Palliative Radiotherapy for Bleeding from Unresectable Gastric Cancer Using Three-Dimensional Conformal Technique

被引:5
|
作者
Kawabata, Hideaki [1 ]
Fujii, Takashi [2 ]
Yamamoto, Tetsuya [1 ]
Satake, Hiroaki [1 ]
Yamaguchi, Katsutoshi [1 ]
Okazaki, Yuji [1 ]
Nakase, Kojiro [1 ]
Miyata, Masatoshi [1 ]
Motoi, Shigehiro [1 ]
机构
[1] Kyoto Okamoto Mem Hosp, Dept Gastroenterol, Kyoto 6130034, Japan
[2] Kyoto Okamoto Mem Hosp, Dept Radiol, Kyoto 6130034, Japan
关键词
palliative radiotherapy; gastric cancer; bleeding; hemostasis; reirradiation; RADIATION-THERAPY;
D O I
10.3390/biomedicines10061394
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Optimal regimens using recent radiotherapy (RT) equipment for bleeding gastric cancer (GC) have not been fully investigated yet. We retrospectively reviewed the clinical data of 20 patients who received RT for bleeding GC in our institution between 2016 and 2021. Three-dimensional conformal RT was performed. The effectiveness of RT was evaluated by the mean serum hemoglobin (Hb) level and the number of transfused red blood cell (RBC) units 1 month before and after RT. The median first radiation dose was a BED of 39.9 Gy. The treatment success rate was 95% and the rebleeding rate was 10.5%. There was a significant increase in the mean Hb level (8.0 +/- 1.1 vs. 9.8 +/- 1.3 g/dL, p = 0.01), and a significant decrease in the mean number of transfused RBC units (6.8 +/- 3.3 vs. 0.6 +/- 1.5 units, p < 0.01). Severe toxicity was observed in two patients (anorexia [n = 1] and gastrointestinal [GI] perforation [n = 1]). Reirradiation was attempted in three patients (for hemostasis [n = 2] and for mass reduction [n = 1]). The retreatment success rate for rebleeding was 100%. GI perforation occurred in two patients who had received hemostatic reirradiation. Palliative RT for bleeding GC using recent technology had excellent efficacy. However, it may be associated with a risk of GI perforation.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Comparison of IMRT, three-dimensional conformal and combined planning techniques in lung cancer radiotherapy
    Kutuk, T.
    Pehlivanli, A.
    Hicsonmez, A.
    Gokce, S. Cakir
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S896 - S896
  • [42] Three dimensional conformal neutron radiotherapy for prostate cancer
    Paul J. Chuba
    Richard Maughan
    Jeffrey D. Forman
    Strahlentherapie und Onkologie, 1999, 175 : 79 - 81
  • [43] A comparison of dosimetric parameters between tomotherapy and three-dimensional conformal radiotherapy in rectal cancer
    Mina Yu
    Joo Hwan Lee
    Hong Seok Jang
    Dong Min Jeon
    Jae Suk Cheon
    Hyo Chun Lee
    Jong Hoon Lee
    Radiation Oncology, 8
  • [44] A comparison of dosimetric parameters between tomotherapy and three-dimensional conformal radiotherapy in rectal cancer
    Yu, Mina
    Lee, Joo Hwan
    Jang, Hong Seok
    Jeon, Dong Min
    Cheon, Jae Suk
    Lee, Hyo Chun
    Lee, Jong Hoon
    RADIATION ONCOLOGY, 2013, 8
  • [45] Potency preservation after three-dimensional conformal radiotherapy for prostate cancer - Preliminary results
    Wilder, RB
    Chou, RH
    Ryu, JK
    Stern, RL
    Wong, MS
    Ji, M
    Roach, M
    White, RD
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2000, 23 (04): : 330 - 333
  • [46] Isolated plexiform neurofibroma: Treatment with three-dimensional conformal radiotherapy
    Robertson, TC
    Buck, DA
    Schmidt-Ullrich, R
    Powers, CN
    Reiter, ER
    LARYNGOSCOPE, 2004, 114 (07): : 1139 - 1142
  • [47] Three-dimensional conformal brachytherapy for prostate cancer
    Zelefsky M.J.
    Current Urology Reports, 2004, 5 (3) : 173 - 178
  • [48] Conformal three-dimensional photon radiotherapy for paranasal sinus tumors
    Lohr, F
    Pirzkall, A
    Debus, J
    Rhein, B
    Höss, A
    Schlegel, W
    Wannenmacher, M
    RADIOTHERAPY AND ONCOLOGY, 2000, 56 (02) : 227 - 231
  • [49] Rectal dose reduction using three-dimensional conformal radiotherapy for locally advanced prostate cancer: A combination of conformal dynamic-arc and five-static field technique
    Sasaoka, Masahiro
    Nishikawa, Akimasa
    Futami, Tomoyuki
    Nishida, Kouichi
    Miwa, Hiroki
    Kadoya, Kyuuichi
    RADIOTHERAPY AND ONCOLOGY, 2009, 90 (03) : 318 - 324
  • [50] Dose distribution analysis of axillary lymph nodes for three-dimensional conformal radiotherapy with a field-in-field technique for breast cancer
    Ohashi, T.
    Takeda, A.
    Shigematsu, N.
    Fukuda, J.
    Sanuki, N.
    Ameniya, A.
    Kubo, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S177 - S177