Thick CZT detectors for space-borne x-ray astronomy

被引:14
|
作者
Krawczynski, H [1 ]
Jung, I [1 ]
Perkins, J [1 ]
Burger, A [1 ]
Groza, M [1 ]
机构
[1] Washington Univ, Dept Phys, St Louis, MO 63130 USA
关键词
C ZT; X-ray and Gamma-ray detectors; space-applications; contact technology;
D O I
10.1117/12.558912
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. Without the need for cryogenic cooling they achieve good spatial and energy resolutions over the broad energy range from 10 keV to similar to600 keV. In this paper, we briefly review the historical development of detectors used in Xray astronomy. Subsequently, we present an evaluation of CZT detectors from the company Imarad. The standard 2x2x0.5 cm detectors, contacted with 8x8 In pixels and an In cathode, exhibit FWHM energy resolutions of 7 keV at 59 keV, and 10 keV at 662 keV. A direct measurement of the 662 keV photopeak efficiency gives 67%. We have started a detailed study of the performance of Imarad detectors depending on surface preparation, contact materials, contact deposition, post-deposition detector annealing, and detector passivation techniques. We present first results from contacting detectors with Cr, Ag, Au, and Pt.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [21] ACTIVATION OF SPACE-BORNE BISMUTH-GERMANATE GAMMA-RAY DETECTORS
    TRUSCOTT, PR
    DYER, CS
    HASKINS, PS
    MCKISSON, JE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 946 - 955
  • [22] Improved x-ray spectroscopy with room temperature CZT detectors
    Fritz, Shannon G.
    Shikhaliev, Polad M.
    Matthews, Kenneth L., II
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17): : 5735 - 5751
  • [23] Prospects of hard X-ray polarimetry with pixillated CZT detectors
    Vadawale, Santosh
    PROCEEDINGS OF THE 31ST MEETING OF THE ASTRONOMICAL SOCIETY OF INDIA, 2013, 2013, : 98 - 98
  • [24] Goniopolarimetry: Space-borne radio astronomy with imaging capabilities
    Cecconi, Baptiste
    COMPTES RENDUS PHYSIQUE, 2014, 15 (05) : 441 - 447
  • [25] POSITION-SENSITIVE DETECTORS IN X-RAY ASTRONOMY
    CULHANE, JL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 1 - 13
  • [26] Novel semiconductor detectors for X-ray astronomy and spectroscopy
    Lutz, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 501 (01): : 288 - 297
  • [27] CALIBRATION OF SI(LI) DETECTORS FOR X-RAY ASTRONOMY
    LOCHNER, JC
    BOLDT, EA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 242 (03): : 382 - 386
  • [28] Low-temperature detectors in X-ray astronomy
    Porter, FS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 354 - 358
  • [29] Micromachined X-ray collector for space astronomy
    Ezoe, Yuichiro
    Koshiishi, Masaki
    Mita, Makoto
    Maeda, Yoshitomo
    Mitsuda, Kazuhisa
    Osawa, Takeyuki
    Suzuki, Masaki
    Hoshino, Akio
    Ishisaki, Yoshitaka
    Takano, Takayuki
    Maeda, Ryutaro
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 145 : 201 - 206
  • [30] A micromachined X-ray collector for space astronomy
    Ezoe, Y.
    Koshiishi, M.
    Mita, M.
    Maeda, Y.
    Mitsuda, K.
    Osawa, T.
    Suzuki, M.
    Hoshino, A.
    Ishisaki, Y.
    Takano, T.
    Maeda, R.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,