Comparison of Myocardial Perfusion Estimates From Dynamic Contrast-Enhanced Magnetic Resonance Imaging With Four Quantitative Analysis Methods

被引:61
|
作者
Pack, Nathan A. [1 ,2 ]
DiBella, Edward V. R. [1 ,2 ]
机构
[1] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[2] Univ Utah, Dept Radiol, UCAIR, Salt Lake City, UT 84132 USA
关键词
myocardial perfusion; DCE-MRI; kinetic modeling; quantitative; perfusion reserve; POSITRON-EMISSION-TOMOGRAPHY; GADOBENATE DIMEGLUMINE MULTIHANCE; MODEL-INDEPENDENT DECONVOLUTION; 1ST-PASS MR PERFUSION; MEAN TRANSIT-TIME; BLOOD-FLOW; DISTRIBUTION VOLUME; HEART PERFUSION; HEALTHY HUMANS; SINGLE-BOLUS;
D O I
10.1002/mrm.22282
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dynamic contrast-enhanced MRI has been used to quantify myocardial perfusion in recent years. Published results have varied widely, possibly depending on the method used to analyze the dynamic perfusion data. Here, four quantitative analysis methods (two-compartment modeling, Fermi function modeling, model-independent analysis, and Patlak plot analysis) were implemented and compared for quantifying myocardial perfusion. Dynamic contrast-enhanced MRI data were acquired in 20 human subjects at rest with low-dose (0.019 +/- 0.005 mmol/kg) bolus injections of gadolinium. Fourteen of these subjects were also imaged at adenosine stress (0.021 +/- 0.005 mmol/kg). Aggregate rest perfusion estimates were not significantly different between all four analysis methods. At stress, perfusion estimates were not significantly different between two-compartment modeling, model-independent analysis, and Patlak plot analysis. Stress estimates from the Fermi model were significantly higher (similar to 20%) than the other three methods. Myocardial perfusion reserve values were not significantly different between all four methods. Model-independent analysis resulted in the lowest model curve-fit errors. When more than just the first pass of data was analyzed, perfusion estimates from two-compartment modeling and model-independent analysis did not change significantly, unlike results from Fermi function modeling. Magn Reson Med 64:125-137, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:125 / 137
页数:13
相关论文
共 50 条
  • [31] Dynamic Contrast-Enhanced Magnetic Resonance Imaging for the Evaluation of Perfusion Heterogeneity in Idiopathic Pulmonary Fibrosis
    Weatherley, N.
    Marshall, H.
    Hughes, P.
    Austin, M.
    Smith, L.
    Renshaw, S. A.
    Bianchi, S.
    Wild, J. M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197
  • [32] Establishment of a Swine Model for Validation of Perfusion Measurement by Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Sauerbrey, Anika
    Hindel, Stefan
    Maass, Marc
    Krueger, Christine
    Wissmann, Andreas
    Kramer, Martin
    Nafz, Benno
    Luedemann, Lutz
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [33] Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Quantitative Lung Perfusion Imaging Using the Dual-Bolus Approach Comparison of 3 Contrast Agents and Recommendation of Feasible Doses
    Veldhoen, Simon
    Oechsner, Markus
    Fischer, Andre
    Weng, Andreas Max
    Kunz, Andreas Steven
    Bley, Thorsten Alexander
    Koestler, Herbert
    Ritter, Christian Oliver
    INVESTIGATIVE RADIOLOGY, 2016, 51 (03) : 186 - 193
  • [34] Functional tumor imaging with dynamic contrast-enhanced magnetic resonance imaging
    Choyke, PL
    Dwyer, AJ
    Knopp, MV
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (05) : 509 - 520
  • [35] Statistical analysis of pharmacokinetic models in dynamic contrast-enhanced magnetic resonance imaging
    Schmid, VJ
    Whitcher, BJ
    Yang, GZ
    Taylor, NJ
    Padhani, AR
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 886 - 893
  • [36] Contrast-enhanced dynamic magnetic resonance imaging of the rat kidney
    Fransen, R
    Muller, HJ
    Boer, WH
    Nicolay, K
    Koomans, HA
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (03): : 424 - 430
  • [37] Dynamic Contrast-enhanced Magnetic Resonance Imaging: Applications in Oncology
    Teo, Q. Q.
    Thng, C. H.
    Koh, T. S.
    Ng, Q. S. p
    CLINICAL ONCOLOGY, 2014, 26 (10) : E9 - E20
  • [38] Vascularity and Dynamic Contrast-Enhanced Breast Magnetic Resonance Imaging
    Frankhouser, David E.
    Dietze, Eric
    Mahabal, Ashish
    Seewaldt, Victoria L.
    FRONTIERS IN RADIOLOGY, 2021, 1
  • [39] Dynamic contrast-enhanced magnetic resonance imaging of the sarcopenic muscle
    Nicolato E.
    Farace P.
    Asperio R.M.
    Marzola P.
    Lunati E.
    Sbarbati A.
    Osculati F.
    BMC Medical Imaging, 2 (1)
  • [40] Information Criteria for Dynamic Contrast-Enhanced Magnetic Resonance Imaging
    Shinohara, Russell T.
    Crainiceanu, Ciprian S.
    Caffo, Brian S.
    Reich, Daniel S.
    2013 3RD INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION IN NEUROIMAGING (PRNI 2013), 2013, : 37 - 41