    Garcia-Fernandezd, Miguel A.
    Azpitarte, Jose
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (01) : 4 - 12
  • [25] Two- and Three-Dimensional Transesophageal Echocardiography for Aortic Valve Aneurysms on the Right Coronary Cusp
    Kuroda, Masataka
    Takemae, Akihito
    Takahashi, Toshikazu
    Mita, Norikatsu
    Kagaya, Shin
    Miyoshi, Sohtaro
    Kadoi, Yuji
    Saito, Shigeru
    ANESTHESIA AND ANALGESIA, 2013, 116 (04): : 784 - 787
  • [26] Double-orifice mitral valve assessed by two- and three-dimensional echocardiography in a newborn
    Seguela, Pierre-Emmanuel
    Dulac, Yves
    Acar, Phillipe
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2011, 104 (05) : 361 - 362
  • [27] Two- and three-dimensional echocardiography in primary antiphospholipid syndrome:: misdiagnosis as rheumatic valve disease
    Espinola-Zavaleta, N
    Amigo, MC
    Vargas-Barrón, J
    Keirns, C
    Cárdenas, AR
    Vidal, M
    Roldán, J
    LUPUS, 2001, 10 (07) : 511 - 513
  • [28] Prenatal diagnosis of fetal absent pulmonary valve syndrome by two- and three-dimensional echocardiography
    Lei, Wenjia
    Sun, Xue
    Siddiqui, Faiza Amber
    Wang, Yu
    Zhang, Ying
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (07): : 1063 - 1065
  • [29] Unusual bileaflet tricuspid valve by real time three-dimensional echocardiography
    Anwar, Ashraf M.
    Attia, Wael M.
    Nosir, Youssef F. M.
    El-Amin, Ali M.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (05): : 534 - 536
  • [30] Carcinoid tricuspid valve disease: incremental value of three-dimensional echocardiography
    Muraru, Denisa
    Tuveri, Maria Francesca
    Marra, Martina Perazzolo
    Badano, Luigi Paolo
    Iliceto, Sabino
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (04) : 329 - 329