Flow Injection Amperometric Detection and Off-line Sequential Extraction Column for Fractionation of Phosphorus in Sediment

被引:0
|
作者
Insain, Pimporn [1 ]
Jakmunee, Jaroon [2 ]
机构
[1] Chiang Mai Univ, Dept Chem, Fac Sci, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Ctr Excellence Innovat Chem, Fac Sci, Chiang Mai 50200, Thailand
来源
CHIANG MAI JOURNAL OF SCIENCE | 2017年 / 44卷 / 03期
关键词
flow injection amperometry; phosphorus; fractionation; sequential extraction; sediment; INORGANIC PHOSPHORUS; SOILS; FORMS; LAKE; RELEASE; SYSTEM; CHEMISTRY; RESERVOIR; WATERS; CHINA;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Flow injection amperometric system has been developed for determination of phosphorus. It is based on in-line formation of 12-molybdophosphate complex, which is further electrochemically reduced on a glassy carbon working electrode at a constant applied potential of 0.20 V vs. Ag/AgCl. An electrical current is directly proportional to phosphate concentration. Calibration graphs plotting between peak height and phosphate concentration were obtained in range of 0.1-1.0 and 1.0-10.0 mg L-1 P-PO4, with a detection limit of 0.03 mg L-1 P-PO4. The precision of 2.1, 2.6, 1.5, 1.2 and 1.0% (n=11, 0.1, 0.5, 1.0, 5.0 and 10.0 mg L-1 P-PO4, respectively) and sample throughput of 90 h(-1) were achieved. The method has lower interferences (i.e., from silicate, colored and colloidal substances, and the Schlieren's effect) than the commonly used spectrophotometric method. Although it may be interfered by cations, e.g., Fe3+ and Al3+, these ions could be eliminated by using Chelex 100 resin column. The proposed system was successfully applied to determine phosphorus that sequentially leached from sediments. An off-line leaching column was proposed for fractionation of phosphorus according to Hieltjes-Lijklema scheme (HLS), employing 1.0 M NH4 Cl, 0.1 M NaOH, and 0.5 M HCl as extractants, respectively. The results obtained from extraction by using the proposed column method and the batch shaking method were in good agreement (no significant difference at 95% confident level).
引用
收藏
页码:965 / 976
页数:12
相关论文
共 50 条
  • [21] Development of flow injection potentiometric methods for the off-line and on-line determination of fluoride to monitor the biodegradation of a monofluorophenol in two bioreactors
    Mesquita, Raquel B. R.
    Santos, Ines C.
    Pedrosa, Marta F. F.
    Duque, Anouk F.
    Castro, Paula M. L.
    Rangel, Antonio O. S. S.
    TALANTA, 2011, 84 (05) : 1291 - 1297
  • [22] Determination of Iodide, Iodate and Total Iodine in Natural Water Samples by HPLC with Amperometric and Spectrophotometric Detection, and Off-line UV Irradiation
    Takeda, Akira
    Tsukada, Hirofumi
    Takaku, Yuichi
    Satta, Naoya
    Baba, Mitsuhisa
    Shibata, Toshihiro
    Hasegawa, Hidenao
    Unno, Yusuke
    Hisamatsu, Shun'ichi
    ANALYTICAL SCIENCES, 2016, 32 (08) : 839 - 845
  • [23] Determination of iodide, iodate and total iodine in natural water samples by HPLC with amperometric and spectrophotometric detection, and off-line UV irradiation
    Takeda A.
    Tsukada H.
    Takaku Y.
    Satta N.
    Baba M.
    Shibata T.
    Hasegawa H.
    Unno Y.
    Hisamatsu S.
    Analytical Sciences, 2016, 32 (8) : 839 - 845
  • [24] Flow-injection determination of total organic fluorine with off-line defluorination reaction on a solid sorbent bed
    Musijowski, Jacek
    Trojanowicz, Marek
    Szostek, Bogdan
    da Costa Lima, Jose Luis Fontes
    Lapa, Rui
    Yamashita, Hiroki
    Takayanagi, Toshio
    Motomizu, Shoji
    ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) : 147 - 154
  • [25] Continuous-flow fractionation of selenium in contaminated sediment and soil samples using rotating coiled column and microcolumn extraction
    Savonina, Elena Yu.
    Fedotov, Petr S.
    Wennrich, Rainer
    TALANTA, 2012, 88 : 369 - 374
  • [26] Method of analysis of a selected group of pyrethroids in soil samples using off-line flow-through extraction and on-column direct large-volume injection in reversed phase high performance liquid chromatography
    Chalanyova, Maria
    Paulechova, Martina
    Hutta, Milan
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (14) : 2149 - 2157
  • [27] OFF-LINE AND ONLINE ASSAY OF MEMBRANE-PROTEIN WITH ORTHO-PHTHALDIALDEHYDE BY FLOW-INJECTION WITH POSTCOLUMN REACTION
    MOZERSKY, SM
    ANALYTICA CHIMICA ACTA, 1990, 231 (02) : 249 - 257
  • [28] Separation of polystyrene nanoparticles with different coatings using two-dimensional off-line coupling of asymmetrical flow field flow fractionation and capillary electrophoresis
    You, Zengchao
    Jakubowski, Norbert
    Panne, Ulrich
    Weidner, Steffen M.
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1593 : 119 - 126
  • [29] Sequential injection system incorporatin a micro-extraction column for automatic fractionation of metal ions in solid samples comparison of the extraction profiles when employing uni-, bi-, and multi-bi-directional flow plus stopped-flow sequential extraction modes
    Chomchoei, R
    Miró, M
    Hansen, EH
    Shiowatana, J
    ANALYTICA CHIMICA ACTA, 2005, 536 (1-2) : 183 - 190
  • [30] Effect of decreasing column inner diameter and use of off-line two-dimensional chromatography on metabolite detection in complex mixtures
    Edwards, James L.
    Edwards, Rachel L.
    Reid, Kendra R.
    Kennedy, Robert T.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1172 (02) : 127 - 134