Intraoperative laparoscopic detection of sentinel lymph nodes with indocyanine green and superparamagnetic iron oxide in a swine gallbladder cancer model

被引:10
|
作者
Mihara, Kisyo [1 ,2 ]
Matsuda, Sachiko [2 ]
Nakamura, Yuki [2 ]
Aiura, Koichi [1 ]
Kuwahata, Akihiro [3 ]
Chikaki, Shinichi [3 ]
Sekino, Masaki [3 ]
Kusakabe, Moriaki [4 ,5 ]
Suzuki, Shunichi [6 ]
Fuchimoto, Daiichiro [6 ]
Onishi, Akira [7 ]
Kuramoto, Junko [8 ]
Kameyama, Kaori [9 ]
Itano, Osamu [10 ]
Yagi, Hiroshi [2 ]
Abe, Yuta [2 ]
Kitago, Minoru [2 ]
Shinoda, Masahiro [2 ]
Kitagawa, Yuko [2 ]
Xu, Bing
机构
[1] Kawasaki Municipal Kawasaki Hosp, Dept Surg, Kawasaki Ku, Kawasaki, Kanagawa, Japan
[2] Keio Univ, Dept Surg, Sch Med, Shinjuku Ku, Tokyo, Japan
[3] Univ Tokyo, Grad Sch Engn, Bunkyo Ku, Tokyo, Japan
[4] Univ Tokyo, Res Ctr Food Safety, Grad Sch Agr & Life Sci, Bunkyo Ku, Tokyo, Japan
[5] Matrix Cell Res Inst Inc, Ushi Ku, Ibaraki, Japan
[6] Natl Agr & Food Res Org NARO, Div Anim Sci, Inst Agrobiol Sci, Tsukuba, Ibaraki, Japan
[7] Nihon Univ, Coll Bioresource Sci, Dept Anim Sci & Resources, Lab Anim Reprod, Fujisawa, Kanagawa, Japan
[8] Keio Univ, Dept Pathol, Sch Med, Shinjuku Ku, Tokyo, Japan
[9] Keio Univ Hosp, Dept Diagnost Pathol, Shinjuku Ku, Tokyo, Japan
[10] Int Univ Hlth & Welf, Dept Gastrointestinal Surg, Chiba, Japan
来源
PLOS ONE | 2021年 / 16卷 / 03期
关键词
D O I
10.1371/journal.pone.0248531
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Mapping of sentinel lymph nodes (SLNs) can enable less invasive surgery. However, mapping is challenging for cancers of difficult-to-access visceral organs, such as the gallbladder, because the standard method using radioisotopes (RIs) requires preoperative tracer injection. Indocyanine green (ICG) and superparamagnetic iron oxide (SPIO) have also been used as alternative tracers. In this study, we modified a previously reported magnetic probe for laparoscopic use and evaluated the feasibility of detecting SLNs of the gallbladder using a laparoscopic dual tracer method by injecting ICG and SPIO into five swine and one cancer-bearing swine. The laparoscopic probe identified SPIO nanoparticles in the nodes of 4/5 swine in situ, the magnetic field counts were 2.5-15.9 mu T, and fluorescence was detected in SLNs in all five swine. ICG showed a visual lymph flow map, and SPIO more accurately identified each SLN with a measurable magnetic field quite similar to the RI. We then developed an advanced gallbladder cancer model with lymph node metastasis using recombination activating gene 2-knockout swine. We identified an SLN in the laparoscopic investigation, and the magnetic field count was 3.5 mu T. The SLN was histologically determined to be one of the two metastatic lymph nodes. In conclusion, detecting the SLNs of gallbladder cancer in situ using a dual tracer laparoscopic technique with ICG and SPIO was feasible in a swine model.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] INTRAOPERATIVE FLUORESCENCE IMAGING WITH INDOCYANINE GREEN FOR SENTINEL LYMPH NODES FOR PROSTATE CANCER DURING LAPAROSCOPIC RADICAL PROSTATECTOMY
    Miki, Jun
    Yanagisawa, Takafumi
    Urabe, Fumihiko
    Yasue, Keiji
    Igarashi, Taro
    Shimada, Hayato
    Kimura, Takahiro
    Takahashi, Hiroyuki
    Kishimoto, Kouichi
    Egawa, Shin
    JOURNAL OF UROLOGY, 2016, 195 (04): : E1037 - E1037
  • [2] Sentinel lymph nodes detection using indocyanine green in patients with lung cancer
    Matsuoka, Hisashi
    Kondo, Kazuya
    Takizawa, Hiromitsu
    Uyama, Koh
    Hiroaki, Toba
    Koichiro, Kenzaki
    Sakiyama, Shozi
    Tangoku, Akira
    JOURNAL OF THORACIC ONCOLOGY, 2009, 4 (09) : S562 - S563
  • [3] Indocyanine Green for intraoperative Visualization and Detection of Sentinel Lymph Nodes in Patients with cutaneous malignant Melanoma
    Stoffels, I
    von der Stueck, H.
    Boy, C.
    Poeppel, T.
    Schadendorf, D.
    Klode, J.
    JOURNAL DER DEUTSCHEN DERMATOLOGISCHEN GESELLSCHAFT, 2013, 11 : 93 - 93
  • [4] Use of indocyanine green (ICG) in detection of axillary sentinel lymph nodes for breast cancer
    Nikolaou, C.
    BREAST, 2021, 56 : S77 - S77
  • [5] Superparamagnetic iron oxide (SPIO) for sentinel lymph node detection in vulvar cancer
    Del Valle, David
    Ruiz, Ruben
    Lekuona, Arantxa
    Cobas, Paloma
    Jaunarena, Ibon
    Gorostidi, Mikel
    Cespedes, Juan
    GYNECOLOGIC ONCOLOGY, 2024, 187 : 145 - 150
  • [6] Use of Indocyanine Green in Detection of Breast Axillary Sentinel Lymph Nodes
    Farnand, Alex W.
    Bhakta, Priya S.
    Afrasiabi, Mohammad R.
    Osipova, Maria
    Connolly, Mark M.
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2018, 227 (04) : S38 - S39
  • [7] Indocyanine green detects sentinel lymph nodes in early breast cancer
    Liu, Jun
    Huang, Linping
    Wang, Ning
    Chen, Ping
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2017, 45 (02) : 514 - 524
  • [8] Laparoscopic Indocyanine Green-Guided Sentinel Lymph Node Biopsy for Gallbladder Neoplasms
    Branes, Alejandro
    Acher, Alexandra
    Karanicolas, Paul
    ANNALS OF SURGICAL ONCOLOGY, 2024, 31 (10) : 6566 - 6566
  • [9] Carbon coated superparamagnetic iron oxide nanoparticles for sentinel lymph nodes mapping
    Wang, Yi-Xiang J.
    Wang, Da-Wei
    Zhu, Xiao-Ming
    Zhao, Feng
    Leung, Ken C. F.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2012, 2 (01) : 53 - 56
  • [10] Laparoscopic Indocyanine Green Sentinel Lymph Node Mapping in Endometrial Cancer
    Andrea Papadia
    Sara Imboden
    Franziska Siegenthaler
    Maria Luisa Gasparri
    Stefan Mohr
    Susanne Lanz
    Michael D. Mueller
    Annals of Surgical Oncology, 2016, 23 : 2206 - 2211