Statistical Analysis for Non Invasive Assessment of Blood Flow Volume in the High Pressure and Low Pressure Subjects Using IPG Technique and the Stroke Volume Estimation

被引:0
|
作者
Kumar, Ram M. [1 ]
Babu, Ganesh C. [2 ]
机构
[1] Sri Krishna Coll Engn & Technol, Dept Elect & Commun Engn, Coimbatore, Tamil Nadu, India
[2] Bannari Amman Inst Technol, Dept Elect & Commun Engn, Sathyamangalam, Tamil Nadu, India
来源
PROCEEDINGS OF THE 2019 INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING & COMMUNICATION ENGINEERING (ICACCE-2019) | 2019年
关键词
End Systolic Volume (ESD); End Diastolic Volume (EDV); Stroke Volume (SV); Impedance Plethysmography (IPG); CARDIAC-OUTPUT; IMPEDANCE CARDIOGRAPHY; NONINVASIVE MEASUREMENT; THERMODILUTION; BIOIMPEDANCE;
D O I
10.1109/icacce46606.2019.9079989
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
A systematic model is being developed individually for determining the blood flow volume using impedance plethysmographic technique. To make the validation for this measurement the stroke likewise estimated at the same time with the assistance of Echocardiogram. The analysis for validation is carried out for the low pressure and high pressure subjects as well as for the normal subjects. Basically the hardware setup for Impedance Plethysmographic signal conditioning circuitry has been developed based on the genesis. The maximum peak voltage amplitude is measured with the help of the IPG device and the blood flow volume is determined for the calculation in per minute basis. At the same time the stroke volume is additionally controlled by taking the distinction between end diastolic volume and end systolic volume. A direct relapse investigation is made between pinnacle voltage adequacy of impedance plethysmographic waveform and the stroke volume by utilizing straight bend fitting technique. Three different stages of high pressure and three different stages of low pressure is considered for the medical condition in this study and the regression analysis is done.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] THE VALUE OF AORTIC BLOOD-FLOW MEASUREMENTS USING DOPPLER TECHNIQUE FOR THE QUANTITATIVE ASSESSMENT OF CHANGES IN STROKE VOLUME
    ELKAYAM, U
    GARDIN, J
    BERKLEY, R
    HUGHES, C
    HENRY, WL
    CIRCULATION, 1981, 64 (04) : 256 - 256
  • [32] High Stroke Volume Variation Is an Independent Predictor for Decreased Blood Pressure During Hemodialysis
    Yoshihara, Fumiki
    Kishida, Masatsugu
    Ogawa, Koji
    Nishigaki, Takayuki
    Nakasaki, Hironori
    Ishizuka, Azusa
    Koezuka, Ryo
    Matsuo, Miki
    Hayashi, Teruyuki
    Nakamura, Satoko
    THERAPEUTIC APHERESIS AND DIALYSIS, 2017, 21 (02) : 166 - 172
  • [33] PRESSURE VOLUME LOOP ANALYSIS IN PATIENTS WITH SINGLE VENTRICLES: COMPARISON OF PRESSURE-VOLUME LOOP AND NON-INVASIVE MEASURES OF SYSTOLIC FUNCTION
    Chowdhury, Shahryar
    Butts, Ryan
    Buckley, Jason
    Hlavacek, Anthony
    Khambadkone, Sachin
    Hsia, Tain-Yen
    Baker, G. Hamilton
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E488 - E488
  • [34] Glomerular hyperfiltration, high renin, and low-extracellular volume in high blood pressure
    Harrap, SB
    Cumming, AD
    Davies, DL
    Foy, CJW
    Fraser, R
    Kamitani, A
    Connor, JM
    Lever, AF
    Watt, GCM
    HYPERTENSION, 2000, 35 (04) : 952 - 957
  • [35] Estimation of Stroke Volume Variance from Arterial Blood Pressure: Using a 1-D Convolutional Neural Network
    Kwon, Hye-Mee
    Seo, Woo-Young
    Kim, Jae-Man
    Shim, Woo-Hyun
    Kim, Sung-Hoon
    Hwang, Gyu-Sam
    SENSORS, 2021, 21 (15)
  • [36] Peak systolic velocity and flow volume increase with blood pressure in low resistance systems
    Creighton University Medical Center, 601 North 30th St., Omaha, NE 68132, United States
    J. ULTRASOUND MED., 3 (199-203):
  • [37] COMPARISON OF INTRACRANIAL-PRESSURE BETWEEN SPINA-BIFIDA PATIENTS AND NORMAL SUBJECTS USING A NON-INVASIVE PRESSURE ASSESSMENT TECHNIQUE
    MOSS, SM
    MARCHBANKS, RJ
    REID, A
    BURGE, D
    MARTIN, AM
    ZEITSCHRIFT FUR KINDERCHIRURGIE-SURGERY IN INFANCY AND CHILDHOOD, 1989, 44 : 29 - 31
  • [38] Non-invasive estimation of blood pressure using ultrasound contrast agents
    Andersen, Klaus Scheldrup
    Jensen, Jorgen Arendt
    INTERNATIONAL CONGRESS ON ULTRASONICS, PROCEEDINGS, 2010, 3 (01): : 245 - 253
  • [39] Non-invasive Estimation of Pressure Gradients in Pulsatile Flow using Ultrasound
    Olesen, Jacob Bjerring
    Hoyos, Carlos Armando Villagomez
    Traberg, Marie Sand
    Jensen, Jorgen Arendt
    2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2257 - 2260
  • [40] Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress
    Harms, MPM
    Wesseling, KH
    Pott, F
    Jenstrup, M
    von Goudoever, J
    Secher, NH
    van Lieshout, JJ
    CLINICAL SCIENCE, 1999, 97 (03) : 291 - 301