Accurate measurement of the refractive indices of solids and liquids by the double-layer interferometer

被引:15
|
作者
Khashan, MA [1 ]
Nassif, AY [1 ]
机构
[1] Ain Shams Univ, Fac Sci, Dept Phys, Cairo, Egypt
关键词
D O I
10.1364/AO.39.005991
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The rings of equal inclination of the double-layer interferometer disappear in their common center if a plane-parallel glass plate is rotated inside one of the interferometer gaps that is filled with a liquid. Knowledge of the ring count and the rotated angle allows the refractive indices of both the rotated plate and the liquid to be found from a new analytical formula accurate to +/-0.0004. The experimental results for glass, distilled water, and methanol are fitted to the Sellmeier dispersion function to determine their quantum parameters such as the absorption wavelengths in the ultraviolet side of the spectrum and the atomic number densities contributing to these absorption bands. (C) 2000 Optical Society of America OCIS codes: 120.5710,260.2030, 120.3180.
引用
收藏
页码:5991 / 5997
页数:7
相关论文
共 50 条
  • [21] DIRECT MEASUREMENT OF VARIATION OF DOUBLE-LAYER REPULSION WITH DISTANCE
    MYSELS, KJ
    JONES, MN
    DISCUSSIONS OF THE FARADAY SOCIETY, 1966, (42): : 42 - &
  • [23] A NEW METHOD OF MEASURING OSCILLATOR-STRENGTHS USING THE DOUBLE-LAYER INTERFEROMETER
    KHASHAN, MA
    NASSIF, AY
    PHYSICA B & C, 1984, 124 (01): : 114 - 126
  • [24] A SCANNING MICHELSON INTERFEROMETER FOR THE MEASUREMENT OF THE CONCENTRATION AND TEMPERATURE DERIVATIVE OF THE REFRACTIVE-INDEX OF LIQUIDS
    BECKER, A
    KOHLER, W
    MULLER, B
    BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1995, 99 (04): : 600 - 608
  • [25] SIMPLE, RELIABLE, AND SENSITIVE INTERFEROMETER FOR THE MEASUREMENT OF THE REFRACTIVE-INDEX OF LIQUIDS AS A FUNCTION OF TEMPERATURE
    BEYSENS, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1979, 50 (04): : 509 - 510
  • [26] Highly accurate and numerically stable computations of double-layer coaxial waveguides
    Kubiczek, Krzysztof
    Kampik, Marian
    ENGINEERING COMPUTATIONS, 2019, 36 (04) : 1384 - 1399
  • [27] Double-layer resonant Brewster filters consisting of a homogeneous layer and a grating with equal refractive index
    Wang, Zhanshan
    Sang, Tian
    Zhu, Jingtao
    Wang, Li
    Wu, Yonggang
    Chen, Lingyan
    APPLIED PHYSICS LETTERS, 2006, 89 (24)
  • [28] Double slit interferometry to measure the EUV refractive indices of solids using high harmonics
    Wilson, Lucy A.
    Rossall, Andrew K.
    Wagenaars, Erik
    Cacho, Cephise M.
    Springate, Emma
    Turcu, I. C. Edmond
    Tallents, Greg J.
    APPLIED OPTICS, 2012, 51 (12) : 2057 - 2061
  • [29] The design of infrared double-layer refractive/diffractive hybrid Petzval optical system
    Fan Changjiang
    Wang Zhangqi
    Chen Ping
    Zhang Mei
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 4522 - 4525
  • [30] Structure design of refractive index sensor based on LPFG with double-layer coatings
    Gu, Zhengtian
    Luo, Tao
    Gao, Kan
    OPTICAL AND QUANTUM ELECTRONICS, 2013, 45 (07) : 761 - 768