High resolution low dose scattered gamma-ray tomography

被引:3
|
作者
Thoe, RS
机构
[1] V Division, Lawrence Livermore Natl. Laboratory, Livermore
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1996年 / 67卷 / 01期
关键词
D O I
10.1063/1.1146557
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper discusses a technique which uses Compton scattered gamma radiation to obtain high contrast, highly spatially resolved, three-dimensional images in optically opaque objects. A highly desirable property of this technology is that this method allows the acquisition of radiographs without the necessity of placing the object between the source and detector. This paper describes a prototype apparatus which is capable of obtaining images with a spatial resolution of about 1 mm at a depth of 25 mm in steel of normal density with the source and detector both on the same side of the object. Some modeling calculations, reconstruction algorithms, and data verifying the performance of this technique will be presented as well as details of how the efficiency and throughput of this system could be increased by over two orders of magnitude. (C) 1996 American Institute of Physics.
引用
收藏
页码:89 / 101
页数:13
相关论文
共 50 条
  • [1] CALIBRATION OF THE HIGH AND LOW RESOLUTION GAMMA-RAY SPECTROMETERS
    Luca, Aurelian
    Neacsu, Beatris
    Antohe, Andrei
    Sahagia, Maria
    ROMANIAN REPORTS IN PHYSICS, 2012, 64 (04) : 968 - 976
  • [2] Design of a high-resolution gamma-ray detector module for tomography applications
    Bieberle, A.
    Kronenberg, J.
    Schleicher, E.
    Hampel, U.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (02): : 668 - 675
  • [3] Temperature control design for a high-resolution gamma-ray tomography detector
    Bieberle, Andre
    Schleicher, Eckhard
    Hampel, Uwe
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (01):
  • [4] Void measurement using high-resolution gamma-ray computed tomography
    Bieberle, Andre
    Hoppe, Dietrich
    Schleicher, Eckhard
    Hampel, Uwe
    NUCLEAR ENGINEERING AND DESIGN, 2011, 241 (06) : 2086 - 2092
  • [5] High-resolution spectroscopy of gamma-ray bursts with the transient gamma-ray spectrometer
    Kurczynski, P
    Palmer, D
    Seifert, H
    Teegarden, BJ
    Gehrels, N
    Cline, TL
    Ramaty, R
    Hurley, K
    Madden, NW
    Pehl, RH
    ASTROPHYSICAL JOURNAL, 2000, 543 (01): : 77 - 89
  • [6] High-resolution gamma-ray spectroscopy
    H. G. Börner
    M. Jentschel
    Physics of Atomic Nuclei, 2001, 64 : 1011 - 1014
  • [7] High-resolution gamma-ray spectroscopy
    Börner, HG
    Jentschel, A
    PHYSICS OF ATOMIC NUCLEI, 2001, 64 (06) : 1011 - 1014
  • [8] High Resolution Gamma-Ray Spectroscopy at GANIL
    de France, G.
    XXXVI BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2014, 1625 : 10 - 16
  • [9] Low and high-resolution gamma-ray spectroscopy for the characterization of uranium contamination
    Salvador, F.
    Marchais, T.
    Perot, B.
    Allinei, P. -G.
    Morales, F.
    Gueton, O.
    Venara, J.
    Cuozzo, M.
    Fichet, P.
    Mayet, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1065
  • [10] THE SCINTILLATION COUNTER AS A LOW RESOLUTION GAMMA-RAY SPECTROMETER
    PRINGLE, RW
    ROULSTON, KI
    TAYLOR, HW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1950, 21 (03): : 216 - 218