Comparing Deep Sclerectomy With Collagen Implant to the New Method of Very Deep Sclerectomy With Collagen Implant A Single-masked Randomized Controlled Trial

被引:15
|
作者
Mansouri, Kaweh [1 ]
Tran, Hoai Viet [1 ]
Ravinet, Emilie [1 ]
Mermoud, Andre [1 ]
机构
[1] Univ Lausanne, Jules Gonin Eye Hosp, Dept Ophthalmol, CH-1004 Lausanne, Switzerland
关键词
deep sclerectomy; collagen implant; uveoscleral outflow; randomized controlled trial; ULTRASOUND BIOMICROSCOPY; NONPENETRATING TRABECULECTOMY; EYES;
D O I
10.1097/IJG.0b013e3181a2fa46
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To prospectively study the intraocular pressure (IOP) lowering effect and safety of the new method of very deep sclerectomy with collagen implant (VDSCI) compared with standard deep sclerectomy with collagen implant (DSCI). Methods: The trial involved 50 eyes of 48 patients with medically uncontrolled primary and secondary open-angle glaucoma, randomized to undergo either VDSCI procedure (25 eyes) or DSCI procedure (25 eyes). Follow-up examinations were performed before surgery and after Surgery at day 1, at week 1, at months 1, 2, 3, 6, 9, 12, 18, and 24 months. Ultrasound biornicroscopy was performed at 3 and 12 months. Results: Mean follow-up period was 18.6 +/- 5.9 (VDSCI) and 18.9 +/- 3.6 (DSCI) months (P = NS). Mean preoperative IOP was 22.4 +/- 7.4 mm Hg for VDSCI and 20.4 +/- 4.4 mm Hg for DSCI eves (P = NS). Mean postoperative IOP was 3.9 +/- 2.3 (VDSCI) and 6.3 +/- 4.3 (DSCI) (P < 0.05) at day 1, and 12.2 +/- 3.9 (VDSCI) and 13.3 +/- 3.4 (DSCI) (P = NS) at month 24. At the last visit, the complete success rate (defined as an IOP of <= 18 mm Hg and a percentage drop of at least 20%, achieved without medication) was 57% in VDSCI and 62% in DSCI eves (P = NS) ultrasound biomicroscopy at 12 months showed a mean volume of the subconjunctival filtering bleb of 3.9 +/- 4.2 mm(3) (VDSCI) and 6.8 +/- 7.5 mm(3) (DSCI) (P = 0.426) and 5.2 +/- 3.6 mm(3) (VDSCI) and 5.4 +/- 2.9 mm(3) (DSCI) (P = 0.902) for the intrascleral space. Conclusions: Very deep sclerectomy seems to provide stable and good control of IOP at 2 years of follow-up with few postoperative complications similar to standard deep sclerectomy with the collagen implant.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [21] Evolution of collagen implant after deep sclerectomy - creation of an animal model
    Delarive, T
    Mermoud, A
    Uffer, S
    Rossler, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S269 - S269
  • [22] Nd-Yag goniopuncture after deep sclerectomy with collagen implant
    Mermoud, A
    Faggioni, R
    Sickenberg, M
    Schnyder, CC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1167 - 1167
  • [23] An ultrasound biomicroscopic study of eyes after deep sclerectomy with collagen implant
    Chiou, AGY
    Mermoud, A
    Underdahl, JP
    Schnyder, CC
    OPHTHALMOLOGY, 1998, 105 (04) : 746 - 750
  • [24] In vivo study comparing an X-shaped polymethylmethacrylate and a cylindrical collagen implant for deep sclerectomy
    Codreanu, Andrea
    Tran, Hoai V.
    Wiaux, Christophe
    Mansouri, Kaweh
    Roy, Sylvain
    Mermoud, Andre
    Schnyder, Corinne
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (02): : 135 - 141
  • [25] Changes in anterior ocular structures and macula following deep sclerectomy with collagen implant
    Suominen, Sakari M. A.
    Harju, Mika P.
    Hautamaki, Asta M. E.
    Vesti, Eija T.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (01) : 47 - 51
  • [26] Comparison of deep sclerectomy with collagen implant and trabeculectomy in open-angle glaucoma
    Mermoud, A
    Schnyder, CC
    Sickenberg, M
    Chiou, AGY
    Hédiguer, SEA
    Faggioni, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (03): : 323 - 331
  • [27] Long-term Results of Deep Sclerectomy With Collagen Implant in Exfoliative Glaucoma
    Mendrinos, Efstratios
    Mansouri, Kaweh
    Mermoud, Andre
    Shaarawy, Tarek
    JOURNAL OF GLAUCOMA, 2009, 18 (05) : 361 - 367
  • [28] Ten Years Follow-up After Deep Sclerectomy With Collagen Implant
    Bissig, Alexandre
    Rivier, Delphine
    Zaninetti, Marc
    Shaarawy, Tarek
    Mermoud, Andre
    Roy, Sylvain
    JOURNAL OF GLAUCOMA, 2008, 17 (08) : 680 - 686
  • [29] Cross-shaped PMMA implant versus collagen cylindrical implant in deep sclerectomy in an animal model
    Tran, AAC
    Wiaux, C
    Roy, S
    Mermoud, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U317 - U317
  • [30] Iris synechia after laser goniopuncture in a patient having deep sclerectomy with a collagen implant
    Kim, CY
    Hong, YJ
    Seong, GJ
    Koh, HJ
    Kim, SS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 900 - 902