Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes

被引:141
|
作者
Carpineto, P [1 ]
Ciancaglini, M [1 ]
Zuppardi, E [1 ]
Falconio, G [1 ]
Doronzo, E [1 ]
Mastropasqua, L [1 ]
机构
[1] Univ GD Annunzio Clin Hosp Colle Ara, Sect Ophthalmol, Dept Med & Aging Sci, I-66013 Chieti, Italy
关键词
D O I
10.1016/S0161-6420(02)01296-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate the reliability of nerve fiber layer (NFL) thickness measurements by optical coherence tomography (OCT) in normal and glaucomatous eyes. Design: Prospective, comparative, observational case series and instrument validation study. Participants: Twenty-four glaucomatous patients were compared with 24 gender- and age-matched normal subjects. Methods: Each individual underwent OCT measurements of NFL thickness. Five repetitions of a series of scans on five separate occasions within a 0.5-month period were performed. Each eye was scanned at three different nerve head programs (1.5 radius [R], R = 1.73 mm, 2.0 R). For each option (1.5 R, R = 1.73 mm, and 2.0 R) and region (superior, inferior, temporal, nasal, and overall mean), variance components and intraclass correlation coefficients were determined using repeated measures regression. In these models, NFL thickness, as measured by OCT, was assumed to have three variance components: intersubject, intervisit (within-subject between-dates), and intravisit (within-subject within-date). The intraclass correlation coefficient (intersubject variance/total variance) was used as a measure of reliability. Main Outcome Measures: Measurements of NFL thickness using OCT were performed. Results: Reliability values, as measured by intraclass correlation coefficients, resulted as follows: 1.5 R, 0.54/0.52 (normal/glaucoma); R = 1.73 mm, 0.50/0.50; 2.0 R, 0.49/0.50. Conclusions: Our results indicate that the recent commercially available OCT provides reliable NFL thickness measurements in both healthy and glaucomatous eyes with each circle radius tested. The greatest amount of variability can be attributed to intersubject differences. (C) 2003 by the American Academy of Ophthalmology.
引用
收藏
页码:190 / 195
页数:6
相关论文
共 50 条
  • [41] Changes of Neuroretinal Rim and Retinal Nerve Fiber Layer Thickness Assessed by Optical Coherence Tomography After Filtration Surgery in Glaucomatous Eyes
    Koenig, Susanna Friederike
    Hirneiss, Christoph Wolfgang
    [J]. CLINICAL OPHTHALMOLOGY, 2021, 15 : 2335 - 2344
  • [42] NERVE-FIBER LAYER THICKNESS IN GLAUCOMATOUS EYES
    FELDMAN, RM
    FELDMAN, ST
    GROSS, RL
    ORENGONANIA, S
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1510 - 1510
  • [43] Agreement between scanning laser polarimetry and optical coherence tomography measurements of the retinal nerve fiber layer thickness in glaucomatous patients
    Tavares, IM
    Sakai, VN
    Takata, TT
    Melo, LAS
    Prata, JA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [44] Retinal nerve fiber layer thickness measured by optical coherence tomography in non-glaucomatous Taiwanese
    Peng, Pai-Huei
    Lin, Huey-Shyan
    [J]. JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2008, 107 (08) : 627 - 634
  • [45] Quantitation of nerve fiber layer thickness loss over time in the glaucomatous monkey model using optical coherence tomography
    Schuman, JS
    PedutKloizman, T
    Pieroth, L
    Hertzmark, E
    Hee, MR
    Wilkins, JR
    Coker, JG
    Puliafito, CA
    Fujimoto, JG
    Swanson, EA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 5255 - 5255
  • [46] Retinal nerve fiber layer thickness evaluation using optical coherence tomography in eyes with optic disc hemorrhage
    Choi, Jin
    Park, Ki Ho
    Kim, Dong Myung
    Kim, Tae Woo
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (02) : 118 - 125
  • [47] Retinal nerve fiber layer thickness in normal children measured with optical coherence tomography
    Salchow, DJ
    Oleynikov, YS
    Chiang, MF
    Kennedy-Salchow, SE
    Langton, K
    Tsai, JC
    Al-Aswad, LA
    [J]. OPHTHALMOLOGY, 2006, 113 (05) : 786 - 791
  • [48] Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments
    Bourne, RRA
    Medeiros, FA
    Bowd, C
    Jahanbakhsh, K
    Zangwill, LM
    Weinreb, RN
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) : 1280 - 1285
  • [49] Effect of pupillary dilation on retinal nerve fiber layer thickness measurements using optical coherence tomography
    Zafar, S
    Gurses-Ozden, R
    Vessani, R
    Makornwattana, M
    Liebmann, JM
    Tello, C
    Ritch, R
    [J]. JOURNAL OF GLAUCOMA, 2004, 13 (01) : 34 - 37
  • [50] Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Wu, Huijuan
    de Boer, Johannes F.
    Chen, Teresa C.
    [J]. JOURNAL OF GLAUCOMA, 2011, 20 (08) : 470 - 476