Comparison of control strategies for shunt active power filters in three-phase four-wire systems

被引:389
|
作者
Milanes Montero, Maria Isabel [1 ]
Romero Cadaval, Enrique [1 ]
Barrero Gonzalez, Fermin [1 ]
机构
[1] Univ Extremadura, Dept Elect & Electromech Engn, Badajoz 639798, Spain
关键词
active filtering; i(d) - i(q) method; perfect harmonic cancellation method; p-q theory; reference current extraction; unity power factor method (UPF);
D O I
10.1109/TPEL.2006.886616
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Strategies for extracting the three-phase reference currents for shunt active power filters are compared, evaluating their performance under different source and load conditions with the new IEEE Standard 1459 power definitions. The study was applied to a three-phase four-wire system in order to include imbalance. Under balanced and sinusoidal voltages, harmonic cancellation and reactive power compensation can be attained in all the methods. However, when the voltages are distorted and/or unbalanced, the compensation capabilities are not equivalent, with some strategies unable to yield an adequate solution when the mains voltages are not ideal. Simulation and experimental results are included.
引用
收藏
页码:229 / 236
页数:8
相关论文
共 50 条
  • [11] Sliding mode control of three-phase four-wire shunt active power filter
    Mendalek, N.
    2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, : 422 - 426
  • [12] A Control Strategy for a Three-Phase Four-Wire Shunt Active Filter
    Ferreira, Filipe
    Monteiro, Luis
    Afonso, Joao L.
    Couto, Carlos
    IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, : 360 - 365
  • [13] Novel deadbeat control scheme for three-phase four-wire active power filters
    Huazhong University of Science and Technology, Wuhan 430074, China
    不详
    不详
    Dianli Xitong Zidonghue, 2007, 19 (59-63):
  • [14] A shunt active filter control for one-phase and three-phase four-wire systems
    Dell'Aquila, A
    Lecci, A
    ISIE 2002: PROCEEDINGS OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-4, 2002, : 1301 - 1305
  • [15] Three-phase Four-wire Shunt Active Power Filter Based on DSP
    Chen, Lezhu
    Jia, Zhoujun
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 2, 2010, : 383 - 386
  • [16] Control Strategy of DC Voltage in Three-Phase Four-Wire Shunt Active Power Filter
    Wei, Xueliang
    Liang, Zhishan
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 2036 - +
  • [17] A Linear Decoupling Control for a PWM Three-Phase Four-Wire Shunt Active Power Filter
    Kanaan, H. Y.
    Georges, S.
    Mendalek, N.
    Hayek, A.
    Al-Haddad, K.
    2008 IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, VOLS 1 AND 2, 2008, : 589 - +
  • [18] Performance Analysis of Three-phase Four-wire Shunt Active Power Filter
    Vanjani, Harsha
    Choudhury, U. K.
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON RELIABILTY, OPTIMIZATION, & INFORMATION TECHNOLOGY (ICROIT 2014), 2014, : 496 - 500
  • [19] High Precision Control Strategy for Three-Phase Four-Wire Shunt Active Power Filter
    Xu, Qunwei
    Zhong, Xiaojian
    Yao, Wenxi
    Chen, Guozhu
    2014 IEEE 23RD INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2014, : 509 - 514
  • [20] An efficient control system of shunt active power filter in three-phase four-wire power system
    School of Electricity and Information Engineering, Beijing University of Civil Engineering and Architecture, Beijing, China
    不详
    Int. J. Control Autom., 9 (275-290):