Design of a conduction-cooled 9.4T REBCO magnet for whole-body MRI systems

被引:47
|
作者
Miyazaki, Hiroshi [1 ]
Iwai, Sadanori [1 ]
Otani, Yasumi [1 ]
Takahashi, Masahiko [1 ]
Tosaka, Taizo [1 ]
Tasaki, Kenji [1 ]
Nomura, Shunji [1 ]
Kurusu, Tsutomu [1 ]
Ueda, Hiroshi [2 ,4 ]
Noguchi, So [3 ,4 ]
Ishiyama, Atsushi [4 ]
Urayama, Shinichi [5 ]
Fukuyama, Hidenao [5 ]
机构
[1] Toshiba Co Ltd, Yokohama, Kanagawa 2300045, Japan
[2] Okayama Univ, Okayama 7708530, Japan
[3] Hokkaido Univ, Sapporo, Hokkaido 0600814, Japan
[4] Waseda Univ, Tokyo 1698555, Japan
[5] Kyoto Univ, Kyoto 6068507, Japan
来源
SUPERCONDUCTOR SCIENCE & TECHNOLOGY | 2016年 / 29卷 / 10期
关键词
ultra-high-field MRI; REBCO; conduction-cooled;
D O I
10.1088/0953-2048/29/10/104001
中图分类号
O59 [应用物理学];
学科分类号
摘要
A project on the development of REBa2Cu3O7-delta (REBCO) magnets for ultra-high-field magnetic resonance imaging (MRI) was started in 2013. Since REBCO-coated conductors feature high mechanical strength under tensile stress and high critical current density, use of REBCO coils would allow superconducting magnets to be made smaller and lighter than conventional ones. In addition, a conduction-cooled superconducting magnet is simpler to use than one cooled by a liquid helium bath because the operation and maintenance of the cryogenic system become simpler, without the need to handle cryogenic fluid. Superconducting magnets for MRI require homogeneous, stable magnetic fields. The homogeneity of the magnetic field is highly dependent on the coil shape and position. Moreover, in REBCO magnets, the screening-current- induced magnetic field, which changes the magnetic field distribution of the magnet, is one of the critical issues. In order to evaluate the magnetic field homogeneity and the screening-current- induced magnetic field, a 1 T model magnet and some test coils were fabricated. From an evaluation of the 1 T model magnet, it was found that the main reason for magnetic field inhomogeneity was the tolerances in the z-axis positions of the coils, and therefore, it is important to control the gap between the single pancakes. In addition, we have already demonstrated the generation of an 8.27 T central magnetic field at 10 K with a small test coil. The screening-current-induced magnetic field was 0.43 T and was predictable by using an electromagnetic field simulation program. These results were reflected in the design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems. The magnet was composed of six main coils and two active shield coils. The total conductor length was 581 km, and the stored energy was 293 kJ. The field inhomogeneity was 24 ppm peak to peak and 3 ppm volume-root-mean-square (VRMS) for a 500 mm diameter spherical volume (DSV). The axial and radial 5 gauss line locations were less than 5 m and 4.2 m respectively.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Structural Design of a 9.4 T Whole-Body MRI Superconducting Magnet
    Dai, Yinming
    Wang, Qiuliang
    Wang, Chunzhong
    Li, Lankai
    Wang, Housheng
    Ni, Zhipeng
    Song, Shousen
    Chen, Shunzhong
    Zhao, Baozhi
    Wang, Hui
    Li, Yi
    Hu, Xinning
    Cui, Chunyan
    Cheng, Junsheng
    Lei, Yuanzhong
    Yan, Luguang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (03)
  • [2] Superconducting Shim Coils Design for the 9.4 T Whole-Body MRI Magnet
    Qu, Hongyi
    Wang, Wenchen
    Wu, Huafang
    Wang, Cong
    Wang, Yaohui
    Wang, Qiuliang
    Liu, Feng
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (02) : 1 - 10
  • [3] Quench protection design of a 9.4 T whole-body MRI superconducting magnet
    Chen, Shunzhong
    Li, Yi
    Dai, Yinming
    Lei, Yuanzhong
    Yan, Luguang
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2014, 497 : 49 - 53
  • [4] Thermal Analysis of the 4 K Cryostat Within a 1.5 T Conduction-Cooled Superconducting Magnet for Whole-Body MRI Application
    Qu, Hongyi
    Wu, Huafang
    Feng, Zhichao
    Xiao, Jing
    Chen, Qi
    Wang, Hui
    Wang, Qiuliang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (08)
  • [5] Passive shimming for the 9.4 T whole-body MRI superconducting magnet
    Wang, Wenchen
    Qu, Hongyi
    Wang, Yaohui
    Wang, Hui
    Cheng, Junsheng
    Wang, Cong
    Wu, Huafang
    Liu, Feng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (12):
  • [6] Preliminary Mechanical Analysis of a 9.4-T Whole-Body MRI Magnet
    Li, Lankai
    Cheng, Junsheng
    Ni, Zhipeng
    Wang, Housheng
    Dai, Yinming
    Wang, Qiuliang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (03)
  • [7] Numerical Analysis of Mechanical Behavior for a 9.4-T Whole-Body MRI Magnet
    Li, Lankai
    Cheng, Junsheng
    Cui, Chunyan
    Li, Yi
    Dai, Yinming
    Hu, Xinning
    Liu, Jianhua
    Wang, Lei
    Wang, Qiuliang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [8] Progress in the Development of Conduction-Cooled REBCO Magnets for Ultrahigh-Field MRI Systems
    Miyazaki, Hiroshi
    Iwai, Sadanori
    Uto, Tatsuro
    Otani, Yasumi
    Takahashi, Masahiko
    Tosaka, Taizo
    Tasaki, Kenji
    Nomura, Shunji
    Kurusu, Tsutomu
    Ueda, Hiroshi
    Noguchi, So
    Ishiyama, Atsushi
    Urayama, Shin-ichi
    Fukuyama, Hidenao
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [9] A simulation-based design study of superconducting zonal shim coil for a 9.4 T whole-body MRI magnet
    Kim, Geonyoung
    Choi, Kibum
    Park, Jeonghwan
    Bong, Uijong
    Bang, Jeseok
    Hahn, Seungyong
    PROGRESS IN SUPERCONDUCTIVITY AND CRYOGENICS, 2020, 22 (01): : 12 - 16
  • [10] Electromagnetic Structure Design of the Whole-Body 14 T MRI Magnet
    Xu, Aihua
    Wu, Kaihong
    Cai, Fuhai
    Zhang, Bo
    Tang, Zhipeng
    Shi, Yi
    Sang, Xiaohu
    Luo, Chunhui
    Shi, Kunju
    Shi, Dongli
    Ye, Sui
    Zhou, Jinyang
    Wu, Yu