Esophageal thermal lesions in radiofrequency ablation for atrial fibrillation: A prospective comparative study of thermal sensors

被引:0
|
作者
Arai, Shuhei [1 ]
Watanabe, Norikazu [2 ]
Sugiyama, Hiroto [1 ]
Gokan, Toshihiko [1 ]
Yoshikawa, Kosuke [1 ]
Nakamura, Yuya [1 ]
Inokuchi, Koichiro [1 ]
Chiba, Yuta [1 ]
Onishi, Yoshimi [1 ]
Onuki, Tatsuya [1 ]
Asano, Taku [1 ]
Kobayashi, Youichi [3 ]
Shinke, Toshiro [1 ]
机构
[1] Showa Univ, Dept Med, Div Cardiol, Sch Med, Tokyo, Japan
[2] Kanto Rosai Hosp, Dept Cardiovasc Med, Kawasaki, Kanagawa, Japan
[3] Showa Univ Hosp, Div Med Safety, Tokyo, Japan
来源
关键词
atrial fibrillation; atrio-esophageal fistula; catheter ablation; esophageal injury; esophageal thermal lesion; esophageal thermal monitoring; PULMONARY VEIN ISOLATION; CATHETER ABLATION; TIME;
D O I
10.1111/pace.14551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Esophageal thermal lesion (ETL) is a complication of radiofrequency ablation for atrial fibrillation (RFAF). To prospectively compare the incidence of ETL, we used two linear, five- and three-sensor esophageal thermal monitoring catheters (ETMC5 and ETMC3). We also evaluated the predictors of ETL. Methods Patients receiving their first RFAF (n = 106) were randomized into two groups, ETMC5 (n = 52) and ETMC3 (n = 54). Ablation was followed by esophagogastroduodenoscopy within 3 days. Results Esophageal thermal lesion was detected in 7/106 (6.6%) patients (ETMC5: 3/52 [5.8%] vs. ETMC3: 4/54 [7.4%]; p = 1.0). The maximum temperature and number of measurements > 39.0 degrees C did not differ between the groups (ETMC5: 40.5 degrees C and 5.4 vs. ETMC3: 40.6 degrees C and 4.9; p = .83 and p = .58, respectively). In ETMC5 group, the catheter had to be moved significantly less often (0.12 vs. 0.42; p = .0014) and fluoroscopy time was significantly shorter (79.2 min vs. 101.7 min; p = .0038) compared with ECMC3 group. The total number of ablations in ETMC5 group was significantly greater (50.2 vs. 37.7; p = .030) and ablation time was significantly longer (52.1 min vs. 40.1 min; p = .0039). Only body mass index (BMI) was significantly different between patients with and without ETL (21.4 +/- 2.5 vs. 24.3 +/- 3.4; p = .022). Conclusions The incidence of ETL was comparable between ETMC5 and ETMC3 groups; however, fluoroscopy time, total ablation time, and total number of ablations differed significantly. Lower BMI may increase the risk of developing ETL.
引用
收藏
页码:913 / 921
页数:9
相关论文
共 50 条
  • [41] Active esophageal cooling for the prevention of thermal injury during atrial fibrillation ablation: a randomized controlled pilot study
    Tschabrunn, Cory M.
    Attalla, Sara
    Salas, Jonathan
    Frankel, David S.
    Hyman, Matthew C.
    Simon, Emily
    Sharkoski, Tiffany
    Callans, David J.
    Supple, Gregory E.
    Nazarian, Saman
    Lin, David
    Schaller, Robert D.
    Dixit, Sanjay
    Marchlinski, Francis E.
    Santangeli, Pasquale
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 63 (01) : 197 - 205
  • [42] Time course of esophageal lesions after catheter ablation with cryothermal and radiofrequency ablation: Implication for atrio-esophageal fistula formation after catheter ablation for atrial fibrillation
    Ripley, Kenneth Lauren
    Gage, Andrew A.
    Olsen, Don B.
    Van Vleet, John F.
    Lau, Chu-Pak
    Tse, Hung-Fat
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (06) : 642 - 646
  • [43] Thyroid Nodules Treated with Percutaneous Radiofrequency Thermal Ablation: A Comparative Study
    Faggiano, A.
    Ramundo, V.
    Assanti, A. P.
    Fonderico, F.
    Macchia, P. E.
    Misso, C.
    Marciello, F.
    Marotta, V.
    Del Prete, M.
    Papini, E.
    Lombardi, G.
    Colao, A.
    Spiezia, S.
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2012, 97 (12): : 4439 - 4445
  • [44] Impact of paroxysmal atrial fibrillation ablation on cardiac sympathetic nervous system: a prospective randomized comparative study with cryoballoon catheter or radiofrequency ablation catheter
    Kawasaki, M.
    Yamada, T.
    Morita, T.
    Furukawa, Y.
    Tamaki, S.
    Iwasaki, Y.
    Kikuchi, A.
    Kawai, T.
    Seo, M.
    Ikeda, I.
    Fukuhara, E.
    Abe, M.
    Nakamura, J.
    Fukunami, M.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1415 - 1415
  • [45] Prospective randomized comparison of left atrial and biatrial radiofrequency ablation in the treatment of atrial fibrillation
    Wang, Jiangang
    Meng, Xu
    Li, Hui
    Cui, Yongqiang
    Han, Jie
    Xu, Chunlei
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (01) : 116 - 122
  • [46] Progression of Esophageal Injury after Radiofrequency Catheter Ablation for Atrial Fibrillation.
    Contreras-Valdes, Fernando
    Heist, E. Kevin
    Danik, Stephan B.
    Barrett, Conor D.
    Ruskin, Jeremy N.
    Mansour, Moussa
    CIRCULATION, 2010, 122 (21)
  • [47] Atrio-Esophageal Fistula Fatal Complication of Radiofrequency Ablation of Atrial Fibrillation
    Nandavaram, Sravanthi
    CHEST, 2014, 145 (03)
  • [48] Radiofrequency catheter ablation for atrial fibrillation
    Jaïs, P
    Shah, DC
    Hocini, M
    Yamane, T
    Haïssaguerre, M
    Clémenty, J
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (07) : 758 - +
  • [49] Radiofrequency Ablation in Treatment of Atrial Fibrillation
    Labrova, R.
    Spinar, J.
    Honzikova, N.
    PHYSIOLOGICAL RESEARCH, 2010, 59 : S43 - S49
  • [50] Luminal esophageal temperature monitoring to reduce esophageal thermal injury during catheter ablation for atrial fibrillation: A review
    Kadado, Anis John
    Akar, Joseph G.
    Hummel, James R.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2019, 29 (05) : 264 - 271