3-d view weighted cone-beam filtered backprojection reconstruction for digital tomosynthesis

被引:6
|
作者
Li, Baojun [1 ]
Avinash, Gopal [1 ]
Claus, Bernhard [2 ]
Metz, Stephen [3 ]
机构
[1] Gen Elect Healthcare, Appl Sci Lab, Waukesha, WI 53188 USA
[2] Gen Elect, Global Res Ctr, Niskayuna, NY 12309 USA
[3] Gen Elect Healthcare, Diagnost Xray Engn, Waukesha, WI 53188 USA
关键词
tomosynthesis; filtered backprojection; view weighting; cone beam; artifact;
D O I
10.1117/12.708084
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cone-beam filtered backprojection (CB-FBP) is one of the major reconstruction algorithms for digital tomosynthesis. In conventional FBP, the photon fluxes in projections are evenly distributed along the X-ray beam. Due to the limited view angles and finite detector dimensions, this uniform weighting causes non-uniformity in the recon images and leads to cone-beam artifact. In this paper, we propose a 3-D view weighting technique in combination with FBP to combat this artifact. An anthropomorphic chest phantom was placed at supine position to enable the imaging of chest PA view. During a linear sweep of X-ray source, 41 X-ray images at different projection angles were acquired with the following protocol: 120kVp, 160mA, and 0.64mAs/exposure. To create the worst scenario for testing, we chose 60 degrees as the sweep angle in this exam. The data set was reconstructed with conventional CB-FBP and proposed algorithm under the same parameters: FOV = 40x40 cm boolean AND 2, and slice thickness = 4mm. 3 recon slices were randomly selected for review with slice height = 10.5/14.5/17.5cm. Results were assessed qualitatively by human observers and quantitatively through ROI measurement. In each slice, three pre-defined ROIs (50x50 pixels)--ROI A and B are in artifact more pronounced area, and ROI C is in relatively artifact-free area-are extracted and measured. The non-uniformity error was defined as the ratio of MEAN(AVG(C-A), AVG(C-B)) / AVG(C). The average non-uniformity error over the three test images was 0.428 for without view weighting and only 0.041 for with view weighting.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A helical cone beam filtered backprojection (CB-FBP) reconstruction algorithm using three-dimensional (3D) view weighting
    Tang, XY
    Hsieh, J
    Nilsen, RA
    Dutta, S
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 577 - 587
  • [32] A parallel backprojection algorithm for spiral cone-beam ct exact reconstruction
    Xue G.
    Zhang Y.
    International Journal of Digital Content Technology and its Applications, 2010, 4 (06) : 134 - 143
  • [33] New approximate filtered backprojection algorithm for helical cone-beam CT with redundant data
    Kudo, H
    Noo, F
    Defrise, M
    Rodet, T
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3211 - 3215
  • [34] Fast and stable cone-beam filtered backprojection method for non-planar orbits
    Kudo, H
    Saito, T
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 747 - 760
  • [35] A CONE-BEAM FILTERED BACKPROJECTION RECONSTRUCTION ALGORITHM FOR CARDIAC SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY - COMMENT
    WANG, G
    LIN, TH
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) : 383 - 384
  • [36] Cone-beam convolution 3D reconstruction
    Yang, H
    Sun, HY
    Wang, C
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 7925 - 7927
  • [37] A backprojection filtered image reconstruction algorithm for circular cone-beam CT - art. no. 61424N
    Li, Liang
    Chen, Zhiqiang
    Zhang, Li
    Xing, Yuxiang
    Kang, Kejun
    Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : N1424 - N1424
  • [38] Nonseparable wavelet-based cone-beam reconstruction in 3-D rotational angiography
    Bonnet, S
    Peyrin, F
    Turjman, F
    Prost, R
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (03) : 360 - 367
  • [39] Performance evaluation of the backprojection filtered (BPF) algorithm in circular fan-beam and cone-beam CT
    LI Liang CHEN Zhi-Qiang ZHANG Li KANG Ke-Jun Department of Engineering Physics
    NuclearScienceandTechniques, 2006, (02) : 113 - 117
  • [40] Cone-beam CT reconstruction using a nonlinear weighted filtered backprojection from half-scan data - art. no. 61424Y
    Gomi, Tsutomu
    Koshida, Kichrou
    Miyati, Tosiaki
    Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : Y1424 - Y1424