High resolution low dose scattered gamma-ray tomography

被引:3
|
作者
Thoe, RS
机构
[1] V Division, Lawrence Livermore Natl. Laboratory, Livermore
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1996年 / 67卷 / 01期
关键词
D O I
10.1063/1.1146557
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper discusses a technique which uses Compton scattered gamma radiation to obtain high contrast, highly spatially resolved, three-dimensional images in optically opaque objects. A highly desirable property of this technology is that this method allows the acquisition of radiographs without the necessity of placing the object between the source and detector. This paper describes a prototype apparatus which is capable of obtaining images with a spatial resolution of about 1 mm at a depth of 25 mm in steel of normal density with the source and detector both on the same side of the object. Some modeling calculations, reconstruction algorithms, and data verifying the performance of this technique will be presented as well as details of how the efficiency and throughput of this system could be increased by over two orders of magnitude. (C) 1996 American Institute of Physics.
引用
收藏
页码:89 / 101
页数:13
相关论文
共 50 条
  • [21] HIGH-RESOLUTION GAMMA-RAY SPECTROSCOPY AT ILL
    HOYLER, F
    BORNER, HG
    JOLIE, J
    ULBIG, S
    WILLIAMS, A
    PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, 1992, 28 : 419 - 420
  • [22] NEW HIGH-RESOLUTION GAMMA-RAY MONOCHROMATOR
    MOREH, R
    JACOB, I
    MOURAD, R
    NUCLEAR INSTRUMENTS & METHODS, 1975, 127 (02): : 193 - 203
  • [23] HIGH ENERGY GAMMA-RAY DETECTOR WITH GOOD RESOLUTION
    DALLY, EB
    HOFSTADTER, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (05): : 658 - +
  • [24] High resolution gamma-ray spectroscopy with a radioactive beam
    Catford, WN
    Mohammadi, S
    Regan, PH
    Purry, CS
    Gelletly, W
    Walker, PM
    Gyapong, GJ
    Simpson, J
    Warner, DD
    Davinson, T
    Neal, R
    Page, RD
    Shotter, AC
    Hibbert, IM
    Wadsworth, R
    Forbes, SA
    Bruce, AM
    Thwaites, C
    Thirolf, P
    VanDuppen, P
    Galster, W
    Ninane, A
    Vervier, J
    Decrock, P
    Huyse, M
    Szerypo, J
    Wauters, J
    NUCLEAR PHYSICS A, 1997, 616 (1-2) : C303 - C310
  • [25] GAMMA-RAY BURST OBSERVATIONS BY THE HEAO-3 HIGH-RESOLUTION GAMMA-RAY SPECTROMETER
    WHEATON, WA
    LING, JC
    MAHONEY, WA
    RIEGLER, GR
    JACOBSON, AS
    AIP CONFERENCE PROCEEDINGS, 1982, (77) : 55 - 65
  • [26] Compact high-resolution gamma-ray computed tomography system for multiphase flow studies
    Bieberle, A.
    Nehring, H.
    Berger, R.
    Arlit, M.
    Haerting, H-U.
    Schubert, M.
    Hampel, U.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (03):
  • [27] A HIGH RESOLUTION (N,N'GAMMA) GAMMA-RAY SPECTROMETER SYSTEM
    WILLIAMS, GH
    TUCKER, WE
    ASHE, JB
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (06): : 873 - &
  • [28] Development of a high energy resolution and wide dose rate range portable gamma-ray spectrometer
    Wang, Yichao
    Feng, Changqing
    Zhao, Maoyuan
    Shan, Chenyu
    Liu, Feng
    Lei, Qingxin
    Zhou, Ziheng
    Liu, Shubin
    APPLIED RADIATION AND ISOTOPES, 2023, 192
  • [29] THE INDUSTRIAL APPLICATION OF LOW-COST GAMMA-RAY TOMOGRAPHY
    MACCUAIG, N
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1991, 33 (03): : 111 - 114
  • [30] Low-resolution gamma-ray measurements of uranium enrichment
    Sprinkle, JK
    Christiansen, A
    Cole, R
    Collins, ML
    Hsue, ST
    Knepper, PL
    McKown, TO
    Siebelist, R
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) : 1525 - 1528