A sensitive assay for ZYAN1 in human whole blood and urine utilizing positive LC-MS/MS electrospray ionization

被引:1
|
作者
Patel, Harilal [1 ]
Soni, Krunal [1 ]
Trivedi, Rucha [1 ]
Heading, Heather [2 ]
Geue, Jason [2 ]
Kansagra, Kevinkumar [3 ]
Gupta, Rahul J. [3 ]
Pandya, Vrajesh B. [4 ]
Srinivas, Nuggehally R. [1 ]
Patel, Pankaj R. [1 ,3 ,4 ]
Desai, Ranjit C. [4 ]
机构
[1] Zydus Res Ctr, Bioanalyt Lab, Ahmadabad 382210, Gujarat, India
[2] CPR Pharma Serv, Thebarton, SA 5031, Australia
[3] Zydus Res Ctr, Clin Res, Ahmadabad 382210, Gujarat, India
[4] Zydus Res Ctr, Med Chem, Ahmadabad 382210, Gujarat, India
关键词
anemia; LC-MS/MS; method validation; pharmacokinetics; prolyl hydroxylase inhibitors; whole blood; ZYAN1; PROLYL HYDROXYLASE INHIBITOR; ROXADUSTAT FG-4592; ANEMIA; HYPOXIA; DISEASE; ALPHA;
D O I
10.4155/bio-2017-0014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aim: A sensitive LC-MS/MS method was developed and validated for estimation of ZYAN1 in human blood/urine. Methods: An analog internal standard IOX2 along with ZYAN1 was quantified using selective reaction monitoring in positive mode. The chromatographic separation was performed by gradient elution with C-18 analytical column (3 mu m, 50 mm x 2.0 mm) with 4-min run time using an acidified mobile phase consisting of ammonium formate and acetonitrile. Protein precipitation enabled extraction of analytes from diluted blood/urine. Results: Calibration curve of ZYAN1 was linear (2-5000 ng/ml). The recovery of ZYAN1 and IOX2 was between 87 and 104%. Interday and intraday accuracy and precision was found well within the acceptance criteria. Conclusion: The validated assay was applied for clinical pharmacokinetics of ZYAN1 in healthy volunteers.
引用
收藏
页码:719 / 732
页数:14
相关论文
共 50 条
  • [1] Estimation of ZYKR1 in human urine and plasma utilizing LC-MS/MS positive electrospray ionization; a kappa opioid receptor (KOR) agonist
    Ghoghari, Ashok
    Bhatt, Chandrakant
    Patel, Kuldip
    Jha, Anil
    Patel, Harilal
    Jain, Mukul
    Momin, Taufik
    Parmar, Deven
    Patel, Pankaj
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1185
  • [2] Tips for Electrospray Ionization LC-MS
    Taylor, Tony
    LC GC NORTH AMERICA, 2021, 39 (01) : 42 - 42
  • [3] Development and validation of a sensitive assay for the quantification of imatinib using LC/LC-MS/MS in human whole blood and cell culture
    Klawitter, Jelena
    Zhang, Yan Ling
    Klawitter, Jost
    Anderson, Nora
    Serkova, Natalie J.
    Christians, Uwe
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (12) : 1251 - 1258
  • [4] Sensitive LC-MS assay for the determination of the antimalarial pyronaridine in human blood
    Naik, Himanshu
    Imming, Paul
    Murry, Daryl J.
    Fleckenstein, Lawrence
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2006, 75 (05): : 220 - 220
  • [5] Sensitive and specific LC-MS assay for quantification of digoxin in human plasma and urine
    Kirby, Brian J.
    Kalhorn, Tom
    Hebert, Mary
    Easterling, Tom
    Unadkat, Jashvant D.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (07) : 712 - 718
  • [6] Multiplexed LC-MS/MS Assay for Urine Albumin
    Beasley-Green, Ashley
    Burris, Nijah M.
    Bunk, David M.
    Phinney, Karen W.
    JOURNAL OF PROTEOME RESEARCH, 2014, 13 (09) : 3930 - 3939
  • [7] Quantitative determination of saroglitazar, a predominantly PPAR alpha agonist, in human plasma by a LC-MS/MS method utilizing electrospray ionization in a positive mode
    Ghoghari, Ashok
    Dash, Ranjeet
    Bhatt, Chandrakant
    Singh, Kanchan
    Jha, Anil
    Patel, Harilal
    Gupta, Rahul
    Kansagra, Kevinkumar
    Srinivas, Nuggehally R.
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (12) : 1900 - 1907
  • [8] In electrospray ionization source hydrogen/deuterium exchange LC-MS and LC-MS/MS for characterization of metabolites
    Lam, W
    Ramanathan, R
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (04) : 345 - 353
  • [9] LC-MS/MS assay for biomarkers of furan exposure and metabolism in human urine
    Grill, Alexander E.
    Gates, Leah
    Peterson, Lisa
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 246
  • [10] A validated surrogate analyte LC-MS/MS assay for quantification of endogenous cortisol in human whole blood
    Agrawal, Karan
    Voggu, Ramakrishna R.
    Pisek, Daniel
    Becht, Steven
    Chudnovskiy, Ross
    Dufour, Geraldine Mercier
    Arfvidsson, Cecilia
    Thomas, C. Eric
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 198