Study on a silica gel-water adsorption chiller integrated with a closed wet cooling tower

被引:25
|
作者
Chen, C. J. [1 ]
Wang, R. Z. [1 ]
Xia, Z. Z. [1 ]
Kiplagat, J. K. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
关键词
Silica gel; Water; Adsorption; Refrigeration; Cooling tower; COMPUTATIONAL ANALYSIS; MASS-TRANSFER; HEAT;
D O I
10.1016/j.ijthermalsci.2009.09.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
A silica gel-water adsorption chiller integrated with a closed wet cooling tower is proposed. This adsorption chiller consists of two vacuum chambers, each with one adsorber, one condenser and one evaporator. Vacuum valves were not adopted in this chiller in order to enhance the reliability. A novel heat recovery process was carried out after a mass recovery-like process to improve the coefficient of performance (COP). Integration of the closed wet cooling tower into the chiller could ensure the cleanliness of cooling water circulating in the chiller and also promote the convenient setup of the chiller. A transient one-dimensional mathematical model was adopted to study this adsorption chiller. The simulated results showed that the cooling power and COP were 10.76 kW and 0.51 respectively when the hot water inlet temperature, the chilled water inlet temperature, the air inlet wet bulb temperature and dry bulb temperature were 85, 15, 28 and 30 degrees C respectively. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:611 / 620
页数:10
相关论文
共 50 条
  • [41] Physical and operating conditions effects on silica gel/water adsorption chiller performance
    Rezk, Ahmed R. M.
    Al-Dadah, Raya K.
    [J]. APPLIED ENERGY, 2012, 89 (01) : 142 - 149
  • [42] A new generation cooling device employing CaCl2-in-silica gel-water system
    Saha, Bidyut Baran
    Chakraborty, Anutosh
    Koyama, Shigeru
    Aristov, Yu I.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (1-2) : 516 - 524
  • [43] Experimental study of silica gel/water adsorption cooling system using a modified adsorption bed
    Khalil, Alsaied
    El-Agouz, El-Sayed A.
    El-Samadony, Yasser A. F.
    Sharaf, Maisa A.
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (01) : 41 - 49
  • [44] Thermodynamic Investigation on the Performance of Closed Wet Cooling Tower
    Fang, Jiamei
    Zhao, Xuhui
    Zhang, Lin
    Bu, Shi
    Yu, Zhikang
    Xu, Weigang
    Hu, Yiyang
    Shan, Yanfei
    Li, Yong
    [J]. JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2022, 14 (03)
  • [45] Thermal performance analysis of a closed wet cooling tower
    Papaefthimiou, V. D.
    Zannis, T. C.
    Rogdakis, E. D.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2007, 221 (E3) : 139 - 150
  • [46] Photochemical oxidation of chrysene at the silica gel-water interface
    Kong, L
    Ferry, JL
    [J]. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2004, 162 (2-3) : 415 - 421
  • [47] Experimental investigation of silica gel-water adsorption chillers with and without a passive heat recovery scheme
    Wang, XL
    Chua, HT
    Ng, KC
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (05): : 756 - 765
  • [48] Experimental investigation of an adsorption air-conditioner using silica gel-water working pair
    Pan, Quanwen
    Peng, Jiajie
    Wang, Hongbin
    Sun, Haiquan
    Wang, Ruzhu
    [J]. SOLAR ENERGY, 2019, 185 : 64 - 71
  • [49] Experimental study on an adsorption chiller employing lithium chloride in silica gel and methanol
    Gong, L. X.
    Wang, R. Z.
    Xia, Z. Z.
    Lu, Z. S.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (07): : 1950 - 1957
  • [50] Experimental evaluation of Adsorption Heat for Water vapour/Silica gel pair for chiller application
    Khan, Mohd Abdullah
    Thu, Kyaw
    Mitra, Sourav
    [J]. APPLIED THERMAL ENGINEERING, 2024, 249