Optimum parameters of tuned liquid column damper for suppressing pitching vibration of an undamped structure

被引:24
|
作者
Xue, SD [1 ]
Ko, JM
Xu, YL
机构
[1] Beijing Polytech Univ, Inst Civil & Architectural Engn, Beijing 100022, Peoples R China
[2] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Kowloon, Hong Kong, Peoples R China
关键词
D O I
10.1006/jsvi.2000.2947
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In order to evaluate the control performance of the tuned liquid column damper in suppressing pitching vibration of structures, an optimal parametric study of the damper is carried out for an undamped structure. The structure is assumed to be subjected to harmonic excitation in the analysis. The optimum tuning ratio (or the optimum liquid length) and the optimum head loss coefficient of the damper are determined using Den Hartog's method. The analytical formulas of the optimum TLCD parameters for the undamped structure are derived. The optimum peak amplitudes for the structure and the liquid are also obtained. Based on the developed analytical formulas, the practical solution procedures for finding the optimum parameters are proposed. The presented example indicates that the optimum TLCD parameters can be easily calculated from the developed formulas. With the help of this study, the understanding of TLCD behavior with respect to its optimum parameters is enhanced. (C) 2000 Academic Press.
引用
下载
收藏
页码:639 / 653
页数:15
相关论文
共 50 条
  • [21] Wind-induced interaction of a non-uniform tuned liquid column damper and a structure in pitching motion
    Wu, Jong-Cheng
    Wang, Yen-Po
    Lee, Chien-Liang
    Liao, Pei-Hsuan
    Chen, Yi-Hsuan
    ENGINEERING STRUCTURES, 2008, 30 (12) : 3555 - 3565
  • [22] Optimum absorber parameters for tuned liquid column dampers
    Yalla, SK
    Kareem, A
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2000, 126 (08): : 906 - 915
  • [23] Transforming Method of Torsional Tuned Liquid Column Damper-Eccentric Structure to Torsional Tuned Mass Damper-Eccentric Structure for Vibration Control
    Chuan, Fu
    STRUCTURAL ENGINEERING INTERNATIONAL, 2021, 31 (02) : 295 - 303
  • [24] Optimal design of tuned liquid column damper inerter for vibration control
    Di Matteo, Alberto
    Masnata, Chiara
    Adam, Christoph
    Pirrotta, Antonina
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2022, 167
  • [25] Optimal design of tuned liquid column damper inerter for vibration control
    Di Matteo, Alberto
    Masnata, Chiara
    Adam, Christoph
    Pirrotta, Antonina
    Mechanical Systems and Signal Processing, 2022, 167
  • [26] VIBRATION CONTROL OF SUPER TALL BUILDINGS BY TUNED LIQUID COLUMN DAMPER
    Farshidianfar, Anooshirvan
    Oliazadeh, Pouria
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, 2010,
  • [27] OPTIMUM DESIGN OF TUNED LIQUID COLUMN DAMPER FOR HIGH-RISE BUILDING
    Sokol, M.
    Lamperova, K.
    Venglar, M.
    Hernandez Carrasco, L. H.
    ENGINEERING MECHANICS 2017, 2017, : 898 - 901
  • [28] Characteristics of multiple tuned liquid column dampers in suppressing structural vibration
    Gao, H
    Kwok, KSC
    Samali, B
    ENGINEERING STRUCTURES, 1999, 21 (04) : 316 - 331
  • [29] Investigation of an improved tuned liquid column gas damper for the vertical vibration control
    Liu, Kaifang
    Shi, Qingxuan
    Liu, Yanhui
    Liu, Lulu
    Zhou, Fulin
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2023, 196
  • [30] Investigation on a Shallow Water Annular Tuned Liquid Damper for Suppressing Vibration of Wind Tower
    Zhang, Youlin
    Li, Huaxiang
    Xu, Yiqing
    SCIENCE OF MAKING TORQUE FROM WIND (TORQUE 2020), PTS 1-5, 2020, 1618