Real-time standoff detection of nitrogen isotopes in ammonia plumes using a swept external cavity quantum cascade laser

被引:11
|
作者
Phillips, Mark C. [1 ]
Brumfield, Brian E. [1 ]
Harilal, Sivanandan S. [1 ]
机构
[1] Pacific Northwest Natl Lab, Richland, WA 99352 USA
关键词
ATMOSPHERIC AMMONIA; OPEN-PATH; ABSORPTION-SPECTROSCOPY; ISOTOPOLOGUES; SPECTROMETRY; WATER; BAND;
D O I
10.1364/OL.43.004065
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A swept-wavelength external cavity quantum cascade laser is used to measure time-resolved (NH3)-N-15 and (NH3)-N-14 concentrations and isotope ratios in a turbulent plume source located at 10 m standoff distance. Measurements show excellent agreement with expected values of isotope ratios for samples with natural and enriched (15) N abundance. Detection sensitivity of 150 ppb*m is demonstrated for a 50 ms measurement interval, improving to 10 ppb*rn with 10 s averaging, with isotopic precision as good as 0.8%. (C) 2018 Optical Society of America
引用
收藏
页码:4065 / 4068
页数:4
相关论文
共 50 条
  • [31] Atmospheric ammonia measurements in Houston, TX using an external-cavity quantum cascade laser-based sensor
    Gong, L.
    Lewicki, R.
    Griffin, R. J.
    Flynn, J. H.
    Lefer, B. L.
    Tittel, F. K.
    [J]. ATMOSPHERIC CHEMISTRY AND PHYSICS, 2011, 11 (18) : 9721 - 9733
  • [32] Hyperspectral microscopy of explosives particles using an external cavity quantum cascade laser
    Phillips, Mark C.
    Bernacki, Bruce E.
    [J]. OPTICAL ENGINEERING, 2013, 52 (06)
  • [33] Quantitative isotopic measurements of gas-phase alcohol mixtures using a broadly tunable swept external cavity quantum cascade laser
    Brumfield, B. E.
    Phillips, M. C.
    [J]. ANALYST, 2017, 142 (13) : 2354 - 2362
  • [34] Development of an external cavity quantum cascade laser spectrometer at 7.5 μm for gas detection
    D. Mammez
    R. Vallon
    B. Parvitte
    M-H. Mammez
    M. Carras
    V. Zéninari
    [J]. Applied Physics B, 2014, 116 : 951 - 958
  • [35] Development of an external cavity quantum cascade laser spectrometer at 7.5 μm for gas detection
    Mammez, D.
    Vallon, R.
    Parvitte, B.
    Mammez, M-H.
    Carras, M.
    Zeninari, V.
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 116 (04): : 951 - 958
  • [36] Ammonia detection by using quantum-cascade laser photoacoustic spectroscopy
    Filho, Milton B.
    da Silva, Marcelo G.
    Sthel, Marcelo S.
    Schramm, Delson U.
    Vargas, Helion
    Miklos, Andras
    Hess, Peter
    [J]. APPLIED OPTICS, 2006, 45 (20) : 4966 - 4971
  • [37] A novel honey authenticity detection system based on external cavity quantum cascade laser
    Liu, Yachao
    Gao, Yuan
    Jiao, Leizi
    Wu, Jianwei
    Dong, Daming
    [J]. LWT-FOOD SCIENCE AND TECHNOLOGY, 2023, 182
  • [38] Recent Advances and Applications of External Cavity-QCLs towards Hyperspectral Imaging for Standoff Detection and Real-Time Spectroscopic Sensing of Chemicals
    Ostendorf, Ralf
    Butschek, Lorenz
    Hugger, Stefan
    Fuchs, Frank
    Yang, Quankui
    Jarvis, Jan
    Schilling, Christian
    Rattunde, Marcel
    Merten, Andre
    Grahmann, Jan
    Boskovic, Dusan
    Tybussek, Thorsten
    Rieblinger, Klaus
    Wagner, Joachim
    [J]. PHOTONICS, 2016, 3 (02)
  • [39] Real-time modeling of quantum cascade laser operation using linear combinations of intrawell properties
    Cooney, A. T.
    Sarangan, A. M.
    [J]. JOURNAL OF COMPUTATIONAL ELECTRONICS, 2010, 9 (01) : 8 - 15
  • [40] Real-time modeling of quantum cascade laser operation using linear combinations of intrawell properties
    A. T. Cooney
    A. M. Sarangan
    [J]. Journal of Computational Electronics, 2010, 9 : 8 - 15