Artifacts Quantification of Metal Implants in MRI

被引:2
|
作者
Vrachnis, I. N. [1 ]
Vlachopoulos, G. F. [1 ]
Maris, T. G. [2 ]
Costaridou, L. I. [1 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Patras, Greece
[2] Univ Crete, Dept Med Phys, Fac Med, Iraklion, Crete, Greece
关键词
SUSCEPTIBILITY ARTIFACTS;
D O I
10.1088/1742-6596/931/1/012007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The presence of materials with different magnetic properties, such as metal implants, causes distortion of the magnetic field locally, resulting in signal voids and pile ups, i.e. susceptibility artifacts in MRI. Quantitative and unbiased measurement of the artifact is prerequisite for optimization of acquisition parameters. In this study an image gradient based segmentation method is proposed for susceptibility artifact quantification. The method captures abrupt signal alterations by calculation of the image gradient. Then the artifact is quantified in terms of its extent by an automated cross entropy thresholding method as image area percentage. The proposed method for artifact quantification was tested in phantoms containing two orthopedic implants with significantly different magnetic permeabilities. The method was compared against a method proposed in the literature, considered as a reference, demonstrating moderate to good correlation (Spearman's rho = 0.62 and 0.802 in case of titanium and stainless steel implants). The automated character of the proposed quantification method seems promising towards MRI acquisition parameter optimization.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
    Hilgenfeld, Tim
    Prager, Marcel
    Schwindling, Franz S.
    Jende, Johann M. E.
    Rammelsberg, Peter
    Bendszus, Martin
    Heiland, Sabine
    Juerchott, Alexander
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (135):
  • [2] Metallic Implants in MRI - Hazards and Imaging Artifacts
    Peschke, Eva
    Ulloa, Patricia
    Jansen, Olav
    Hoevener, Jan-Bernd
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (11): : 1285 - 1293
  • [3] LOW-TESLA MRI IMAGING EFFECTIVELY REDUCES HARDWARE ARTIFACTS IN PATIENTS WITH METAL IMPLANTS
    Alghamdi, Abdulaziz
    Huh, Soon
    Holtzman, Adam
    Indelicato, Danny
    Park, Jiyeon
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S109 - S109
  • [4] Development and evaluation of a numerical simulation approach to predict metal artifacts from passive implants in MRI
    Tobias Spronk
    Oliver Kraff
    Jakob Kreutner
    Gregor Schaefers
    Harald H. Quick
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 485 - 497
  • [5] Development and evaluation of a numerical simulation approach to predict metal artifacts from passive implants in MRI
    Spronk, Tobias
    Kraff, Oliver
    Kreutner, Jakob
    Schaefers, Gregor
    Quick, Harald H.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (03) : 485 - 497
  • [6] Metal-Induced Artifacts in MRI
    Hargreaves, Brian A.
    Worters, Pauline W.
    Pauly, Kim Butts
    Pauly, John M.
    Koch, Kevin M.
    Gold, Garry E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : 547 - 555
  • [7] MRI safety of cardiovascular implants: Evaluation of ferromagnetism, heating, and artifacts
    Shellock, FG
    Shellock, VJ
    RADIOLOGY, 2000, 214 (02) : 614 - 614
  • [8] Quantification of metal-induced susceptibility artifacts associated with ultrahigh-field magnetic resonance imaging of spinal implants
    Chiba, Yusuke
    Murakami, Hideki
    Sasaki, Makoto
    Endo, Hirooki
    Yamabe, Daisuke
    Kinno, Daichi
    Doita, Minoru
    JOR SPINE, 2019, 2 (03):
  • [9] MRI blind zone: A proposed novel index for spinal implants artifacts
    Harel, Ran
    Kimchi, Gil
    Knoller, Nachshon
    CLINICAL IMAGING, 2022, 89 : 78 - 83
  • [10] Integral method for numerical simulation of MRI artifacts induced by metallic implants
    Balac, S
    Caloz, G
    Cathelineau, G
    Chauvel, B
    de Certaines, JD
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) : 724 - 727