Irradiation of cryogenic temperature sensors by gamma dose of 1 MGy

被引:6
|
作者
Filippov, Yu. P. [1 ]
Miklayev, V. M. [1 ]
Sukhanova, A. K. [1 ]
机构
[1] Joint Inst Nucl Res, Lab Part Phys, Dubna 141980, Russia
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2007年 / 78卷 / 04期
关键词
D O I
10.1063/1.2715927
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This article presents results of investigations of the cryogenic thermometers which can operate under high radiation environment. To clarify the temperature shifts due to gamma irradiation up to 1 MGy, the platinum (two types), carbon-glass, and TVO temperature sensors have been tested. Before the irradiation run, the selected sensors were calibrated and a series of experiments was carried out under irradiation of the sensors at 77.3 and 293 K when their readings were taken in situ. Afterwards, the postirradiation evolution (short and long time) of the sensors was measured at 4.2, 77.3, and 293 K. The results, depending on the type of the sensor, can be optimistic or pessimistic. Some comparisons with analogous data for fast neutron treatment have also been made. (c) 2007 American Institute of Physics.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] The influence of irradiation temperature on the thermoluminescence response of rock salt irradiated in the MGy range
    Dies, J
    de las Cuevas, C
    Tarrasa, F
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 487 - 492
  • [22] The impact of gamma irradiation on SiGeHBTs operating at cryogenic temperatures
    Cressler, JD
    Krithivasan, R
    Sutton, AK
    Seiler, JE
    Krieg, JF
    Clark, SD
    Joseph, AJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (06) : 1805 - 1810
  • [23] Thermal resistances of mounted cryogenic temperature sensors
    Holmes, DS
    Courts, SS
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 41, PTS A AND B, 1996, : 1699 - 1706
  • [24] A Review of Cryogenic Thermometry and Common Temperature Sensors
    Yeager, C. J.
    Courts, S. S.
    IEEE SENSORS JOURNAL, 2001, 1 (04) : 352 - 360
  • [25] Thermal Resistances of Mounted Cryogenic Temperature Sensors
    Holmes, D. S.
    Courts, S. S.
    Advances in Cryogenic Engineering, (41/B):
  • [26] Fiber Bragg grating cryogenic temperature sensors
    Gupta, S
    Mizunami, T
    Yamao, T
    Shimomura, T
    APPLIED OPTICS, 1996, 35 (25): : 5202 - 5205
  • [27] Effects of packaging on thermal resistance below 1 K for cryogenic temperature sensors
    Courts, SS
    Yeager, CJ
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 412 - 419
  • [28] Neutron irradiation tests of calibrated cryogenic sensors at low temperatures
    Junquera, T
    Amand, JF
    Thermeau, JP
    Casas-Cubillos, J
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 765 - 772
  • [29] Gamma irradiation of semitransparent amorphous silicon sensors
    Fernández, MG
    Ferrando, A
    Josa, MI
    Molinero, A
    Oller, JC
    Arce, P
    Calvo, E
    Figueroa, CF
    García, N
    Matorras, F
    Rodrigo, T
    Vila, I
    Virto, AL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 439 (01): : 111 - 116
  • [30] Gamma Irradiation of Magnetoresistive Sensors for Planetary Exploration
    Sanz, Ruy
    Fernandez, Ana B.
    Dominguez, Jose A.
    Martin, Boris
    Michelena, Marina D.
    SENSORS, 2012, 12 (04): : 4447 - 4465