Design of slender shear connected masonry cavity walls

被引:0
|
作者
Wang, R
Elwi, AE [1 ]
Hatzinikolas, MA
机构
[1] Univ Alberta, Dept Civil Engn, Edmonton, AB T6G 2G7, Canada
[2] Canadian Masonry Res Inst, Edmonton, AB T5S 2H1, Canada
关键词
cavity walls; effective stiffness; masonry; masonry ties; moment magnifier; shear connectors; structural design; structures; walls;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent work the writers carried out extensive testing and numerical analysis investigation of slender cavity masonry walls constructed with vertically aligned shear connectors and subjected to eccentric vertical compressive loads. This type of masonry tie has been shown to provide increased stiffness and strength characteristics to the wall system. In this paper a multilinear regression analysis is carried out based on the data generated by that investigation. The effective stiffness of the shear connected cavity walls is evaluated. A design approach for these walls when subjected to eccentric compressive loads is proposed. This design approach makes use of the effective stiffness in the context of the moment magnifier method. It is then verified against the code requirements and available test data by the writers and others.
引用
收藏
页码:808 / 818
页数:11
相关论文
共 50 条
  • [21] Shear resistance of masonry walls and Eurocode 6: shear versus tensile strength of masonry
    Miha Tomaževič
    Materials and Structures, 2009, 42 : 889 - 907
  • [22] EVALUATION OF A SHEAR-FRICTION DESIGN MODEL FOR VERTICALLY REINFORCED MASONRY WALLS
    Petersen, R. B.
    Masia, M. J.
    PROCEEDINGS OF THE 9TH AUSTRALASIAN MASONRY CONFERENCE, 2011, : 533 - 542
  • [23] Shear resistance of masonry walls and Eurocode 6: shear versus tensile strength of masonry
    Tomazevic, Miha
    MATERIALS AND STRUCTURES, 2009, 42 (07) : 889 - 907
  • [24] Post-design strategy for shear walls of historic brick masonry buildings
    Karic, A.
    Sonnek, R.
    Deix, K.
    Kolbitsch, A.
    BAUINGENIEUR, 2023, 98 (1-2): : 18 - 27
  • [25] Solid masonry v/s cavity walls
    Aberdeen's Magazine of Masonry Construction, 1997, 10 (03):
  • [26] Tests on masonry shear walls, panel walls and upgrading methods
    1600, Publ by EERI, Oakland, CA, USA
  • [27] THE DESIGN OF PLAIN MASONRY WALLS
    OJINAGA, J
    TURKSTRA, CJ
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1980, 7 (02) : 233 - 242
  • [28] Shear modulus of masonry walls: a critical review
    Croce, Pietro
    Beconcini, Maria Luisa
    Formichi, Paolo
    Cioni, Paolo
    Landi, Filippo
    Mochi, Caterina
    De Lellis, Francesco
    Mariotti, Elisabetta
    Serra, Isabelle
    XIV INTERNATIONAL CONFERENCE ON BUILDING PATHOLOGY AND CONSTRUCTIONS REPAIR, 2018, 11 : 339 - 346
  • [29] HYSTERETIC BEHAVIOR OF REINFORCED MASONRY SHEAR WALLS
    MOTTA, F
    BRICK AND BLOCK MASONRY, VOLS 1-3, 1988, : 1140 - 1147
  • [30] EVALUATION OF SHEAR CAPACITY FOR BRICK MASONRY WALLS
    Partene, Eva
    Fekete-Nagy, Luminita
    Stoian, V.