Real-time x-ray imaging with flat panels

被引:2
|
作者
Gilblom, D [1 ]
Colbeth, R [1 ]
Batts, M [1 ]
Meyer, B [1 ]
机构
[1] Varian Associates Inc, Palo Alto, CA 94303 USA
关键词
amorphous silicon; large-area imaging; x-ray; imager; flat panel; radiography;
D O I
10.1117/12.302556
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To provide real-time x-ray imaging, industry relies almost entirely on the combination of the x-ray image intensifier and the high-performance television camera. Although these devices have been pushed to remarkable degrees of performance, they remain complex electro-optical assemblies with significant built-in errors, instabilities and degradation mechanisms. We describe a replacement for these systems utilizing as a sensor a large array of amorphous silicon photodiodes and thin-film switching transistors. Specifically, the equipment described is a replacement for a 9-inch dual-mode x-ray image intensifier with a high-performance 2000-line digital tv camera capable of operating in both real-time video radioscopic and highperformance radiographic modes. The sensor-panel imager consists of three units: 1) a sensor assembly including a 1536x1920 pixel sensor, an x-ray scintillator and all electronics necessary to drive the sensor panel, collect the readout charge, convert the signal to 12-bit digital data and format the data into a serial data stream for transmission, 2) a controller which receives configuration and timing commands from the world, an image processor which corrects the pixel data for variations in dark level and sensitivity and interpolates dead pixels all in real time and provides digital and analog video data and a set of system interface signals out, and 3) a power supply module. In the radioscopic mode, this imager produces x-ray images at 30 frames per second with a resolution of just under 2 lp/mm. In the radiographic mode, five frames per second may be produced with nearly 4 lp/mm resolution. Doses from 1 mu R to 10mR per frame can be accommodated. Unlike x-ray image intensifiers, this system has no geometric distortion or performance rolloff at the edges, requires no high voltage and has no susceptibility to external magnetic fields. Unlike CCD x-ray sensors, this sensor tolerates accumulated x-ray exposures at the megarad level. Additional work is underway to develop sensors with larger area and higher resolution. Current status on these extensions will be reported. Others have reported on the development of amorphous silicon sensors suitable for replacement of photographic film in radiography. The present work extends this to real-time applications thereby promising the availability of the digital flat-panel technology as a universal x-ray imaging medium.
引用
收藏
页码:213 / 223
页数:11
相关论文
共 50 条
  • [41] High-throughput data acquisition and processing for real-time X-ray imaging
    Vogelgesang, Matthias
    Rota, Lorenzo
    Perez, Luis Eduardo Ardila
    Caselle, Michele
    Chilingaryan, Suren
    Kopmann, Andreas
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [42] Configurable real-time motion estimation for medical imaging: application to X-ray and ultrasound
    Abramov N.
    Fradkin M.
    Rouet L.
    Wischmann H.-A.
    Journal of Real-Time Image Processing, 2017, 13 (1) : 147 - 160
  • [43] Spatiotemporal Evaluation of Bubble Characteristics in Sodium Using Real-Time X-Ray Imaging
    Acharya, Avinash Kumar
    Rao, E. Hemanth
    Menaka, M.
    Das, Sanjay Kumar
    Ponraju, D.
    Venkatraman, B.
    NUCLEAR TECHNOLOGY, 2023, 209 (09) : 1351 - 1364
  • [44] The Application of X-ray Digital Real-time Imaging Technology in GIS Defect Diagnosis
    Cai, Xiaolan
    Wang, Dada
    Yu, Hong
    Zhao, Xianping
    Zhang, Wei
    PEEA 2011, 2011, 23
  • [45] Flat X-ray image intensifier system for real time fluoroscopy
    Onihashi, H
    Aida, H
    Nou, K
    Noji, T
    Murakoshi, Y
    Ito, K
    Saito, K
    Koma, J
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 509 - 515
  • [46] Progress report on the performance of real time selenium flat panel detectors for direct X-ray Imaging
    Tousignant, O
    Choquette, M
    Demers, Y
    Laperrière, L
    Leboeuf, J
    Honda, M
    Nishiki, M
    Takahashi, A
    Tsukamoto, A
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 503 - 510
  • [47] A real-time flat-panel X-ray pixel imaging system for low-dose medical diagnostics and craniofacial applications
    Chapuy, S
    Dimcovski, D
    Dimcovski, Z
    Grigoriev, E
    Grob, E
    Ligier, Y
    Pachoud, M
    Riondel, F
    Rüfenacht, D
    Sayegh, C
    Terrier, F
    Valley, JF
    Verdun, FR
    JOURNAL OF CRANIOFACIAL SURGERY, 2000, 11 (01) : 10 - 16
  • [48] A CdTe real time X-ray imaging sensor and system
    Spartiotis, K
    Havulinna, J
    Leppänen, A
    Pantsar, T
    Puhakka, K
    Pyyhtiä, J
    Schulman, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (03): : 478 - 486
  • [49] Real-time measurement of alveolar size and population using phase contrast x-ray imaging
    Leong, Andrew F. T.
    Buckley, Genevieve A.
    Paganin, David M.
    Hooper, Stuart B.
    Wallace, Megan J.
    Kitchen, Marcus J.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (11): : 4024 - 4038
  • [50] Real-time diagnostic imaging with a novel X-ray detector with multiple screen - CCD sensors
    Slump, CH
    van Dijk, PW
    Laanstra, GJ
    Kuipers, H
    Boer, MA
    Nijmeijer, AGJ
    Kemner, R
    Meulenbrugge, HJ
    Snoeren, RM
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 418 - 429