Intraoperative laparoscopic detection of sentinel lymph nodes with indocyanine green and superparamagnetic iron oxide in a swine gallbladder cancer model

被引:10
|
作者
Mihara, Kisyo [1 ,2 ]
Matsuda, Sachiko [2 ]
Nakamura, Yuki [2 ]
Aiura, Koichi [1 ]
Kuwahata, Akihiro [3 ]
Chikaki, Shinichi [3 ]
Sekino, Masaki [3 ]
Kusakabe, Moriaki [4 ,5 ]
Suzuki, Shunichi [6 ]
Fuchimoto, Daiichiro [6 ]
Onishi, Akira [7 ]
Kuramoto, Junko [8 ]
Kameyama, Kaori [9 ]
Itano, Osamu [10 ]
Yagi, Hiroshi [2 ]
Abe, Yuta [2 ]
Kitago, Minoru [2 ]
Shinoda, Masahiro [2 ]
Kitagawa, Yuko [2 ]
Xu, Bing
机构
[1] Kawasaki Municipal Kawasaki Hosp, Dept Surg, Kawasaki Ku, Kawasaki, Kanagawa, Japan
[2] Keio Univ, Dept Surg, Sch Med, Shinjuku Ku, Tokyo, Japan
[3] Univ Tokyo, Grad Sch Engn, Bunkyo Ku, Tokyo, Japan
[4] Univ Tokyo, Res Ctr Food Safety, Grad Sch Agr & Life Sci, Bunkyo Ku, Tokyo, Japan
[5] Matrix Cell Res Inst Inc, Ushi Ku, Ibaraki, Japan
[6] Natl Agr & Food Res Org NARO, Div Anim Sci, Inst Agrobiol Sci, Tsukuba, Ibaraki, Japan
[7] Nihon Univ, Coll Bioresource Sci, Dept Anim Sci & Resources, Lab Anim Reprod, Fujisawa, Kanagawa, Japan
[8] Keio Univ, Dept Pathol, Sch Med, Shinjuku Ku, Tokyo, Japan
[9] Keio Univ Hosp, Dept Diagnost Pathol, Shinjuku Ku, Tokyo, Japan
[10] Int Univ Hlth & Welf, Dept Gastrointestinal Surg, Chiba, Japan
来源
PLOS ONE | 2021年 / 16卷 / 03期
关键词
D O I
10.1371/journal.pone.0248531
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Mapping of sentinel lymph nodes (SLNs) can enable less invasive surgery. However, mapping is challenging for cancers of difficult-to-access visceral organs, such as the gallbladder, because the standard method using radioisotopes (RIs) requires preoperative tracer injection. Indocyanine green (ICG) and superparamagnetic iron oxide (SPIO) have also been used as alternative tracers. In this study, we modified a previously reported magnetic probe for laparoscopic use and evaluated the feasibility of detecting SLNs of the gallbladder using a laparoscopic dual tracer method by injecting ICG and SPIO into five swine and one cancer-bearing swine. The laparoscopic probe identified SPIO nanoparticles in the nodes of 4/5 swine in situ, the magnetic field counts were 2.5-15.9 mu T, and fluorescence was detected in SLNs in all five swine. ICG showed a visual lymph flow map, and SPIO more accurately identified each SLN with a measurable magnetic field quite similar to the RI. We then developed an advanced gallbladder cancer model with lymph node metastasis using recombination activating gene 2-knockout swine. We identified an SLN in the laparoscopic investigation, and the magnetic field count was 3.5 mu T. The SLN was histologically determined to be one of the two metastatic lymph nodes. In conclusion, detecting the SLNs of gallbladder cancer in situ using a dual tracer laparoscopic technique with ICG and SPIO was feasible in a swine model.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Detection of Sentinel Nodes in Gastric Cancer by Indocyanine Green Fluorescence Imaging
    Fujita, Toshihiro
    Seshimo, Akiyoshi
    Kameoka, Shingo
    HEPATO-GASTROENTEROLOGY, 2012, 59 (119) : 2213 - 2216
  • [22] Superparamagnetic iron oxide as a tracer for sentinel lymph node detection in uterine cancer: a pilot study
    Murakami, Kosuke
    Kotani, Yasushi
    Suzuki, Ayako
    Takaya, Hisamitsu
    Nakai, Hidekatsu
    Matsuki, Mitsuru
    Sato, Takao
    Mandai, Masaki
    Matsumura, Noriomi
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [23] Superparamagnetic iron oxide as a tracer for sentinel lymph node detection in uterine cancer: a pilot study
    Kosuke Murakami
    Yasushi Kotani
    Ayako Suzuki
    Hisamitsu Takaya
    Hidekatsu Nakai
    Mitsuru Matsuki
    Takao Sato
    Masaki Mandai
    Noriomi Matsumura
    Scientific Reports, 10
  • [24] Indocyanine green sentinel lymph node mapping and detection in endometrial cancer
    Lau, Julio
    Estrada, Erick Estuardo
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2020, 30 (09) : 1460 - 1461
  • [25] Indocyanine green and infrared fluorescence in detection of sentinel lymph nodes in endometrial and cervical cancer staging - a systematic review
    Rocha, Anabela
    Maria Dominguez, Ana
    Lecuru, Fabrice
    Bourdel, Nicolas
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2016, 206 : 213 - 219
  • [26] Use of indocyanine green for detecting sentinel lymph nodes in breast cancer: letter to the editor
    Hidar, Samir
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2017, 15
  • [27] Indocyanine green can stand alone in detecting sentinel lymph nodes in cervical cancer
    Ulain, Qurat
    Han, Lu
    Wu, Qian
    Zhao, Lanbo
    Wang, Qi
    Tuo, Xiaoqian
    Wang, Yiran
    Wang, Qing
    Ma, Sijia
    Sun, Chao
    Song, Qing
    Li, Qiling
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (12) : 4885 - 4897
  • [28] Use of indocyanine green for detecting sentinel lymph nodes in breast cancer: letter to the editor
    Samir Hidar
    World Journal of Surgical Oncology, 15
  • [29] Utilization of Indocyanine Green to Aid in Identifying Sentinel Lymph Nodes in Merkel Cell Cancer
    Knackstedt, Rebecca W.
    Knackstedt, Thomas
    Gastman, Brian
    JOURNAL OF SURGICAL RESEARCH, 2018, 232 : 365 - 368
  • [30] Increased detection of sentinel nodes in breast cancer patients with the use of superparamagnetic iron oxide trtteer.
    Rubio, Isabel T.
    Diaz-Botero, Sebastian
    Esgueva, Antonio J.
    Espinosa-Bravo, Martin