Electronic ballast circuit for fluorescent lamps that reduces circuit harmonics

被引:1
|
作者
Shimizu, K [1 ]
Takahashi, Y [1 ]
Kitamura, N [1 ]
机构
[1] Toshiba Lighting & Technol Corp, Tokyo, Japan
来源
关键词
D O I
10.1080/00994480.1997.10748187
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
It has been recognized that harmonic currents flowing out from electric and electronic equipment into commercial power lines cause various problems. An international standard (IEC 1000-3-2) was published in 1995 for reducing the harmonic currents. Consequently, domestic requirements are in preparation. The Japanese lighting industry is going to be in self-imposed control from 1997 according to guidelines based on the IEC standard. Some standard circuit techniques have already been established for reducing the harmonics. It is difficult to apply these techniques for electronic ballasts because of the cost of additional circuitry. Thus, simple and low cost methods for reducing harmonic currents are strongly required. We have developed a combined circuit configuration that has a function of harmonics reduction on a half bridge inverter. Self-excited oscillation is achievable by using a current transformer in the positive feedback circuit. Low in-rush current and low harmonic distortion are realized without increasing the total number of electronic parts compared to the conventional electronic ballast. The circuit presented here was applied. to a highly efficient T8 fluorescent lamp lighting system and has been in commercial use.
引用
收藏
页码:26 / +
页数:6
相关论文
共 50 条
  • [41] Charge pump ballasts as a special type of electronic ballast for fluorescent lamps
    Böhme, F
    Güldner, H
    Raiser, F
    IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 3346 - 3352
  • [42] Constant power control circuit for HID electronic ballast
    Huang, CM
    Liang, TJ
    Lin, RL
    Chen, JF
    CONFERENCE RECORD OF THE 2005 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2005, : 1193 - 1197
  • [43] Electronic ballast circuit operated at unity power factor
    Zuckerberger, A.
    Wild, G.
    Gabbay, J.
    Eichmeier, J.
    EPE Journal (European Power Electronics and Drives Journal), 1995, 5 (02): : 20 - 25
  • [44] A novel ballast for electrodeless fluorescent lamps
    Nerone, LR
    IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 3330 - 3337
  • [45] High frequency reference circuit for CFL/linear fluorescent lamps
    Hammer, E
    Zeke, S
    1996 IESNA ANNUAL CONFERENCE PROCEEDINGS TECHNICAL PAPERS, 1996, : 585 - 603
  • [46] High frequency reference circuit for CFL linear fluorescent lamps
    Hammer, EE
    JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 1997, 26 (02): : 69 - +
  • [47] A MODIFIED CIRCUIT FOR SLIMLINE FLUORESCENT LAMPS FOR PLANT GROWTH CHAMBERS
    PARKER, MW
    BORTHWICK, HA
    PLANT PHYSIOLOGY, 1950, 25 (01) : 86 - 91
  • [48] High frequency reference circuit for CFL/linear fluorescent lamps
    GE Lighting, Cleveland, United States
    J Illum Eng Soc, 2 (69-76):
  • [49] A Novel Circuit of a Single-Switch Electronic Ballast with a Boost-type Resonant Converter Applied to HID Lamps
    Ohsato, Masato H.
    Matsuse, Kouki
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 1466 - 1470
  • [50] TRIPLE-U ELECTRONIC COMPACT FLUORESCENT LAMPS WITH REDUCED HARMONICS
    DEGROOT, JJ
    HOUKES, H
    ROCHE, W
    VAMVAKAS, S
    JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 1994, 23 (01): : 45 - 51