Aptamer based Lateral Flow Assays for Rapid and Sensitive Detection of CKD marker Cystatin C

被引:4
|
作者
Natarajan, Satheesh [1 ]
Derosa, Maria [2 ]
Joseph, Jayaraj [3 ]
Shah, Malay Ilesh [1 ]
Karthik, Srinivasa [1 ]
机构
[1] IIT Madras, Healthcare Technol Innovat Ctr, Chennai, Tamil Nadu, India
[2] Carleton Univ, Chair Dept Chem, Carleton, ON, Canada
[3] IIT Madras, Dept Elect Engn, Chennai, Tamil Nadu, India
关键词
CysC; Aptamer; Alexafluor-647; LFA; Aptamer antibody pair based lateral flow assay;
D O I
10.1109/MeMeA52024.2021.9478684
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel aptamer-antibody pair-based lateral flow assay was designed to rapidly quantify Cystatin C (CysC). CysC is a small protein that can be expressed by all nucleated cells. It is rarely influenced by factors other than Glomerular filtration rate (GFR), an indicator of renal function chronic kidney diseases (CID). That makes it a reliable biomarker for the measurement of the GFR. Aptamers bind specifically to the target molecules, it is less expensive, more stable, and lack immunogenicity. The aptamers became a valuable tool in clinical diagnosis and made them a great alternative to antibodies. In this study, we designed and developed an aptamer- antibody pair-based quantitative lateral flow assay for the CysC quantification in the human sample. A highly sensitive and specific CysC sensor was achieved by conjugating CysC selective aptamers to the organic dye Alexafluor-647. When CysC molecules are present in the sample, they form a complex with the designed aptamers to bind, especially with the CysC antibody immobilized on the lateral flow assay strip's test zone. Important parameters that influence the sensitivity in lateral flow assay, such as the concentration of aptamers in the conjugation pad, were evaluated to give the optimum assay performance. The assay was precise and has a limit of detection of 0.013 mu g/mu l was shown better than the antibody-based kit. In summary, the resulting LFA aptamers-based sensor provides a rapid, sensitive, cost-effective point of care sensor for CysC detection in human samples.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Osmoprocessor for enabling highly sensitive biomarker detection via lateral flow assays
    Lai, James
    Chen, Sheng-You
    Wu, Abe
    Lunde, Ruby
    TISSUE ENGINEERING PART A, 2022, 28 : 315 - 315
  • [22] Fluorescence-based lateral flow assays for rapid oral fluid roadside detection of cannabis use
    Plouffe, Brian D.
    Murthy, Shashi K.
    ELECTROPHORESIS, 2017, 38 (3-4) : 501 - 506
  • [23] Rapid and Specific Detection of Bacillus cereus Using Phage Protein-Based Lateral Flow Assays
    Le Brun, Gregoire
    Nuytten, Manon
    Leprince, Audrey
    Glinel, Karine
    Gillis, Annika
    Mahillon, Jacques
    Raskin, Jean-Pierre
    ACS APPLIED BIO MATERIALS, 2024, 7 (11): : 7292 - 7305
  • [24] Lateral flow assays for hormone detection
    Khelifa, Leena
    Hu, Yubing
    Jiang, Nan
    Yetisen, Ali K.
    LAB ON A CHIP, 2022, 22 (13) : 2451 - 2475
  • [25] Rapid and sensitive detection of zearalenone in corn using SERS-based lateral flow immunosensor
    Yin, Limei
    You, Tianyan
    El-Seedi, Hesham R.
    El-Garawani, Islam M.
    Guo, Zhiming
    Zou, Xiaobo
    Cai, Jianrong
    FOOD CHEMISTRY, 2022, 396
  • [26] Development of a sensitive lateral flow immunoassay for the rapid detection of butralin in fruits
    Kou, Shuai
    Liu, Liqiang
    Song, Shanshan
    Kuang, Hua
    Xu, Chuanlai
    Wu, Xiaoling
    FOOD CONTROL, 2024, 162
  • [27] A rapid and sensitive lateral flow immunoassay (LFIA) for the detection of gluten in foods
    Hnasko, Robert M.
    Jackson, Eric S.
    Lin, Alice, V
    Haff, Ronald P.
    McGarvey, Jeffery A.
    FOOD CHEMISTRY, 2021, 355
  • [28] Carbon nanotube-based lateral flow biosensor for sensitive and rapid detection of DNA sequence
    Qiu, Wanwei
    Xu, Hui
    Takalkar, Sunitha
    Gurung, Anant S.
    Liu, Bin
    Zheng, Yafeng
    Guo, Zebin
    Baloda, Meenu
    Baryeh, Kwaku
    Liu, Guodong
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 367 - 372
  • [29] Aptamer Lateral Flow Assays for Ultrasensitive Detection of β-Conglutin Combining Recombinase Polymerase Amplification and Tailed Primers
    Jauset-Rubio, Miriam
    Svobodova, Marketa
    Mairal, Teresa
    McNeil, Calum
    Keegan, Neil
    El-Shahawi, Mohammad S.
    Bashammakh, Abdulaziz S.
    Alyoubi, Abdulrahman O.
    O'Sullivan, Ciara K.
    ANALYTICAL CHEMISTRY, 2016, 88 (21) : 10701 - 10709
  • [30] Simultaneous and Rapid Detection of Glucose and Insulin: Coupling Enzymatic and Aptamer-Based Assays
    Nandhakumar, Ponnusamy
    Djassemi, Omeed
    Raucci, Ada
    Chang, An-Yi
    Cheung, Christopher
    Dugas, Yuma
    Silberman, Julia
    Morales-Fermin, Sofia
    Sandhu, Samar S.
    Reynoso, Maria
    Saha, Tamoghna
    Cinti, Stefano
    Wang, Joseph
    ANALYTICAL CHEMISTRY, 2024, 96 (47) : 18806 - 18814