Using permalloy based planar hall effect sensors to capture and detect superparamagnetic beads for lab on a chip applications

被引:12
|
作者
Volmer, Marius [1 ]
Avram, Marioara [2 ]
机构
[1] Transilvania Univ Brasov, Elect Engn & Appl Phys Dept, Brasov 500036, Romania
[2] Natl Inst Res & Dev Microtechnol, Bucharest 72996, Romania
关键词
Magnetic sensor; Planar Hall effect; Anisotropic magnetoresistance; Lab-on-a-Chip; NANOPARTICLES; FIELD;
D O I
10.1016/j.jmmm.2014.10.172
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Experimental studies have been carried out on planar Hall effect (PHE) sensors used to detect magnetic nanoparticles employed as labels for biodetection applications. Disk shaped sensors, 1 mm diameter, were structured on Permalloy film, 20 nm thick. To control the sensor magnetisation state and thus the held sensitivity and linearity, a DC biasing held has been applied parallel to the driving current. Maghemite nanoparticles (10 nm) functionalised with Polyethylene glycol (PEG) 6000 were immobilised over the sensor surface using particular magnetisation state and applied magnetic fields. In order to obtain a higher response from the magnetic nanoparticles, it was used a detection setup which allows the application of magnetic fields larger than 100 Oe but avoiding saturation of the PHE signal. Based On this setup, two field scanning methods are presented in this paper. During our experiments, low magnetic moments, of about 1.87 x 10(-5) emu, have been easily detected. This value corresponds to a mass of 9.35 mu g of maghemite nanoparticles functionalised with PEG 6000. The results suggest that this type of structure is feasible for building low cost micrometer sized PHE sensors to be used for high-resolution bio sensing applications. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:481 / 487
页数:7
相关论文
共 48 条
  • [41] Discharge-Based Pressure Sensors for High-Temperature Applications Using Three-Dimensional and Planar Microstructures
    Wright, Scott A.
    Gianchandani, Yogesh B.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2009, 18 (03) : 736 - 743
  • [42] Placement of Hall Effect Sensors in Permanent Magnet Motors Featuring Quasi-Halbach Array Configuration to Detect the Rotor Position Using Orthogonal Flux
    Khalesidoost, Sina
    Vignesh Sankarraman, Sri
    Gardner, Matthew C.
    IEEE Transactions on Magnetics, 2024, 60 (11)
  • [43] Quench detection using Hall sensors in high-temperature superconducting CORC®-based cable-in-conduit-conductors for fusion applications
    Weiss, J. D.
    Teyber, R.
    Marchevsky, M.
    van der Laan, D. C.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2020, 33 (10):
  • [44] Bragg grating based biochemical sensor using submicron Si/SiO2 waveguides for lab-on-a-chip applications: a novel design
    Tripathi, Saurabh Mani
    Kumar, Arun
    Marin, Emmanuel
    Meunier, Jean-Pierre
    APPLIED OPTICS, 2009, 48 (23) : 4562 - 4567
  • [45] An Accurate Torque Control of Permanent Magnet Brushless Motor using Low-Resolution Hall-Effect Sensors for Light Electric Vehicle Applications
    Huang, Ming-Shi
    Chen, Chin-Hao
    Chou, Hsin-Hung
    Chen, Guen-Zheng
    Tsai, Wen-Ko
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 175 - 179
  • [46] Microfluidic chip-based protein capture from human whole blood using octadecyl (C18) silica beads for nucleic acid analysis from large volume samples
    Wen, Jian
    Guillo, Christelle
    Ferrance, Jerome P.
    Landers, James P.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1171 (1-2) : 29 - 36
  • [47] Rotor Position Estimation Using Harmonic-Decomposition Complex-Coefficient Filter-Based PLL for PMSM With Switch Hall-Effect Sensors
    Xin, Zhuang-Zhuang
    Wang, Jia-Jun
    Zhao, Hong-Jiang
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2024, 12 (02) : 2249 - 2259
  • [48] A built-in technique for measuring substrate and power-supply digital switching noise using PMOS-based differential sensors and a waveform sampler in system-on-chip applications
    Iorga, Cosmin
    Lu, Yi-Chang
    Dutton, Robert W.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (06) : 2330 - 2337