Magnetic bead-based detection of autoimmune responses using protein microarrays

被引:8
|
作者
Gantelius, Jesper [2 ]
Hartmann, Michael [1 ,3 ]
Schwenk, Jochen M. [4 ]
Roeraade, Johan [3 ]
Andersson-Svahn, Helene [2 ]
Joos, Thomas O. [1 ]
机构
[1] Univ Tubingen, NMI Nat & Med Sci Inst, Reutlingen, Germany
[2] Royal Inst Technol, Sch Biotechnol, Div Nanobiotechnol, Stockholm, Sweden
[3] Royal Inst Technol, Sch Chem Sci & Engn, Dept Analyt Chem, Stockholm, Sweden
[4] Royal Inst Technol, Sch Biotechnol, Div Prote, Stockholm, Sweden
关键词
TECHNOLOGY; ASSAY;
D O I
10.1016/j.nbt.2009.07.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present study, a magnetic bead-based detection approach for protein microarrays is described as an alternative approach to the commonly used fluorescence-based detection system. Using the bead-based detection approach with applied magnetic force, it was possible to perform the detection step more rapidly as a result of the accelerated binding between the captured. analyte in the microspot and the detection antibody, which was coupled to the magnetic beads. The resulting strong opacity shift on the microspots could be recorded with an ordinary flatbed scanner. In the context of autoimmunity, a set of 24 serum samples was analyzed for the presence of antibodies against 12 autoantigens using standard fluorescence and magnetic bead-based detection methods. Dynamic range, sensitivity, and specificity were determined for both detection methods. We propose from our findings that the magnetic bead-based detection option provides a simplified and cost effective readout method for protein microarrays.
引用
收藏
页码:269 / 276
页数:8
相关论文
共 50 条
  • [41] A Magnetic Bead-Based Method for Concentrating DNA from Human Urine for Downstream Detection
    Bordelon, Hali
    Russ, Patricia K.
    Wright, David W.
    Haselton, Frederick R.
    PLOS ONE, 2013, 8 (07):
  • [42] Magnetic bead-based chemiluminescence detection of sequence-specific DNA by using catalytic nucleic acid labels
    Cao, ZJ
    Li, ZX
    Zhao, YJ
    Song, YM
    Lu, JZ
    ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) : 152 - 158
  • [43] Assessment of direct versus indirect magnetic bead-based T-cell isolation procedures followed by magnetic bead-based DNA isolation
    Rosenbaum, Anna
    Bleck, Ellen
    Schneider, Matthias
    Pongratz, Georg
    Vordenbaumen, Stefan
    LUPUS SCIENCE & MEDICINE, 2016, 3 (01):
  • [44] Magnetic bead-based chemiluminescence detection of sequence-specific DNA with HRP labelling
    Li, H.
    He, Z.
    LUMINESCENCE, 2008, 23 (02) : 80 - 80
  • [46] Bead-Based Hydrodynamic Simulations of Rigid Magnetic Micropropellers
    Codutti, Agnese
    Bachmann, Felix
    Faivre, Damien
    Klumpp, Stefan
    FRONTIERS IN ROBOTICS AND AI, 2018, 5
  • [47] Integrated microfluidic chip for cell culture and stimulation and magnetic bead-based biomarker detection
    Ruffert, Christine
    Ramadan, Qasem
    Ruegg, Matthieu
    Vergères, Guy
    Gijs, Martin A. M.
    Micro and Nanosystems, 2014, 6 (01) : 61 - 68
  • [48] A Novel Magnetic Bead-based Biosensor Using Flip Chip Bonding Techniques
    Bin Wang Xiang Chen Qinghui Jin Jianlong Zhao Yuansen Xu Shanghai Institute of Microsystem and Information TechnologyCASShanghai China
    稀有金属材料与工程, 2006, (S3) : 421 - 424
  • [49] Microelectrodes in bead-based sandwich immunoassay detection.
    Farrell, S
    Halsall, HB
    Heineman, WR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U124 - U124
  • [50] An integrated microfluidic biochemical detection system with magnetic bead-based sampling and analysis capabilities
    Choi, JW
    Oh, KW
    Thomas, JH
    Heineman, WR
    Halsall, HB
    Nevin, JH
    Helmicki, AJ
    Henderson, HT
    Ahn, CH
    14TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2001, : 447 - 450