A comprehensive uncertainty evaluation of double-sensor conductivity probe

被引:4
|
作者
Wang, Dewei [1 ]
Fu, Yucheng [1 ]
Liu, Yang [1 ]
Talley, Justin D. [2 ]
Worosz, Ted [2 ]
Hogan, Kevin [2 ]
Buchanan, John R., Jr. [2 ]
机构
[1] Virginia Tech, Dept Mech Engn, Nucl Engn Program, Blacksburg, VA 24061 USA
[2] Naval Nucl Lab, West Mifflin, PA 15122 USA
关键词
Two-phase flow; Double-sensor conductivity probe; Bubbles; Measurement uncertainty; INTERFACIAL AREA CONCENTRATION; NUMERICAL EVALUATION; 2-PHASE; BENCHMARKING;
D O I
10.1016/j.pnucene.2021.103741
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The double-sensor conductivity probe is one widely used technique for measuring local time-averaged parameters in two-phase flows. Although a number of studies have been carried out in the past, a good understanding of the uncertainty of this technique is still lacking. This paper aims to address this gap by performing a systematic and comprehensive study on the measurement uncertainty of the probe. Three types of uncertainties are analyzed: that of measurands, of the model input parameters, and of the mathematical models. A Monte Carlo uncertainty evaluation framework simulating the measuring process is developed to link various uncertainty sources to the time-averaged two-phase flow quantities output by the probe. Various sensitivity studies on model uncertainties, model input uncertainties and their propagations are performed. The uncertainties in primitive time measurement are studied by specially designed tests. Results show that there are random errors and systematic delays in the interfacial time measured by the probe. These errors are correlated by bubble velocity, DAQ frequency and signal processing threshold. The analysis shows that a large uncertainty could exist in the velocity measurement for high-velocity-low-frequency conditions. The errors in primitive length measurements are quantified by both experiments and analysis. It shows that the flow-induced deflection and vibration are unnoticeable in the test section for a superficial liquid velocity up to 4 m/s. Another test is performed using a high speed camera to study the flow disturbance caused by a double-sensor probe. Test results show that the probe has minimal disturbance to the upstream region of the measuring location, though bubbles have been diverted by the probe downstream.
引用
下载
收藏
页数:17
相关论文
共 50 条
  • [1] Numerical evaluation of the uncertainty of double-sensor conductivity probe for bubbly flow measurement
    Wang, D.
    Liu, Y.
    Talley, J. D.
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2018, 107 : 51 - 66
  • [2] Double-sensor conductivity probe applied in a flotation system
    Aires, Pedro Silva
    Afacan, Artin
    Liu, Qi
    Prasad, Vinay
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2023, 101 (11): : 6100 - 6113
  • [3] Measurement of CBM Bubble Parameters by Double-Sensor Conductivity Probe
    Xuming Zhu
    Yuliang Zou
    Xiaoming Wu
    Ziwei Jiang
    Chemistry and Technology of Fuels and Oils, 2021, 56 : 1020 - 1027
  • [4] Measurement of CBM Bubble Parameters by Double-Sensor Conductivity Probe
    Zhu, Xuming
    Zou, Yuliang
    Wu, Xiaoming
    Jiang, Ziwei
    CHEMISTRY AND TECHNOLOGY OF FUELS AND OILS, 2021, 56 (06) : 1020 - 1027
  • [5] Local measurement of bubbly flow in helically coiled tubes using double-sensor conductivity probe
    Huang, Yichuan
    Gui, Nan
    Yang, Xingtuan
    Tu, Jiyuan
    Jiang, Shengyao
    Zhu, Hongye
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2020, 57 (06) : 689 - 703
  • [6] Sensitivity study on double-sensor conductivity probe for the measurement of interfacial area concentration in bubbly flow
    Wu, Q
    Ishii, M
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1999, 25 (01) : 155 - 173
  • [7] Numerical simulation of double-sensor conductivity probe measurement mechanism for two-phase flow
    Liu H.
    Pan L.
    Deng J.
    Yuan D.
    Huang Y.
    1600, Atomic Energy Press (37): : 180 - 184
  • [8] Measurement of local two-phase flow parameters of nanofluids using conductivity double-sensor probe
    Yu Sun Park
    Soon Heung Chang
    Nanoscale Research Letters, 6
  • [9] Measurement of gas entrainment from stationary liquid slug in horizontal tube with double-sensor conductivity probe
    Wang, Xin
    Wang, Tongji
    He, Limin
    FLOW MEASUREMENT AND INSTRUMENTATION, 2012, 27 : 81 - 91
  • [10] Measurement of local two-phase flow parameters of nanofluids using conductivity double-sensor probe
    Park, Yu Sun
    Chang, Soon Heung