The quadrant method measuring four points is as a reliable and accurate as the quadrant method in the evaluation after anatomical double-bundle ACL reconstruction

被引:11
|
作者
Mochizuki, Yuta [1 ]
Kaneko, Takao [1 ]
Kawahara, Keisuke [1 ]
Toyoda, Shinya [1 ]
Kono, Norihiko [1 ]
Hada, Masaru [1 ]
Ikegami, Hiroyasu [1 ]
Musha, Yoshiro [1 ]
机构
[1] Toho Univ, Sch Med, Dept Orthopaed Surg Ohashi, Meguro Ku, 2-17-6 Ohashi, Tokyo 1538515, Japan
关键词
Anterior cruciate ligament reconstruction; Quadrant method; 3-Dimensional computed tomography; Femoral tunnel position; ANTERIOR CRUCIATE LIGAMENT; 3-DIMENSIONAL COMPUTED-TOMOGRAPHY; FEMORAL TUNNEL POSITION; PLAIN RADIOGRAPHY; INSERTION SITES; KNEE; LOCATION; GRAFT; DISSECTION; KINEMATICS;
D O I
10.1007/s00167-017-4797-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The quadrant method was described by Bernard et al. and it has been widely used for postoperative evaluation of anterior cruciate ligament (ACL) reconstruction. The purpose of this research is to further develop the quadrant method measuring four points, which we named four-point quadrant method, and to compare with the quadrant method. Three-dimensional computed tomography (3D-CT) analyses were performed in 25 patients who underwent double-bundle ACL reconstruction using the outside-in technique. The four points in this study's quadrant method were defined as point1-highest, point2-deepest, point3-lowest, and point4-shallowest, in femoral tunnel position. Value of depth and height in each point was measured. Antero-medial (AM) tunnel is (depth1, height2) and postero-lateral (PL) tunnel is (depth3, height4) in this four-point quadrant method. The 3D-CT images were evaluated independently by 2 orthopaedic surgeons. A second measurement was performed by both observers after a 4-week interval. Intra- and inter-observer reliability was calculated by means of intra-class correlation coefficient (ICC). Also, the accuracy of the method was evaluated against the quadrant method. Intra-observer reliability was almost perfect for both AM and PL tunnel (ICC > 0.81). Inter-observer reliability of AM tunnel was substantial (ICC > 0.61) and that of PL tunnel was almost perfect (ICC > 0.81). The AM tunnel position was 0.13% deep, 0.58% high and PL tunnel position was 0.01% shallow, 0.13% low compared to quadrant method. The four-point quadrant method was found to have high intra- and inter-observer reliability and accuracy. This method can evaluate the tunnel position regardless of the shape and morphology of the bone tunnel aperture for use of comparison and can provide measurement that can be compared with various reconstruction methods. The four-point quadrant method of this study is considered to have clinical relevance in that it is a detailed and accurate tool for evaluating femoral tunnel position after ACL reconstruction. Case series, Level IV.
引用
收藏
页码:2389 / 2394
页数:6
相关论文
共 50 条
  • [31] The relationship between graft intensity on MRI and tibial tunnel placement in anatomical double-bundle ACL reconstruction
    Takanori Teraoka
    Yusuke Hashimoto
    Shinji Takahashi
    Shinya Yamasaki
    Yohei Nishida
    Hiroaki Nakamura
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 1749 - 1758
  • [32] The relationship between graft intensity on MRI and tibial tunnel placement in anatomical double-bundle ACL reconstruction
    Teraoka, Takanori
    Hashimoto, Yusuke
    Takahashi, Shinji
    Yamasaki, Shinya
    Nishida, Yohei
    Nakamura, Hiroaki
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (08): : 1749 - 1758
  • [33] Characteristics of the femoral tunnel of anatomical and isometric single bundle anterior cruciate ligament reconstruction: a modeling analysis based on quadrant method and anatomical landmarks
    Yin, Li
    Liao, Dongfa
    Xie, Qingyun
    Liu, Jinbiao
    Deng, Bing
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [34] App-based analysis of the femoral tunnel position in ACL reconstruction using the quadrant method
    Mueller, Maximilian M.
    Tenfelde, Oliver
    Hinz, Nico
    Pagenstert, Geert
    Frosch, Karl-Heinz
    Hoeher, Juergen
    Akoto, Ralph
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (07) : 3137 - 3144
  • [35] Strategies for revision surgery after primary double-bundle anterior cruciate ligament (ACL) reconstruction
    Hofbauer, Marcus
    Muller, Bart
    Murawski, Christopher D.
    Baraga, Michael
    van Eck, Carola Franziska
    Fu, Freddie H.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (09) : 2072 - 2080
  • [36] Anatomic Double-Bundle and Single-Bundle ACL Reconstruction After ACL Rupture Did Not Differ for Quality of Life at 2 Years
    Gobbi, Alberto
    Whyte, Graeme P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (10): : 943 - 943
  • [37] Validation of a new protocol for computer-assisted evaluation of kinematics of double-bundle ACL reconstruction
    Martelli, S
    Zaffagnini, S
    Bignozzi, S
    Bontempi, M
    Marcacci, M
    CLINICAL BIOMECHANICS, 2006, 21 (03) : 279 - 287
  • [38] Strategies for revision surgery after primary double-bundle anterior cruciate ligament (ACL) reconstruction
    Marcus Hofbauer
    Bart Muller
    Christopher D. Murawski
    Michael Baraga
    Carola Franziska van Eck
    Freddie H. Fu
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2072 - 2080
  • [39] Macroscopic and microscopic findings of multi-folded hamstring grafts of anatomical double-bundle ACL reconstruction 13 years after surgery
    Daiki Kumaki
    Keiji Tensho
    Mai Iwaya
    Tomoya Iwaasa
    Kazushige Yoshida
    Suguru Koyama
    Hiroki Shimodaira
    Hiroshi Horiuchi
    Jun Takahashi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 2406 - 2411
  • [40] Macroscopic and microscopic findings of multi-folded hamstring grafts of anatomical double-bundle ACL reconstruction 13 years after surgery
    Kumaki, Daiki
    Tensho, Keiji
    Iwaya, Mai
    Iwaasa, Tomoya
    Yoshida, Kazushige
    Koyama, Suguru
    Shimodaira, Hiroki
    Horiuchi, Hiroshi
    Takahashi, Jun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (06) : 2406 - 2411