Associations between continuous glucose monitoring-derived metrics and HbA1c in patients with type 2 diabetes mellitus

被引:5
|
作者
Kurozumi, Akira [1 ]
Okada, Yosuke [1 ,2 ]
Mita, Tomoya [3 ]
Wakasugi, Satomi [3 ]
Katakami, Naoto [4 ,5 ]
Yoshii, Hidenori [6 ]
Kanda, Kazuko [7 ]
Nishida, Keiko [8 ]
Mine, Shinichiro [9 ]
Tanaka, Yoshiya [1 ]
Gosho, Masahiko [10 ]
Shimomura, Iichiro [4 ]
Watada, Hirotaka [3 ]
机构
[1] Univ Occupat & Environm Hlth, Dept Internal Med 1, Sch Med, Yahatanishi Ku, 1-1 Iseigaoka, Kitakyushu, Fukuoka 8078555, Japan
[2] Hosp Univ Occupat & Environm Hlth, Clin Res Ctr, Yahatanishi Ku, 1-1 Iseigaoka, Kitakyushu, Fukuoka 8078555, Japan
[3] Juntendo Univ, Dept Metab & Endocrinol, Grad Sch Med, 2-1-1 Bunkyo Ku, Tokyo 1138421, Japan
[4] Osaka Univ, Dept Metab Med, Grad Sch Med, 2-2 Yamadaoka, Suita, Osaka, Japan
[5] Osaka Univ, Dept Metab & Atherosclerosis, Grad Sch Med, 2-2 Yamadaoka, Suita, Osaka 5650871, Japan
[6] Juntendo Tokyo Koto Geriatr Med Ctr, Dept Med Diabetol & Endocrinol, Koto Ku, Shinsuna 3-3-20, Tokyo 1360075, Japan
[7] Tobata Gen Hosp, Tobata Ku, 1-3-33 Fukuryugi, Kitakyushu, Fukuoka 8040025, Japan
[8] Nishida Keiko Diabet Clin, Yahatanishi Ku, 1-3-26 Mitsusadadai, Kitakyushu, Fukuoka 8070805, Japan
[9] Sasaki Hosp, Yahatanishi Ku, 9-36 Kisshoujirnachi, Kitakyushu, Fukuoka 8071114, Japan
[10] Univ Tsukuba, Fac Med, Dept Biostat, 1-1-1 Tennodai, Tsukuba, Ibaraki 3058575, Japan
关键词
Continuous glucose monitoring; Type 2 diabetes mellitus; Glucose variability; Hemoglobin A1c; RACIAL-DIFFERENCES; RANGE;
D O I
10.1016/j.diabres.2022.109836
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The aim of this study was to define the relationship between time in range (TIR) and hemoglobin A1c (HbA1c) levels in patients with type 2 diabetes mellitus (T2DM). Methods: The glycemic profile of 999 Japanese patients was analyzed with FreeStyle Libre Pro Continuous Glucose Monitoring (FLP-CGM) while they continued their prescribed glucose-lowering medications. FLP-CGM data recorded over 8 consecutive days were analyzed. Results: The regression model for HbA1c on TIR was HbA1c = 9.4966-0.0309 x TIR. The predicted HbA1c level for TIR of 70% was 7.33% and is higher than reports subjecting mostly T1DM. The TIR corresponding to HbA1c 7.0% was 80.64%. The patients with low TIR tended to have long duration of diabetes, used high dose of daily insulin, high body mass index, high HbA1c, liver dysfunction and high triglyceride. Relatively higher percentages of patients of this group used sulfonylureas, glucagon like peptide-1 receptor agonists and insulin. Conclusions: Our data showed predicted HbA1c corresponding to TIR is largely depends on study population, thus is not uniform. Our results provide new insights on the management of T2DM. However, caution should be exercised in extending the HbA1C-TIR relationship using FLP-CGM to any other sensors since there could be a risk of hypoglycemia in doing so.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] The relationship between HbA1c values and the occurrence of hypoglycemia as assessed by continuous glucose monitoring in patients with type 1 diabetes
    Tsujino, Daisuke
    Nishimura, Rimei
    Onda, Yoshiko
    Seo, Chiaki
    Ando, Kiyotaka
    Morimoto, Aya
    Utsunomiya, Kazunori
    [J]. DIABETOLOGY & METABOLIC SYNDROME, 2016, 8
  • [22] Relationship of continuous glucose monitoring-related metrics with HbA1c and residual β-cell function in Japanese patients with type 1 diabetes
    Babaya, Naru
    Noso, Shinsuke
    Hiromine, Yoshihisa
    Taketomo, Yasunori
    Niwano, Fumimaru
    Yoshida, Sawa
    Yasutake, Sara
    Kawabata, Yumiko
    Ikegami, Hiroshi
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [23] Relationship of continuous glucose monitoring-related metrics with HbA1c and residual β-cell function in Japanese patients with type 1 diabetes
    Naru Babaya
    Shinsuke Noso
    Yoshihisa Hiromine
    Yasunori Taketomo
    Fumimaru Niwano
    Sawa Yoshida
    Sara Yasutake
    Yumiko Kawabata
    Hiroshi Ikegami
    [J]. Scientific Reports, 11
  • [24] THE BENEFIT OF CONTINUOUS GLUCOSE MONITORING SYSTEM (CGMS-IPRO2) IN REDUCING HBA1C IN UNCONTROLLED TYPE 2 DIABETES MELLITUS PATIENTS
    Kannampilly, J. J.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A65 - A65
  • [25] Relationships between HbA1c and continuous glucose monitoring metrics of glycaemic control and glucose variability in a large cohort of children and adolescents with type 1 diabetes
    Piona, Claudia
    Marigliano, Marco
    Mozzillo, Enza
    Rosanio, Francesco
    Zanfardino, Angela
    Iafusco, Dario
    Maltoni, Giulio
    Zucchini, Stefano
    Piccinno, Elvira
    Delvecchio, Maurizio
    Maffeis, Claudio
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2021, 177
  • [26] Metrics for glycaemic control — from HbA1c to continuous glucose monitoring
    Boris P. Kovatchev
    [J]. Nature Reviews Endocrinology, 2017, 13 : 425 - 436
  • [27] Metrics for glycaemic control - from HbA1c to continuous glucose monitoring
    Kovatchev, Boris P.
    [J]. NATURE REVIEWS ENDOCRINOLOGY, 2017, 13 (07) : 425 - 436
  • [28] A LONGITUDINAL STUDY ON THE INTERRELATIONSHIPS BETWEEN HBA1C, FRUCTOSAMINE AND CONTINUOUS GLUCOSE MONITORING DERIVED MEAN BLOOD GLUCOSE IN TYPE 2 DM PATIENTS
    Ratnasingam, J.
    Lim, L. L.
    Paramasivam, S. Sunita
    Ibrahim, L.
    Vethakkan, S.
    Sthaneswar, P.
    Chan, S. P.
    Boon, A. T. T.
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2014, 106 : S91 - S91
  • [29] Relationship between HbA1c and daily fluctuations of blood glucose in patients with Type 1 diabetes mellitus
    Dundua, M
    Asatiani, N
    Kurashvili, R
    Shelestova, E
    Tsutskiridze, L
    [J]. DIABETOLOGIA, 2004, 47 : A346 - A346
  • [30] HbA1C, Glucose Variability and Hypoglycemia Risk in Patients With Type 1 Diabetes Mellitus
    Guelho, Daniela F.
    Barros, Luisa
    Baptista, Carla
    Paiva, Isabel
    Gouveia, Sofia
    Saraiva, Joana
    Moreno, Carolina
    Ruas, Luisa
    Carvalheiro, Manuela
    Carrilho, Francisco