Multilayered artificial neural network for performance prediction of an adiabatic solar liquid desiccant dehumidifier

被引:6
|
作者
Oyieke, Andrew Y. A. [1 ]
Inambao, Freddie L. [1 ]
机构
[1] Univ KwaZulu Natal, Discipline Mech Engn, Mazisi Kunene Rd, ZA-4041 Durban, South Africa
关键词
Adiabatic dehumidifier; liquid desiccant; solar; artificial neural network;
D O I
10.1093/ijlct/ctz022
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, a multi-layered artificial neural network (ANN) algorithm was developed and trained to predict the performance of a solar powered liquid desiccant air conditioning (LDAC) system particularly the adiabatic packed tower dehumidifier using Lithium Bromide (LiBr) desiccant. A reinforced technique of supervised learning based on error correction principle rule coupled with perceptron convergence theorem was applied to create the algorithm. The parameters such as temperature, flow rates and humidity ratio of both air and desiccant fluid were fed as inputs to the ANN algorithm and their respective outputs used to determine dehumidifier effectiveness and moisture removal rate (MRR). The ANN model when subjected to validity tests using vapour pressure of LiBr desiccant solution at specific random temperatures and concentrations, gave astounding outcomes with precise estimation to R-2 values of 0.9999 for all desiccant concentration levels. Due to the variation in solar radiation, the MRR and effectiveness fluctuated with the change in desiccant and air temperatures, giving maximum differences of 0.2 g/s and 1.8% respectively between the predicted and measured values depicting a perfect match. With respect to humidity ratio, MRR was accurately predicted by ANN algorithm with maximum difference of 3.4969% while the mean variation was -0.5957%. With respect to air temperature, the dehumidifier effectiveness was perfectly predicted by the ANN algorithm to an average accuracy of 0.53% and extreme positive deviation of 4.14%. The MRR was replicated to a mean variation of 0.013% and highest point difference of 0.08%. In all the above cases, the mean and maximum differences between the ANN model and experimental values were far below the allowable limit of +/- 5%, hence the algorithm was deemed to be successful and could find use in air conditioning scenarios. The ANN algorithm's capability and flexibility test of processing unforeseen inputs was accurate with negligible deviations and prospects of predicting the desiccant's vapour pressure, dehumidifier effectiveness and MRR within all ranges of temperature and concentration which then eliminates the need for use of charts.
引用
收藏
页码:351 / 363
页数:13
相关论文
共 50 条
  • [31] A novel method to evaluate the performance of liquid desiccant air dehumidifier system
    Bakhtiar, Agung
    Rokhman, Fatkhur
    Choi, Kwang Hwan
    ENERGY AND BUILDINGS, 2012, 44 : 39 - 44
  • [32] SOLAR COOLING SYSTEMS - MASS-TRANSFER STUDIES FOR A LIQUID DESICCANT DEHUMIDIFIER
    FLAHERTY, M
    LENZ, TG
    LOF, GOG
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1991, 15 (08) : 679 - 688
  • [33] An experimental study on the dehumidification performance of a counter flow liquid desiccant dehumidifier
    Wang, Lingshi
    Xiao, Fu
    Zhang, Xuejun
    Kumar, Ritunesh
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 70 : 289 - 301
  • [34] Performance analysis of liquid desiccant dehumidifier system for various packing density
    Sonowal, Juri
    Mahajan, Mahesh
    Muthukumar, P.
    Anandalakshmi, R.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 38
  • [35] Critical review of coupled heat and mass transfer models for a liquid desiccant adiabatic dehumidifier and regenerator
    Koronaki, I. P.
    Christodoulaki, R. I.
    Papaefthimiou, V. D.
    Rogdakis, E. D.
    ADVANCES IN BUILDING ENERGY RESEARCH, 2014, 8 (02) : 117 - 136
  • [36] CFD simulation of liquid desiccant dehumidifier performance with smooth and rough plates
    Lu, Hao
    Lu, Lin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 124 : 1 - 12
  • [37] Performance numerical analysis on an internally-cooled liquid desiccant dehumidifier
    Chan, X. M.
    Liu, X. H.
    Jiang, Y.
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 607 - 613
  • [38] Performance Evaluation of Packed Tower Liquid Desiccant Dehumidifier Based on LSSVM
    Wang, Xinli
    Lu, Jiangang
    Yang, Qinmin
    Cai, Wenjian
    Sun, Youxian
    2013 10TH IEEE INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION (ICCA), 2013, : 987 - 990
  • [39] Optimization of a multistage liquid desiccant dehumidifier by neural networks & particle swarm techniques
    Salins, Sampath Suranjan
    Kumar, Shiva
    Ganesha, A.
    Reddy, S. V. Kota
    JOURNAL OF BUILDING ENGINEERING, 2023, 77
  • [40] Artificial neural network model for performance evaluation of an integrated desiccant air conditioning system activated by solar energy
    Aly, Ayman A.
    Saleh, B.
    Bassuoni, M. M.
    Alsehli, M.
    Elfasakhany, A.
    Ahmed, Khaled I. E.
    AIMS ENERGY, 2019, 7 (03) : 395 - 412