Quasi-static testing of concrete masonry shear walls with different horizontal reinforcement schemes

被引:22
|
作者
Calderon, Sebastian [1 ,2 ]
Sandoval, Cristian [1 ,3 ]
Araya-Letelier, Gerardo [4 ]
Inzunza, Ernesto [1 ]
Milani, Gabriele [2 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Struct & Geotech Engn, Casilla 306,Correo 22, Santiago, Chile
[2] Politecn Milan, Dept Architecture Built Environm & Construct Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[3] Pontificia Univ Catolica Chile, Sch Architecture, Casilla 306,Correo 22, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Sch Civil Construct, Casilla 306,Correo 22, Santiago, Chile
来源
JOURNAL OF BUILDING ENGINEERING | 2021年 / 38卷 / 38期
关键词
Partially-grouted; Reinforced masonry; Full-scale test; Bed-joint reinforcement; Bond-beam; Horizontal reinforcement layout; Cyclic test; DEFORMATION MEASUREMENT; CYCLIC RESPONSE; BOND BEHAVIOR; BUILDINGS; CAPACITY; ARCHES; SRG; TRM;
D O I
10.1016/j.jobe.2021.102201
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Constructions built with partially grouted reinforced masonry (PG-RM) shear walls are common in several countries, and consequently, different construction solutions can be expected. In this context, one of the main differences detected is the type of horizontal steel reinforcement used. The most traditional options consist of bed-joint reinforcement and bond-beam reinforcement. Despite the advances in this research area, there is little experimental evidence to determine which of these horizontal reinforcement schemes exhibits a superior performance under seismic loads. Thus, the research described in this paper focused on assessing and comparing the seismic performance of PG-RM shear walls with different horizontal reinforcement options. For this purpose, four concrete masonry walls with an aspect ratio of 0.86 were tested undergoing constant axial pre-compression and quasi-static cyclic incremental lateral displacements. The tested walls had the same horizontal reinforcement ratio but different layouts (only bed joint reinforcement, only bond beam reinforcement, and a combination of them). The other design characteristics remained constant. The obtained results were analyzed in terms of the force-displacement curves and seismic performance parameters such as the maximum resistance, stiffness decay, energy dissipation, and equivalent viscous damping ratio. In addition, a comparative analysis of damage progression of the tested walls was carried out using the digital image correlation (DIC) technique. The tested walls experienced progressive deterioration of the lateral stiffness in proportion to drift increments regardless of the reinforcement scheme. Once achieved the lateral resistance, the degradation of the behavior accelerated, turning into a rather unpredictable response. Employing different horizontal reinforcement layout showed no influence on the lateral capacity of the walls when the same horizontal reinforcement ratio and material qualities are used. It was also observed that the distributed bed-joint reinforcement was better than the bond-beam reinforcement layout in controlling crack widths. Additionally, a combination of bond-beams and bed-joint reinforcement seems to be the most suitable reinforcement strategy based on hysteretic behavior, energy dissipation capacity, and ductility. The presented experimental evidence is promising, although further studies are required in order to promote its use in design codes and construction projects.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Experimental study on L-shaped precast concrete superposed shear walls under quasi-static cyclic loading with different axial compressive load ratios
    Gu, Qian
    Zhao, Duanfeng
    Tan, Yuan
    Gao, Hongyuan
    Deng, Qing
    Wang, Xiang
    ENGINEERING STRUCTURES, 2022, 254
  • [42] Experimental study of in-plane shear strength of confined concrete masonry walls with joint reinforcement
    Cruz O, A. I.
    Perez-Gavilan E, J. J.
    Flores C, L.
    ENGINEERING STRUCTURES, 2019, 182 : 213 - 226
  • [43] Quasi-static experiments on steel plate shear walls reinforced with X-shaped restrainers
    Cao, Zhenggang
    Wang, Zhicheng
    Du, Peng
    Liu, Han
    Fan, Feng
    JOURNAL OF BUILDING ENGINEERING, 2020, 31 (31)
  • [44] Quasi-static loading procedure of CFS framed shear walls considering ground motion duration
    Wang, Xingxing
    Wei, Wang
    Yang, Jinrui
    Wu, Yutian
    STRUCTURES, 2023, 56
  • [45] Response of nonconforming RC shear walls with smooth bars under quasi-static cyclic loading
    Olabi, Muhammed Nadir
    Caglar, Naci
    Arslan, Mehmet Emin
    Ozturk, Hakan
    Demir, Aydin
    Dok, Gokhan
    Aykanat, Batuhan
    BULLETIN OF EARTHQUAKE ENGINEERING, 2022, 20 (12) : 6683 - 6704
  • [46] Response of nonconforming RC shear walls with smooth bars under quasi-static cyclic loading
    Muhammed Nadir Olabi
    Naci Caglar
    Mehmet Emin Arslan
    Hakan Ozturk
    Aydin Demir
    Gokhan Dok
    Batuhan Aykanat
    Bulletin of Earthquake Engineering, 2022, 20 : 6683 - 6704
  • [47] Performance of bamboo reinforced concrete masonry shear walls
    Moroz, J. G.
    Lissel, S. L.
    Hagel, M. D.
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 61 : 125 - 137
  • [48] INELASTIC BEHAVIOR OF CONCRETE MASONRY SHEAR WALLS - CLOSURE
    SHING, PB
    NOLAND, JL
    KLAMERUS, E
    SPAEH, H
    JOURNAL OF STRUCTURAL ENGINEERING, 1991, 117 (09) : 2807 - 2808
  • [49] INELASTIC BEHAVIOR OF CONCRETE MASONRY SHEAR WALLS - DISCUSSION
    GALLEGOS, H
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1991, 117 (09): : 2804 - 2805
  • [50] Experimental investigation on dynamic and quasi-static behavior of low-rise reinforced concrete walls
    Carrillo, Julian
    Alcocer, Sergio M.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2013, 42 (05): : 635 - 652