Quasi-static testing of concrete masonry shear walls with different horizontal reinforcement schemes

被引:22
|
作者
Calderon, Sebastian [1 ,2 ]
Sandoval, Cristian [1 ,3 ]
Araya-Letelier, Gerardo [4 ]
Inzunza, Ernesto [1 ]
Milani, Gabriele [2 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Struct & Geotech Engn, Casilla 306,Correo 22, Santiago, Chile
[2] Politecn Milan, Dept Architecture Built Environm & Construct Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[3] Pontificia Univ Catolica Chile, Sch Architecture, Casilla 306,Correo 22, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Sch Civil Construct, Casilla 306,Correo 22, Santiago, Chile
来源
JOURNAL OF BUILDING ENGINEERING | 2021年 / 38卷 / 38期
关键词
Partially-grouted; Reinforced masonry; Full-scale test; Bed-joint reinforcement; Bond-beam; Horizontal reinforcement layout; Cyclic test; DEFORMATION MEASUREMENT; CYCLIC RESPONSE; BOND BEHAVIOR; BUILDINGS; CAPACITY; ARCHES; SRG; TRM;
D O I
10.1016/j.jobe.2021.102201
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Constructions built with partially grouted reinforced masonry (PG-RM) shear walls are common in several countries, and consequently, different construction solutions can be expected. In this context, one of the main differences detected is the type of horizontal steel reinforcement used. The most traditional options consist of bed-joint reinforcement and bond-beam reinforcement. Despite the advances in this research area, there is little experimental evidence to determine which of these horizontal reinforcement schemes exhibits a superior performance under seismic loads. Thus, the research described in this paper focused on assessing and comparing the seismic performance of PG-RM shear walls with different horizontal reinforcement options. For this purpose, four concrete masonry walls with an aspect ratio of 0.86 were tested undergoing constant axial pre-compression and quasi-static cyclic incremental lateral displacements. The tested walls had the same horizontal reinforcement ratio but different layouts (only bed joint reinforcement, only bond beam reinforcement, and a combination of them). The other design characteristics remained constant. The obtained results were analyzed in terms of the force-displacement curves and seismic performance parameters such as the maximum resistance, stiffness decay, energy dissipation, and equivalent viscous damping ratio. In addition, a comparative analysis of damage progression of the tested walls was carried out using the digital image correlation (DIC) technique. The tested walls experienced progressive deterioration of the lateral stiffness in proportion to drift increments regardless of the reinforcement scheme. Once achieved the lateral resistance, the degradation of the behavior accelerated, turning into a rather unpredictable response. Employing different horizontal reinforcement layout showed no influence on the lateral capacity of the walls when the same horizontal reinforcement ratio and material qualities are used. It was also observed that the distributed bed-joint reinforcement was better than the bond-beam reinforcement layout in controlling crack widths. Additionally, a combination of bond-beams and bed-joint reinforcement seems to be the most suitable reinforcement strategy based on hysteretic behavior, energy dissipation capacity, and ductility. The presented experimental evidence is promising, although further studies are required in order to promote its use in design codes and construction projects.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Quasi-static tests of squat reinforced concrete shear walls with openings
    Xu, Guoshan
    Zheng, Lichang
    Zhou, Wei
    Zhai, Changhai
    Wang, Dongmei
    [J]. ENGINEERING STRUCTURES, 2023, 293
  • [2] Joint Reinforcement as Primary Shear Reinforcement for Concrete Masonry Shear Walls
    Baenziger, Greg
    Porter, Max L.
    [J]. MASONRY SOCIETY JOURNAL, 2018, 36 (01): : 49 - +
  • [3] Quasi-static testing of composite masonry construction
    Hu, W
    Hu, MG
    He, Q
    [J]. BUILDING RESEARCH AND INFORMATION, 1999, 27 (02): : 120 - 123
  • [4] Study of Autoclaved Aerated Concrete Masonry Walls with Horizontal Reinforcement under Compression and Shear
    Jasinski, Radoslaw
    Drobiec, Lukasz
    [J]. WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM 2016, WMCAUS 2016, 2016, 161 : 918 - 924
  • [5] Behavior of Partially Grouted Concrete Masonry Walls under Quasi-Static Cyclic Lateral Loading
    Calderon, Sebastian
    Vargas, Laura
    Sandoval, Cristian
    Araya-Letelier, Gerardo
    [J]. MATERIALS, 2020, 13 (10)
  • [6] Quasi-static Test of Reinforced Concrete Shear Wall with Low Concrete Strength and Reinforcement Ratio
    Deng Kailai
    Pan Peng
    Shi Yuanyuan
    Miao Qisong
    Li Wenfeng
    Wang Tao
    [J]. APPLIED MECHANICS AND CIVIL ENGINEERING II, 2012, 188 : 106 - +
  • [7] Quasi-static cyclic tests on super-lightweight EPS concrete shear walls
    Mousavi, Seyed Amin
    Zahrai, Seyed Mehdi
    Bahrami-Rad, Asghar
    [J]. ENGINEERING STRUCTURES, 2014, 65 : 62 - 75
  • [8] Quasi-static cyclic testing of partially grouted masonry walls with openings-preliminary results
    Fortes, E. S.
    Silva, M. R.
    Parsekian, G. A.
    Fonseca, F. S.
    Shrive, N. G.
    [J]. BRICK AND BLOCK MASONRY: TRENDS, INNOVATIONS AND CHALLENGES, 2016, : 187 - 194
  • [9] Quasi-Static Testing of RC Infilled Frames and Confined Stone-Concrete Bearing Walls
    Al-Nimry, Hanan S.
    [J]. JOURNAL OF EARTHQUAKE ENGINEERING, 2014, 18 (01) : 1 - 23
  • [10] Quasi-static, cyclic loading tests of RAC brick masonry walls strengthened by basalt textile reinforced concrete
    Wan, Chenglin
    Wang, Jiyang
    Zeng, Qiang
    Shen, Linghua
    Liu, Chengbin
    [J]. COMPOSITE STRUCTURES, 2023, 321